31 research outputs found

    日本人変形性股関節症例における近位大腿骨髄腔形態のコンピューター支援設計法を用いた三次元的解析

    Get PDF
    取得学位:博士(医学), 学位授与番号:医博乙第1526号, 学位授与年月日:平成12年11月1日, 学位授与年:200

    Recombinant human FGF-2 for the treatment of early-stage osteonecrosis of the femoral head: TRION, a single-arm, multicenter, Phase II trial

    Get PDF
    Aim: This study aimed to evaluate the 2-year outcomes from a clinical trial of recombinant human FGF-2 (rhFGF-2) for osteonecrosis of the femoral head (ONFH). Patients & methods: Sixty-four patients with nontraumatic, precollapse and large ONFHs were percutaneously administered with 800 μg rhFGF-2 contained in gelatin hydrogel. Setting the end point of radiological collapse, we analyzed the joint preservation period of the historical control. Changes in two validated clinical scores, bone regeneration and safety were evaluated. Results: Radiological joint preservation time was significantly higher in the rhFGF-2 group than in the control group. The ONFHs tended to improve to smaller ONFHs. The postoperative clinical scores significantly improved. Thirteen serious adverse events showed recovery. Conclusion: rhFGF-2 treatment increases joint preservation time with clinical efficacy, radiological bone regeneration and safety

    Stem subsidence of polished and rough double-taper stems: In vitro mechanical effects on the cement-bone interface

    Get PDF
    Background and purpose Many clinical reports have indicated that polished hip stems show better clinical results than rough stems of the same geometry. It is still unknown, however, what the mechanical effects are of different surface finishes on the cement at the cement-bone interface. We compared mechanical effects in an in vitro cemented hip arthroplasty model

    Japanese Orthopaedic Association Hip Disease Evaluation Questionnaire (JHEQ): a patient-based evaluation tool for hip-joint disease. The Subcommittee on Hip Disease Evaluation of the Clinical Outcome Committee of the Japanese Orthopaedic Association

    Get PDF
    AbstractBackgroundThe Japanese Orthopaedic Association Hip Score is widely used in Japan, but this tool is designed to reflect the viewpoint of health-care providers rather than that of patients. In gauging the effect of medical therapies in addition to clinical results, it is necessary to assess quality of life (QOL) from the viewpoint of patients. However, there is no tool evaluating QOL for Japanese patients with hip-joint disease.MethodsWith the aim of more accurately classifying QOL for Japanese patients with hip-joint disease, we prepared a questionnaire with 58 items for the survey derived from 464 opinions obtained from approximately 100 Japanese patients with hip-joint disease and previously devised evaluation criteria. In the survey, we collected information on 501 cases, and 402 were subjected to factor analysis. From this, we formulated three categories—movement, mental, and pain—each comprising 7 items, for a total of 21 items to be used as evaluation criteria for hip-joint function.ResultsThe Cronbach’s α coefficients for the three categories were 0.93, 0.93, and 0.95, respectively, indicating the high reliability of the evaluation criteria. The 21 items included some related to the Asian lifestyle, such as use of a Japanese-style toilet and rising from the floor, which are not included in other evaluation tools.ConclusionsThis self-administered questionnaire may become a useful tool in the evaluation of not only Japanese patients, but also of members of other ethnic groups who engage in deep flexion of the hip joint during daily activities

    Occult fracture of the femoral neck associated with extensive osteonecrosis of the femoral head: A case report

    Get PDF
    Introduction: Although the subchondral portion of the femoral head is a common site for collapse in osteonecrosis of the femoral head (ONFH), femoral-neck fracture rarely occurs during the course of ONFH. We report a case of occult insufficiency fracture of the femoral neck without conditions predisposing to insufficiency fractures, occurring in association with ONFH. Presentation of case: We report a case of occult fracture of the femoral neck due to extensive ONFH in a 60-year-old man. No abnormal findings suggestive of ONFH were identified on radiographs, and the fracture occurred spontaneously without any trauma or unusual increase in activity. The patient’s medical history, age, and good bone quality suggested ONFH as a possible underlying cause. Contrast-enhanced magnetic resonance imaging was useful in determining whether the fracture was caused by ONFH or was instead a simple insufficiency fracture caused by steroid use. Discussion: The patient was treated with bipolar hemiarthroplasty, but if we had not suspected ONFH as a predisposing condition, the undisplaced fracture might have been treated by osteosynthesis, and this would have led to nonunion or collapse of the femoral head. To avoid providing improper treatment, clinicians should consider ONFH as a predisposing factor in pathologic fractures of the femoral neck. Conclusion: ONFH should be included in the differential diagnosis of insufficiency fracture of the femoral neck

    Early MRI and intraoperative findings in rapidly destructive osteoarthritis of the hip: A case report

    Get PDF
    Introduction: The pathophysiology of rapidly destructive hip osteoarthritis (OA) of the hip is still unclear. Also, there have been only few reports on the initial stage of the disease. We report a case of an initial-stage rapidly destructive hip OA, documented by magnetic resonance imaging and intraoperative findings. Presentation of case: A 77-year-old woman reported left hip pain without any antecedent trauma. Initial radiographs showed no obvious abnormality. After 4 months of conservative therapy, radiographs showed progressive joint-space narrowing and T1-weighted magnetic resonance images revealed a bone-marrow edema pattern not only on the femoral head but also on the lateral side of the acetabulum. Then during total hip arthroplasty, we found extensive inversion of the anterosuperior portion of the acetabular labrum, and the location was mostly consistent with the bone-marrow edema lesions in the femoral head and acetabulum. Discussion: Several theories for the etiology of rapidly destructive hip OA have been proposed, including idiopathic chondrolysis, abnormal immunoreaction, intra-articular deposition of hydroxyapatite crystals, and subchondral insufficiency fracture. One of the reasons rapidly destructive hip OA is still considered idiopathic is the lack of reports regarding the initial stage of the disease. Our report is the first to demonstrate magnetic resonance imaging for initial-stage disease with intraoperative findings before collapse of the femoral head. Conclusion: Inversion of the acetabular labrum may be a mechanism of rapidly destructive hip OA

    Relationship between the Surface Roughness of Material and Bone Cement: An Increased “Polished” Stem May Result in the Excessive Taper-Slip

    No full text
    Although some reports suggest that taper-slip cemented stems may be associated with a higher periprosthetic femoral fractures rate than composite-beam cemented stems, few studies have focused on the biomaterial effect of the polished material on the stem–cement interface. The purpose of this study was to investigate the relationship between surface roughness of materials and bone cement. Four types of metal discs—cobalt-chromium-molybdenum alloy (CoCr), stainless steel alloy 316 (SUS), and two titanium alloys (Ti-6Al-4V and Ti-15Mo-5Zr-3Al)—were prepared. Five discs of each material were produced with varying degrees of surface roughness. In order to evaluate surface wettability, the contact angle was measured using the sessile drop method. A pin was made using two bone cements and the frictional coefficient was assessed with a pin-on-disc test. The contact angle of each metal increased with decreasing surface roughness and the surface wettability of metal decreased with higher degrees of polishing. With a surface roughness of Ra = 0.06 μm and moderate viscosity bone cement, the frictional coefficient was significantly lower in CoCr than in SUS (p = 0.0073). In CoCr, the low adhesion effect with low frictional coefficient may result in excessive taper-slip, especially with the use of moderate viscosity bone cement
    corecore