30 research outputs found

    Differences in image density adjustment parameters on the image matching accuracy of a floor-mounted kV X-ray image-guided radiation therapy system

    Get PDF
    This study aimed to investigate the effect of two different image density adjustment parameters on the results of image matching at six degrees of freedom using radiographic images generated by the ExacTrac X-ray system in brain stereotactic radiosurgery (SRS). This study comprised 32 patients who underwent brain SRS at our hospital from January 2020 to December 2020. In this study, (1) the default parameter (an image density parameter between “tissue” and “bone”) was an image density parameter for digitally reconstructed radiograph (DRR) generation used at many facilities, and (2) the bone parameter was the steepest contrast parameter used at our hospital. Of the 32 patients, 24 (75%) had a couch angle of 0.5 mm or more in the translational direction or 0.5° or more in the rotational direction, and 10 (31%) had a couch angle of 1.0 mm or more in the translational direction or 1.0° or more in the rotational direction. Among the 131 cases of all couch angles, 46 (35%) cases had a translational direction of 0.5 mm or more or a rotational direction of 0.5° or more, and 15 (11%) had a translational direction of 1.0 mm or more or a rotational direction of 1.0° or more. The results of this study indicate the usefulness of using appropriate DRR parameters for each case, rather than using the default settings. The use of appropriate DRR parameters can lead to accurate position matching results, leading to fewer image-guided radiation therapy shots and a lower imaging dose

    Analysis of prostate intensity- and volumetric-modulated arc radiation therapy planning quality with PlanIQTM

    Get PDF
    Purpose: The purpose of this study was to assess the quality of treatment planning using the PlanIQTM software and to investigate whether it is possible to improve the quality of treatment planning using the “Feasibility dose-volume histogram (DVH)TM” implemented in the PlanIQTM software. Methods: Using the PlanIQTM software, we retrospectively analyzed the learning curve regarding the quality of the treatment plans for 148 patients of prostate intensity-modulated radiation therapy and volumetric-modulated radiation therapy performed at our institution over the past eight years. We also sought to examine the possibility of improving treatment planning quality by re-planning in 47 patients where the quality of the target dose and the dose limits for organs at risk (OARs) were inadequate. The re-planning treatment plans referred to the Feasibility DVHTM implemented in the PlanIQTM software and modified the treatment planning system based on the target dose and OAR constraints. Results: Analysis of the learning curve of the treatment plans quality using PlanIQTM software retrospectively showed a trend of improvement in the treatment plan quality from year to year. The improvement in the treatment plans quality was more influenced by dose reduction in the OARs than by target coverage. In all cases where re-planning was performed, the improvement in the treatment plan's quality resulted in a better treatment plan than the one adopted for delivery to patients in the clinical plan. Conclusions: The PlanIQTM provided insights into the quality of the treatment plans at our institution and identified problems and areas for improvement in the treatment plans, allowing for the development of appropriate treatment plans for specific patients

    Development of a high-resolution two-dimensional detector-based dose verification system for tumor-tracking irradiation in the CyberKnife system

    Get PDF
    We aim to evaluate the basic characteristics of SRS MapCHECK (SRSMC) for CyberKnife (CK) and establish a dose verification system using SRSMC for the tumor-tracking irradiation for CK. The field size and angular dependence of SRSMC were evaluated for basic characterization. The output factors (OPFs) and absolute doses measured by SRSMC were compared with those measured using microDiamond and microchamber detectors and those calculated by the treatment planning system (TPS). The angular dependence was evaluated by comparing the SRSMC with a microchamber. The tumor-tracking dose verification system consists of SRSMC and a moving platform. The doses measured using SRSMC were compared with the doses measured using a microchamber and radiochromic film. The OPFs and absolute doses of SRSMC were within ±3.0% error for almost all field sizes, and the angular dependence was within ±2.0% for all incidence angles. The absolute dose errors between SRSMC and TPS tended to increase when the field size was smaller than 10 mm. The absolute doses of the tumor-tracking irradiation measured using SRSMC and those measured using a microchamber agreed within 1.0%, and the gamma pass rates of SRSMC in comparison with those of the radiochromic film were greater than 95%. The basic characteristics of SRSMC for CK presented acceptable results for clinical use. The results of the tumor-tracking dose verification system realized using SRSMC were equivalent to those of conventional methods, and this system is expected to contribute toward improving the efficiency of quality control in many facilities

    前立腺IMRTおよびVMATに及ぼす直腸ガスの線量影響

    Get PDF
    Purpose: In this study, we compared the dose impact of the heterogeneity caused by rectal gas using two methods of treatment planning for intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT). Materials and Methods: In addition to the structure set used for the standard treatment plan, we created a structure set for evaluation for each patient. The structure sets for evaluation that were created were transferred to the same iso-center as the respective treatment plans for IMRT and VMAT that were to become the standard. The values were then re-calculated. Results: During the standard prostatic IMRT and VMAT treatment planning, all the subjects met the dose restrictions in place at our hospital. Dose restrictions were fulfilled in the treatment plans for evaluation, excluding those with a clinical target volume (CTV) of V100% and planning target volume (PTV) of D95 when the rectum was excluded. However, in treatment plans for evaluation, IMRT was shown to have a higher concordance rate with standard treatment plans than VMAT. Conclusion: If rectal gas is present during either IMRT or VMAT, a dose decrease will occur in relation to CTV and PTV, suggesting that a plan does not eliminate adverse effects on organs at risk

    Differences between professionals in treatment planning for patients with stage III lung cancer using treatment-planning QA software

    Get PDF
    Background: The quality of treatment planning for stage III non-small cell lung cancer varies within and between facilities due to the different professions involved in planning. Dose estimation parameters were calculated using a feasibility dose-volume histogram (FDVH) implemented in the treatment planning quality assurance software PlanIQ. This study aimed to evaluate differences in treatment planning between occupations using manual FDVH-referenced treatment planning to identify their characteristics. Materials and methods: The study included ten patients with stage III non-small cell lung cancer, and volumetric-modulated arc therapy was used as the treatment planning technique. Fifteen planners, comprising five radiation oncologists, five medical physicists, and five radiological technologists, developed treatment strategies after referring to the FDVH. Results: Medical physicists had a higher mean dose at D98% of the planning target volume (PTV) and a lower mean dose at D2% of the PTV than those in other occupations. Medical physicists had the lowest irradiation lung volumes (V5 Gy and V13 Gy) compared to other professions, and radiation oncologists had the lowest V20 Gy and mean lung dose. Radiological technologists had the highest irradiation volumes for dose constraints at all indexes on the normal lung volume. Conclusions: The quality of the treatment plans developed in this study differed between occupations due to their background expertise, even when an FDVH was used as a reference. Therefore, discussing and sharing knowledge and treatment planning techniques among professionals is essential to determine the optimal treatment plan for each facility and patient

    Influence of Age on the Mating Behaviour of the Braconid Wasp, Apanteles glomeratus L.

    No full text

    Predicting the complexity of head-and-neck volumetric-modulated arc therapy planning using a radiation therapy planning quality assurance software

    No full text
    Background/Aim: The more complex the treatment plan, the higher the possibility of errors in dose verification. Recently, a treatment planning quality assurance (QA) software (PlanIQ) with a function to objectively evaluate the quality of volumetric-modulated arc therapy (VMAT) treatment plans by scoring and calculating the ideal dose-volume histogram has been marketed. This study aimed to assess the association between the scores of ideal treatment plans identified using PlanIQ and the results of dose verification and to investigate whether the results of dose verification can be predicted based on the complexity of treatment plans. Materials and methods: Dose verification was performed using an ionization chamber dosimeter, a radiochromic film, and a three-dimensional dose verification system, Delta4 PT. Correlations between the ideal treatment plan scores obtained by PlanIQ and the results of the absolute dose verification and dose distribution verification were obtained, and it was examined whether dose verifications could be predicted from the complexity of the treatment plans. Results: Even when the score from the ideal treatment plan was high, the results of absolute dose verification and dose distribution verification were sometimes poor. However, even when the score from the ideal treatment plan was low, the absolute volume verification and dose distribution verification sometimes yielded good results. Conclusions: Treatment plan complexity can be determined in advance from the ideal treatment plan score calculated by PlanIQ. However, it is difficult to predict the results of dose verification using an ideal treatment plan

    Accuracy of image guidance using free-breathing cone-beam computed tomography for stereotactic lung radiotherapy.

    No full text
    Movement of the target object during cone-beam computed tomography (CBCT) leads to motion blurring artifacts. The accuracy of manual image matching in image-guided radiotherapy depends on the image quality. We aimed to assess the accuracy of target position localization using free-breathing CBCT during stereotactic lung radiotherapy. The Vero4DRT linear accelerator device was used for the examinations. Reference point discrepancies between the MV X-ray beam and the CBCT system were calculated using a phantom device with a centrally mounted steel ball. The precision of manual image matching between the CBCT and the averaged intensity (AI) images restructured from four-dimensional CT (4DCT) was estimated with a respiratory motion phantom, as determined in evaluations by five independent operators. Reference point discrepancies between the MV X-ray beam and the CBCT image-guidance systems, categorized as left-right (LR), anterior-posterior (AP), and superior-inferior (SI), were 0.33 ± 0.09, 0.16 ± 0.07, and 0.05 ± 0.04 mm, respectively. The LR, AP, and SI values for residual errors from manual image matching were -0.03 ± 0.22, 0.07 ± 0.25, and -0.79 ± 0.68 mm, respectively. The accuracy of target position localization using the Vero4DRT system in our center was 1.07 ± 1.23 mm (2 SD). This study experimentally demonstrated the sufficient level of geometric accuracy using the free-breathing CBCT and the image-guidance system mounted on the Vero4DRT. However, the inter-observer variation and systematic localization error of image matching substantially affected the overall geometric accuracy. Therefore, when using the free-breathing CBCT images, careful consideration of image matching is especially important
    corecore