1,873 research outputs found

    Anodized aluminium pressure sensitive paint: effect of paint application technique

    Get PDF
    The porous surface of the Anodized Aluminium Pressure Sensitive Paint (AA-PSP) is what differentiates it from conventional sol–gel based PSPs, leading to a faster response time of the paint. The objective of the current study is to examine the effect of the paint application technique, i.e., whether the AA substrate is dipped or sprayed, on the pressure and temperature sensitivity. A more practical procedure for preparing the AA samples is also presented. Scanning Electron Microscope (SEM) images are acquired together with the calibration of the AA-PSP at various temperatures and pressures to determine the effectiveness of each application technique. The results revealed that the AA sample which was dipped in the PSP solution shows a higher pressure sensitivity than the sprayed one. The SEMs show that spraying leads to the covering up of the micropores created on the surface and undermining the benefit of anodization

    EVALUATION OF EXHAUST GAS FROM BIO-DIESEL FUEL ENGINE

    Full text link
    Joint Research on Environmental Science and Technology for the Eart

    Effect of Impurities in Description of Surface Nanobubbles

    Get PDF
    Surface nanobubbles emerging at solid-liquid interfaces of submerged hydrophobic surfaces show extreme stability and very small (gas-side) contact angles. In a recent study Ducker (W. A. Ducker, Langmuir 25, 8907 (2009).) conjectured that these effects may arise from the presence of impurities at the air-water interface of the nanobubbles. In this paper we present a quantitative analysis of this hypothesis by estimating the dependence of the contact angle and the Laplace pressure on the fraction of impurity coverage at the liquid-gas interface. We first develop a general analytical framework to estimate the effect of impurities (ionic or non-ionic) in lowering the surface tension of a given air-water interface. We then employ this model to show that the (gas-side) contact angle and the Laplace pressure across the nanobubbles indeed decrease considerably with an increase in the fractional coverage of the impurities, though still not sufficiently small to account for the observed surface nanobubble stability. The proposed model also suggests the dependencies of the Laplace pressure and the contact angle on the type of impurity

    Highly c-axis-oriented AlN film using MOCVD for 5GHz-band FBAR filter

    Get PDF
    科研費報告書収録論文(課題番号:14205053/研究代表者:坪内和夫/ソフトウェア無線端末用超低消費電力GHz帯RF DSPの開発

    Ground-state electric quadrupole moment of 31Al

    Full text link
    Ground-state electric quadrupole moment of 31Al (I =5/2+, T_1/2 = 644(25) ms) has been measured by means of the beta-NMR spectroscopy using a spin-polarized 31Al beam produced in the projectile fragmentation reaction. The obtained Q moment, |Q_exp(31Al)| = 112(32)emb, are in agreement with conventional shell model calculations within the sd valence space. Previous result on the magnetic moment also supports the validity of the sd model in this isotope, and thus it is concluded that 31Al is located outside of the island of inversion.Comment: 5 page

    Variations of the cephalic vein anterior to the clavicle in humans

    Get PDF
    Background: Clinicians should understand that jugulocephalic vein (JCV) variants may be occasionally found. This study aims to classify JCV variants and obtain their frequency.   Materials and methods: We investigated anatomical variants of the cephalic vein in 55 human cadavers during a gross anatomy course at our medical school.   Results: The percentage of JCVs that pass through the anterior part of the clavicle and anastomose to the jugular vein as per previous studies and our study was 2–5%. Five cases with anastomosis between the cephalic and external jugular veins that pass through the anterior part of the clavicle were found. The courses were classified into 1A, 1B, 2A, and 2B. Type 1 extends beyond the clavicle and anastomoses with the external jugular vein. Type 2 follows the same course as type 1, but anastomoses with the subclavian vein. Subtype A does not have a branch that anastomoses with the axillary vein, whereas subtype B does. We encountered two cases of type 1A and three of type 1B.   Conclusions: Four anatomical variants of the cephalic vein around the clavicle were identified. Clinicians’ knowledge of these variants is expected to decrease possible complications if venous access via the cephalic vein is needed
    corecore