94 research outputs found

    Genauigkeit eines bildfreien Navigationssystemes für die Hüftpfannenimplantation – eine anatomische Studie

    Get PDF
    The position of the acetabular cup is of decisive importance for. the function of a total hip replacement (THR). Using the conventional surgical technique, correct placement of the cup often fails due to a lack of information about pelvic tilt. With CT-based and fluoroscopically-assisted navigation procedures the accuracy of implantation has been significantly improved. However, additional radiation exposure, high cost and the increased time requirement have hampered the acceptance of these techniques. The present anatomical study evaluates the accuracy of an alternative procedure-image-free navigation. This method requires little extra effort, does not substantially delay surgery, and needs no additional imaging. Press-fit cups were implanted in 10 human cadaveric hips with the help of the image-free navigation system, and the position of the cups was checked intraoperatively with a CT-based navigation system and postoperatively by computed tomography. All cups were implanted within the targeted safe zone with an average inclination of 44degrees (range 40degrees-48degrees, SABW 2.7degrees) and an average anteversion of 18degrees (range 12-24degrees, SABW 4.1degrees). Analysis of accuracy of the image-free navigation software revealed only a small, clinically tolerable deviation in cup anteversion and cup inclination in comparison with the CT-based navigation system and the post operative CT scans. The evaluated image-free navigation system appears to be a practicable and reliable alternative to the computer-assisted implantation of acetabular cups in total hip arthroplasty

    Genauigkeit eines bildfreien Navigationssystemes für die Hüftpfannenimplantation – eine anatomische Studie

    Get PDF
    The position of the acetabular cup is of decisive importance for. the function of a total hip replacement (THR). Using the conventional surgical technique, correct placement of the cup often fails due to a lack of information about pelvic tilt. With CT-based and fluoroscopically-assisted navigation procedures the accuracy of implantation has been significantly improved. However, additional radiation exposure, high cost and the increased time requirement have hampered the acceptance of these techniques. The present anatomical study evaluates the accuracy of an alternative procedure-image-free navigation. This method requires little extra effort, does not substantially delay surgery, and needs no additional imaging. Press-fit cups were implanted in 10 human cadaveric hips with the help of the image-free navigation system, and the position of the cups was checked intraoperatively with a CT-based navigation system and postoperatively by computed tomography. All cups were implanted within the targeted safe zone with an average inclination of 44degrees (range 40degrees-48degrees, SABW 2.7degrees) and an average anteversion of 18degrees (range 12-24degrees, SABW 4.1degrees). Analysis of accuracy of the image-free navigation software revealed only a small, clinically tolerable deviation in cup anteversion and cup inclination in comparison with the CT-based navigation system and the post operative CT scans. The evaluated image-free navigation system appears to be a practicable and reliable alternative to the computer-assisted implantation of acetabular cups in total hip arthroplasty

    Importance of Preoperative Imaging in Acetabular Revision Surgery - A Case Report

    Get PDF
    Acetabular defects, particularly as a result of protrusion of acetabular components into the hemipelvis, may cause serious complications during revision procedures as a result of iatrogenic injury to surrounding anatomical structures. In these challenging cases, we advocate the utilisation of preoperative three dimensional imaging. MRI and CT- imaging offer superior understanding of the three-dimensional quality of bony defects and the relationship of implants to important anatomical structures. Appropriate preoperative planning may also prevent major complications during the removal of the pre-existing hardware, prior to re-implantation of implants. Potential complications include injury of nerves, blood vessels and other intrapelvic structures

    Minimally invasive and computer-navigated total hip arthroplasty: a qualitative and systematic review of the literature

    Get PDF
    ABSTRACT: BACKGROUND: Both minimally invasive surgery (MIS) and computer-assisted surgery (CAS) for total hip arthroplasty (THA) have gained popularity in recent years. We conducted a qualitative and systematic review to assess the effectiveness of MIS, CAS and computer-assisted MIS for THA. METHODS: An extensive computerised literature search of PubMed, Medline, Embase and OVIDSP was conducted. Both randomised clinical trials and controlled clinical trials on the effectiveness of MIS, CAS and computer-assisted MIS for THA were included. Methodological quality was independently assessed by two reviewers. Effect estimates were calculated and a best-evidence synthesis was performed. RESULTS: Four high-quality and 14 medium-quality studies with MIS THA as study contrast, and three high-quality and four medium-quality studies with CAS THA as study contrast were included. No studies with computer-assisted MIS for THA as study contrast were identified. Strong evidence was found for a decrease in operative time and intraoperative blood loss for MIS THA, with no difference in complication rates and risk for acetabular outliers. Strong evidence exists that there is no difference in physical functioning, measured either by questionnaires or by gait analysis. Moderate evidence was found for a shorter length of hospital stay after MIS THA. Conflicting evidence was found for a positive effect of MIS THA on pain in the early postoperative period, but that effect diminished after three months postoperatively. Strong evidence was found for an increase in operative time for CAS THA, and limited evidence was found for a decrease in intraoperative blood loss. Furthermore, strong evidence was found for no difference in complication rates, as well as for a significantly lower risk for acetabular outliers. CONCLUSIONS: The results indicate that MIS THA is a safe surgical procedure, without increases in operative time, blood loss, operative complication rates and component malposition rates. However, the beneficial effect of MIS THA on functional recovery has to be proven. The results also indicate that CAS THA, though resulting in an increase in operative time, may have a positive effect on operative blood loss and operative complication rates. More importantly, the use of CAS results in better positioning of acetabular component of the prosthesis

    Prostatic sarcoma after treatment of rectal cancer

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The relationship between radiation exposure for treatment of cancer and occurrence of a second primary cancer at the irradiated site is well known. This phenomenon is however rare in prostate.</p> <p>Case presentation</p> <p>A 75-year-old farmer was treated for rectal cancer with preoperative 45 Gy of radiotherapy and abdominoperineal resection. Four years later he developed symptoms of bladder outlet obstruction and acute urinary retention. He underwent a transurethral resection of the prostate. Histological examination of the removed prostate tissue and immunohistochemistry revealed it to be a poorly differentiated sarcoma.</p> <p>Conclusion</p> <p>We believe this to be the first reported case of radiation-induced sarcoma following radiotherapy treatment for rectal cancer. Since radiotherapy plays a pivotal role in the contemporary treatment of rectal adenocarcinoma, it is relevant to be aware of the potential long-term carcinogenic complications of radiotherapy of the pelvis.</p

    Effectiveness of computer-navigated minimally invasive total hip surgery compared to conventional total hip arthroplasty: design of a randomized controlled trial

    Get PDF
    BACKGROUND: Moderate to severe osteoarthrosis is the most common indication for Total Hip Arthroplasty (THA). Minimally Invasive Total Hip Surgery (MIS) and computer-navigated surgery were introduced several years ago. However, the literature lacks well-designed studies that provide evidence of superiority of computer-navigated MIS over a conventional THA technique. Hence, the purpose of this study is to compare (cost)effectiveness of computer-navigated MIS with a conventional technique for THA. It is our hypothesis that computer-navigated MIS will lead to a quicker recovery during the early postoperative period (3 months), and to an outcome at least as good 6 months postoperatively. We also hypothesize that computer-navigated MIS leads to fewer perioperative complications and better prosthesis positioning. Furthermore, cost advantages of computer-navigated MIS over conventional THA technique are expected. METHODS/DESIGN: A cluster randomized controlled trial will be executed. Patients between the ages of 18 and 75 admitted for primary cementless unilateral THA will be included. Patients will be stratified using the Charnley classification. They will be randomly allocated to have computer-navigated MIS or conventional THA technique. Measurements take place preoperatively, perioperatively, and 6 weeks and 3 and 6 months postoperatively. Degree of limping (gait analysis), self-reported functional status and health-related quality of life (questionnaires) will be assessed preoperatively as well as postoperatively. Perioperative complications will be registered. Radiographic evaluation of prosthesis positioning will take place 6 weeks postoperatively. An evaluation of costs within and outside the healthcare sector will focus on differences in costs between computer-navigated MIS and conventional THA technique. DISCUSSION: Based on studies performed so far, few objective data quantifying the risks and benefits of computer-navigated MIS are available. Therefore, this study has been designed to compare (cost) effectiveness of computer-navigated MIS with a conventional technique for THA. The results of this trial will be presented as soon as they become available
    • …
    corecore