29 research outputs found

    Biochemical evidence for the interaction of regulatory subunit of cAMP-dependent protein kinase with IDA (Inter-DFG-APE) region of catalytic subunit

    Get PDF
    AbstractTo explore the structural basis required for the holoenzyme formation of cAMP-dependent protein kinase, we have prepared rabbit anti-peptide antibodies that can block the holoenzyme formation without affecting the catalytic activity of the enzyme. The antibodies were raised against a specific site in the catalytic (C)-subunit, termed IDA (Inter-DFG-APE) region, which lies between the kinase subdomains VII and VIII. Although the C-subunit immunoprecipitated with anti-IDA antibodies could not form a stable complex with regulatory (R)-subunit, it was still susceptible to inhibition by the R-subunit or by PKI, a specific inhibitor peptide containing a pseudosubstrate site. These results indicate that there exists an IDA regionmediated interaction between the R- and C-subunits, which is distinct from that mediated through the substrate site and substrate binding site. In accordance with this idea, association of synthetic IDA peptides with the R-subunit was directly demonstrated by resonance mirror analysis. The calculated association constants of IDA peptides were high enough to suggest a possible involvement of the IDA region in the initial step of holoenzyme formation

    A Prospective Comparison of EUS-Guided FNA Using 25-Gauge and 22-Gauge Needles

    Get PDF
    Background and Aims. There are limited data on the differences in diagnostic yield between 25-gauge and 22-gauge EUS-FNA needles. This prospective study compared the difference in diagnostic yield between a 22-gauge and a 25-gauge needle when performing EUS-FNA. Methods. Forty-three patients with intraluminal or extraluminal mass lesions and/or lymphadenopathy were enrolled prospectively. EUS-FNA was performed for each mass lesion using both 25- and 22-gauge needles. The differences in accuracy rate, scoring of needle visibility, ease of puncture and quantity of obtained specimen were evaluated. Results. The overall accuracy of 22- and 25-gauge needle was similar at 81% and 76% respectively (N.S). Likewise the visibility scores of both needles were also similar. Overall the quantity of specimen obtained higher with the 22-gauge needle (score: 1.64 vs. P < .001). However the 25-gauge needle was significantly superior to the 22-gauge needle in terms of ease of puncture (score: 1.9 vs. 1.29, P < .001) and in the quantity of specimen in the context of pancreatic mass EUS-FNA (score: 1.8 vs. 1.58, P < .05). Conclusion. The 22-gauge and 25-gauge needles have similar overall diagnostic yield. The 25-gauge needle appeared superior in the subset of patients with hard lesions and pancreatic masses

    Novel Subset of CD8α +

    No full text
    corecore