4 research outputs found

    Impact of stalk on directly driven inertial confinement fusion implosions

    Get PDF
    Low-mode asymmetries have emerged as one of the primary challenges to achieving high-performing inertial confinement fusion (ICF) implosions. In direct-drive ICF, an important potential seed of such asymmetries is the capsule stalk mount, the impact of which has remained a contentious question. In this paper, we describe the results from an experiment on the OMEGA laser with intentional offsets at varying angles to the capsule stalk mount, which clearly demonstrates the impact of the stalk mount on implosion dynamics. The angle between stalk and offset is found to significantly impact observables. Specifically, a larger directional flow is observed in neutron spectrum measurements when the offset is toward rather than away from the stalk, while an offset at 42° to the stalk gives minimal directional flow but still generates a large flow field in the implosion. No significant directional flow is seen due to stalk only. Time-integrated x-ray images support these flow observations. A trend is also seen in implosion yield, with lower yield obtained for offsets with a smaller angle than with a larger angle toward the stalk. Radiation hydrodynamic simulations using 2D DRACO and 2D/3D Chimera not including the stalk mount and using 2D xRAGE including the stalk mount are brought to bear on the data. The yield trend, the minimal directional flow with stalk only, and the larger flow enhancement observed with the offset toward the stalk are all reproduced in the xRAGE simulations. The results strongly indicate that the stalk impact must be considered and mitigated to achieve high-performing implosions

    X-ray-imaging spectrometer (XRIS) for studies of residual kinetic energy and low-mode asymmetries in inertial confinement fusion implosions at OMEGA (invited)

    No full text
    A system of x-ray imaging spectrometer (XRIS) has been implemented at the OMEGA Laser Facility and is capable of spatially and spectrally resolving x-ray self-emission from 5 to 40 keV. The system consists of three independent imagers with nearly orthogonal lines of sight for 3D reconstructions of the x-ray emission region. The distinct advantage of the XRIS system is its large dynamic range, which is enabled by the use of tantalum apertures with radii ranging from 50 μm to 1 mm, magnifications of 4 to 35×, and image plates with any filtration level. In addition, XRIS is capable of recording 1–100’s images along a single line of sight, facilitating advanced statistical inference on the detailed structure of the x-ray emitting regions. Properties such as P0 and P2 of an implosion are measured to 1% and 10% precision, respectively. Furthermore, T e can be determined with 5% accuracy. </jats:p
    corecore