28 research outputs found
Vortex Plastic Flow, , Deep in the Bose Glass and Mott-Insulator Regimes
We present simulations of flux-gradient-driven superconducting vortices
interacting with strong columnar pinning defects as an external field is
quasi-statically swept from zero through a matching field . We
analyze several measurable quantities, including the local flux density , magnetization , critical current , and the
individual vortex flow paths. We find a significant change in the behavior of
these quantities as the local flux density crosses , and quantify it
for many microscopic pinning parameters. Further, we find that for a given pin
density can be enhanced by maximizing the distance between the pins
for .Comment: 4 pages, 4 PostScript Figure
Suppression of matching field effects by splay and pinning energy dispersion in YBa_2Cu_3O_7 with columnar defects
We report measurements of the irreversible magnetization M_i of a large
number of YBa_2Cu_3O_7 single crystals with columnar defects (CD). Some of them
exhibit a maximum in M_i when the density of vortices equals the density of
tracks, at temperatures above 40K. We show that the observation of these
matching field effects is constrained to those crystals where the orientational
and pinning energy dispersion of the CD system lies below a certain threshold.
The amount of such dispersion is determined by the mass and energy of the
irradiation ions, and by the crystal thickness. Time relaxation measurements
show that the matching effects are associated with a reduction of the creep
rate, and occur deep into the collective pinning regime.Comment: 7 pages, 5 figures, submitted to Phys. Rev.
Properties of the Bose glass phase in irradiated superconductors near the matching field
Structural and transport properties of interacting localized flux lines in
the Bose glass phase of irradiated superconductors are studied by means of
Monte Carlo simulations near the matching field B_Phi, where the densities of
vortices and columnar defects are equal. For a completely random columnar pin
distribution in the xy-plane transverse to the magnetic field, our results show
that the repulsive vortex interactions destroy the Mott insulator phase which
was predicted to occur at B = B_Phi. On the other hand, for ratios of the
penetration depth to average defect distance lambda/d <= 1, characteristic
remnants of the Mott insulator singularities remain visible in experimentally
accessible quantities as the magnetization, the bulk modulus, and the
magnetization relaxation, when B is varied near B_Phi. For spatially more
regular disorder, e.g., a nearly triangular defect distribution, we find that
the Mott insulator phase can survive up to considerably large interaction range
\lambda/d, and may thus be observable in experiments.Comment: RevTex, 17 pages, eps files for 12 figures include
A simplified (modified) Duke Activity Status Index (M-DASI) to characterise functional capacity: A secondary analysis of the Measurement of Exercise Tolerance before Surgery (METS) study
Background
Accurate assessment of functional capacity, a predictor of postoperative morbidity and mortality, is essential to improving surgical planning and outcomes. We assessed if all 12 items of the Duke Activity Status Index (DASI) were equally important in reflecting exercise capacity.
Methods
In this secondary cross-sectional analysis of the international, multicentre Measurement of Exercise Tolerance before Surgery (METS) study, we assessed cardiopulmonary exercise testing and DASI data from 1455 participants. Multivariable regression analyses were used to revise the DASI model in predicting an anaerobic threshold (AT) >11 ml kg −1 min −1 and peak oxygen consumption (VO 2 peak) >16 ml kg −1 min −1, cut-points that represent a reduced risk of postoperative complications.
Results
Five questions were identified to have dominance in predicting AT>11 ml kg −1 min −1 and VO 2 peak>16 ml.kg −1min −1. These items were included in the M-DASI-5Q and retained utility in predicting AT>11 ml.kg −1.min −1 (area under the receiver-operating-characteristic [AUROC]-AT: M-DASI-5Q=0.67 vs original 12-question DASI=0.66) and VO 2 peak (AUROC-VO2 peak: M-DASI-5Q 0.73 vs original 12-question DASI 0.71). Conversely, in a sensitivity analysis we removed one potentially sensitive question related to the ability to have sexual relations, and the ability of the remaining four questions (M-DASI-4Q) to predict an adequate functional threshold remained no worse than the original 12-question DASI model. Adding a dynamic component to the M-DASI-4Q by assessing the chronotropic response to exercise improved its ability to discriminate between those with VO 2 peak>16 ml.kg −1.min −1 and VO 2 peak<16 ml.kg −1.min −1.
Conclusions
The M-DASI provides a simple screening tool for further preoperative evaluation, including with cardiopulmonary exercise testing, to guide perioperative management