3 research outputs found
Status of the CRESST Dark Matter Search
The CRESST experiment aims for a detection of dark matter in the form of
WIMPs. These particles are expected to scatter elastically off the nuclei of a
target material, thereby depositing energy on the recoiling nucleus. CRESST
uses scintillating CaWO4 crystals as such a target. The energy deposited by an
interacting particle is primarily converted to phonons which are detected by
transition edge sensors. In addition, a small fraction of the interaction
energy is emitted from the crystals in the form of scintillation light which is
measured in coincidence with the phonon signal by a separate cryogenic light
detector for each target crystal. The ratio of light to phonon energy permits
the discrimination between the nuclear recoils expected from WIMPs and events
from radioactive backgrounds which primarily lead to electron recoils. CRESST
has shown the success of this method in a commissioning run in 2007 and, since
then, further investigated possibilities for an even better suppression of
backgrounds. Here, we report on a new class of background events observed in
the course of this work. The consequences of this observation are discussed and
we present the current status of the experiment.Comment: Proceedings of the 13th International Workshop on Low Temperature
Detectors, 4 pages, 3 figure
Composite CaWO4 Detectors for the CRESST-II Experiment
CRESST-II, standing for Cryogenic Rare Events Search with Superconducting
Thermometers phase II, is an experiment searching for Dark Matter. In the LNGS
facility in Gran Sasso, Italy, a cryogenic detector setup is operated in order
to detect WIMPs by elastic scattering off nuclei, generating phononic lattice
excitations and scintillation light. The thermometers used in the experiment
consist of a tungsten thin-film structure evaporated onto the CaWO4 absorber
crystal. The process of evaporation causes a decrease in the scintillation
light output. This, together with the need of a big-scale detector production
for the upcoming EURECA experiment lead to investigations for producing
thermometers on smaller crystals which are glued onto the absorber crystal. In
our Run 31 we tested composite detectors for the first time in the Gran Sasso
setup. They seem to produce higher light yields as hoped and could provide an
additional time based discrimination mechanism for low light yield clamp
events.Comment: Proceedings of the Thirteenth International Workshop on Low
Temperature Detectors 4 pages, 9 figure
Cryogenic light detectors with enhanced performance for rare event physics
We have developed and tested a new way of coupling bolometric light detectors to scintillating crystal bolometers based upon simply resting the light detector on the crystal surface, held in position only by gravity. This straightforward mounting results in three important improvements: (1) it decreases the amount of non-active materials needed to assemble the detector, (2) it substantially increases the light collection efficiency by minimizing the light losses induced by the mounting structure, (3) and it enhances the thermal signal induced in the light detector thanks to the extremely weak thermal link to the thermal bath.
We tested this new technique with a 16 cm Ge light detector with thermistor readout sitting on the surface of a large TeO bolometer. The light collection efficiency was increased by greater than 50% compared to previously tested alternative mountings. We obtained a baseline energy resolution on the light detector of 20 eV RMS that, together with increased light collection, enabled us to obtain the best vs discrimination ever obtained with massive TeO crystals. At the same time we achieved rise and decay times of 0.8 and 1.6 ms, respectively. This superb performance meets all of the requirements for the CUPID (CUORE Upgrade with Particle IDentification) experiment, which is a 1-ton scintillating bolometer follow up to CUORE