259 research outputs found

    Enzyme-linked immunosorbent assay for urinary albumin at low concentrations

    Get PDF
    We describe an enzyme-linked immunosorbent assay (ELISA) for urinary albumin. It requires only commercially available reagents, can detect as little as 16 micrograms of albumin per liter, and analytical recovery ranges from 92 to 116%. The assay is simple, rapid, and inexpensive. Albumin excretion was 6.2 (SD 4.1) mg/24 h in healthy subjects (n = 40), 14.7 (SD 7.2) mg/24 h in albumin-test-strip-negative Type I diabetics (n = 11), and 19.7 (SD 16.2) mg/24 h in patients with essential hypertension (n = 12)

    Measurements and Modeling of Transient Blood Flow Perturbations Induced by Brief Somatosensory Stimulation

    Get PDF
    Proper interpretation of BOLD fMRI and other common functional imaging methods requires an understanding of neurovascular coupling. We used laser speckle-contrast optical imaging to measure blood-flow responses in rat somatosensory cortex elicited by brief (2 s) forepaw stimulation. Results show a large increase in local blood flow speed followed by an undershoot and possible late-time oscillations. The blood flow measurements were modeled using the impulse response of a simple linear network, a four-element windkessel. This model yielded excellent fits to the detailed time courses of activated regions. The four-element windkessel model thus provides a simple explanation and interpretation of the transient blood-flow response, both its initial peak and its late-time behavior

    A Model for Transient Oxygen Delivery in Cerebral Cortex

    Get PDF
    Popular hemodynamic brain imaging methods, such as blood oxygen-level dependent functional magnetic resonance imaging (BOLD fMRI), would benefit from a detailed understanding of the mechanisms by which oxygen is delivered to the cortex in response to brief periods of neural activity. Tissue oxygen responses in visual cortex following brief visual stimulation exhibit rich dynamics, including an early decrease in oxygen concentration, a subsequent large increase in concentration, and substantial late-time oscillations (“ringing”). We introduce a model that explains the full time-course of these observations made by Thompson et al. (2003). The model treats oxygen transport with a set of differential equations that include a combination of flow and diffusion in a three-compartment (intravascular, extravascular, and intracellular) system. Blood flow in this system is modeled using the impulse response of a lumped linear system that includes an inertive element; this provides a simple biophysical mechanism for the ringing. The model system is solved numerically to produce excellent fits to measurements of tissue oxygen. The results give insight into the dynamics of cerebral oxygen transfer, and can serve as the starting point to understand BOLD fMRI measurements

    Low expression of the putative tumour suppressor spinophilin is associated with higher proliferative activity and poor prognosis in patients with hepatocellular carcinoma

    Get PDF
    BACKGROUND: Spinophilin, a multifunctional intracellular scaffold protein, is reduced in certain types of cancer and is regarded as a novel putative tumour suppressor protein. However, the role of spinophilin in hepatocellular carcinoma (HCC) has never been explored before. METHODS: In this study, we determined for the first time the expression pattern of spinophilin in human HCC by immunohistochemistry and quantitative reverse transcriptase–PCR analysis. In addition, we performed immunohistochemical analysis of p53, p14(ARF) and the proliferation marker Ki-67. Kaplan–Meier curves and multivariate Cox proportional models were used to study the impact on clinical outcome. Small interfering RNA (siRNA) was used to silence spinophilin and to explore the effects of reduced spinophilin expression on cellular growth. RESULTS: In our study, complete loss of spinophilin immunoreactivity was found in 44 of 104 HCCs (42.3%) and reduced levels were found in an additional 37 (35.6%) cases. After adjusting for other prognostic factors, multivariate Cox regression analysis identified low expression of spinophilin as an independent prognostic factor with respect to disease-free (hazard ratio (HR)=1.8; 95% confidence interval (CI)=1.04–3.40; P=0.043) and cancer-specific survival (HR=2.0; CI=1.1–3.8; P=0.025). Reduced spinophilin expression significantly correlated with higher Ki-67 index in HCC (P=0.014). Reducing spinophilin levels by siRNA induced a higher cellular growth rate and increased cyclin D2 expression in tumour cells (P<0.05). CONCLUSION: This is the first study of the expression pattern and distribution of spinophilin in HCC. According to our data, the loss of spinophilin is associated with higher proliferation and might be useful as a prognostic marker in patients with HCC

    Influence of strenuous exercise on albumin excretion

    Get PDF
    Renal albumin excretion rate was 7.3 mg/24 h (SEM 0.5, range 0.6-21.0) in 66 healthy subjects. This rate increased markedly during and shortly after strenuous exercise on a bicycle ergometer (before: 5.5 +/- 0.6 micrograms/min; during and just after: 16.9 +/- 2.2 micrograms/min; P less than 0.001; n = 30). However, albumin excretion/24 h was not significantly higher during 24 h with a period of strenuous exercise than during 24 h without such exercise (10.3 +/- 0.9 mg/24 h vs 8.5 +/- 0.7 mg/24 h)

    Cortical depth dependent functional responses in humans at 7T: improved specificity with 3D GRASE

    Get PDF
    Ultra high fields (7T and above) allow functional imaging with high contrast-to-noise ratios and improved spatial resolution. This, along with improved hardware and imaging techniques, allow investigating columnar and laminar functional responses. Using gradient-echo (GE) (T2* weighted) based sequences, layer specific responses have been recorded from human (and animal) primary visual areas. However, their increased sensitivity to large surface veins potentially clouds detecting and interpreting layer specific responses. Conversely, spin-echo (SE) (T2 weighted) sequences are less sensitive to large veins and have been used to map cortical columns in humans. T2 weighted 3D GRASE with inner volume selection provides high isotropic resolution over extended volumes, overcoming some of the many technical limitations of conventional 2D SE-EPI, whereby making layer specific investigations feasible. Further, the demonstration of columnar level specificity with 3D GRASE, despite contributions from both stimulated echoes and conventional T2 contrast, has made it an attractive alternative over 2D SE-EPI. Here, we assess the spatial specificity of cortical depth dependent 3D GRASE functional responses in human V1 and hMT by comparing it to GE responses. In doing so we demonstrate that 3D GRASE is less sensitive to contributions from large veins in superficial layers, while showing increased specificity (functional tuning) throughout the cortex compared to GE

    Music Alters Visual Perception

    Get PDF
    Background: Visual perception is not a passive process: in order to efficiently process visual input, the brain actively uses previous knowledge (e.g., memory) and expectations about what the world should look like. However, perception is not only influenced by previous knowledge. Especially the perception of emotional stimuli is influenced by the emotional state of the observer. In other words, how we perceive the world does not only depend on what we know of the world, but also by how we feel. In this study, we further investigated the relation between mood and perception. Methods and Findings: We let observers do a difficult stimulus detection task, in which they had to detect schematic happy and sad faces embedded in noise. Mood was manipulated by means of music. We found that observers were more accurate in detecting faces congruent with their mood, corroborating earlier research. However, in trials in which no actual face was presented, observers made a significant number of false alarms. The content of these false alarms, or illusory percepts, was strongly influenced by the observers ’ mood. Conclusions: As illusory percepts are believed to reflect the content of internal representations that are employed by the brain during top-down processing of visual input, we conclude that top-down modulation of visual processing is not purely predictive in nature: mood, in this case manipulated by music, may also directly alter the way we perceive the world
    corecore