99 research outputs found

    Ultra-thin fluorocarbon foils optimise multiscale imaging of three-dimensional native and optically cleared specimens

    Get PDF
    In three-dimensional light microscopy, the heterogeneity of the optical density in a specimen ultimately limits the achievable penetration depth and hence the three-dimensional resolution. The most direct approach to reduce aberrations, improve the contrast and achieve an optimal resolution is to minimise the impact of changes of the refractive index along an optical path. Many implementations of light sheet fluorescence microscopy operate with a large chamber filled with an aqueous immersion medium and a further inner container with the specimen embedded in a possibly entirely different non-aqueous medium. In order to minimise the impact of the latter on the optical quality of the images, we use multi-facetted cuvettes fabricated from vacuum-formed ultra-thin fluorocarbon (FEP) foils. The ultra-thin FEP-foil cuvettes have a wall thickness of about 10–12 µm. They are impermeable to liquids, but not to gases, inert, durable, mechanically stable and flexible. Importantly, the usually fragile specimen can remain in the same cuvette from seeding to fixation, clearing and observation, without the need to remove or remount it during any of these steps. We confirm the improved imaging performance of ultra-thin FEP-foil cuvettes with excellent quality images of whole organs such us mouse oocytes, of thick tissue sections from mouse brain and kidney as well as of dense pancreas and liver organoid clusters. Our ultra-thin FEP-foil cuvettes outperform many other sample-mounting techniques in terms of a full separation of the specimen from the immersion medium, compatibility with aqueous and organic clearing media, quick specimen mounting without hydrogel embedding and their applicability for multiple-view imaging and automated image segmentation. Addit

    Ultra-thin fluorocarbon foils optimise multiscale imaging of three-dimensional native and optically cleared specimens

    Get PDF
    In three-dimensional light microscopy, the heterogeneity of the optical density in a specimen ultimately limits the achievable penetration depth and hence the three-dimensional resolution. The most direct approach to reduce aberrations, improve the contrast and achieve an optimal resolution is to minimise the impact of changes of the refractive index along an optical path. Many implementations of light sheet fluorescence microscopy operate with a large chamber filled with an aqueous immersion medium and a further inner container with the specimen embedded in a possibly entirely different non-aqueous medium. In order to minimise the impact of the latter on the optical quality of the images, we use multi-facetted cuvettes fabricated from vacuum-formed ultra-thin fluorocarbon (FEP) foils. The ultra-thin FEP-foil cuvettes have a wall thickness of about 10–12 µm. They are impermeable to liquids, but not to gases, inert, durable, mechanically stable and flexible. Importantly, the usually fragile specimen can remain in the same cuvette from seeding to fixation, clearing and observation, without the need to remove or remount it during any of these steps. We confirm the improved imaging performance of ultra-thin FEP-foil cuvettes with excellent quality images of whole organs such us mouse oocytes, of thick tissue sections from mouse brain and kidney as well as of dense pancreas and liver organoid clusters. Our ultra-thin FEP-foil cuvettes outperform many other sample-mounting techniques in terms of a full separation of the specimen from the immersion medium, compatibility with aqueous and organic clearing media, quick specimen mounting without hydrogel embedding and their applicability for multiple-view imaging and automated image segmentation. Addit

    A large scale hearing loss screen reveals an extensive unexplored genetic landscape for auditory dysfunction

    Get PDF
    The developmental and physiological complexity of the auditory system is likely reflected in the underlying set of genes involved in auditory function. In humans, over 150 non-syndromic loci have been identified, and there are more than 400 human genetic syndromes with a hearing loss component. Over 100 non-syndromic hearing loss genes have been identified in mouse and human, but we remain ignorant of the full extent of the genetic landscape involved in auditory dysfunction. As part of the International Mouse Phenotyping Consortium, we undertook a hearing loss screen in a cohort of 3006 mouse knockout strains. In total, we identify 67 candidate hearing loss genes. We detect known hearing loss genes, but the vast majority, 52, of the candidate genes were novel. Our analysis reveals a large and unexplored genetic landscape involved with auditory function

    Accelerating cryoprotectant diffusion kinetics improves cryopreservation of pancreatic islets

    Get PDF
    Funder: W. D. Armstrong Fund (School of Technology, University of Cambridge)Abstract: Cryopreservation offers the potential to increase the availability of pancreatic islets for treatment of diabetic patients. However, current protocols, which use dimethyl sulfoxide (DMSO), lead to poor cryosurvival of islets. We demonstrate that equilibration of mouse islets with small molecules in aqueous solutions can be accelerated from > 24 to 6 h by increasing incubation temperature to 37 °C. We utilize this finding to demonstrate that current viability staining protocols are inaccurate and to develop a novel cryopreservation method combining DMSO with trehalose pre-incubation to achieve improved cryosurvival. This protocol resulted in improved ATP/ADP ratios and peptide secretion from β-cells, preserved cAMP response, and a gene expression profile consistent with improved cryoprotection. Our findings have potential to increase the availability of islets for transplantation and to inform the design of cryopreservation protocols for other multicellular aggregates, including organoids and bioengineered tissues

    Entwicklung eines quantitativen Tests auf "endogene Herzglykoside" im Serum. Nachweis erhoehter Konzentrationen und deren Korrelation mit dem Blutdruck bei Patienten mit essentieller Hypertonie

    No full text
    SIGLEAvailable from: Zentralstelle fuer Agrardokumentation und -information (ZADI), Villichgasse 17, D-53177 Bonn / FIZ - Fachinformationszzentrum Karlsruhe / TIB - Technische InformationsbibliothekDEGerman

    High throughput phenotyping of left and right ventricular cardiomyopathy in calcineurin transgene mice.

    No full text
    Consistent protocols for the assessment of diastolic and systolic cardiac function to assure the comparability of existing data on preclinical models are missing. Calcineurin transgene (CN) mice are a preclinical model for hypertrophic and failing hearts. We aimed at evaluating left and right ventricular structural and functional remodeling in CN hearts with an optimized phenotyping protocol. We developed a protocol using techniques and indices comparable to those from human diagnostics for comprehensive in vivo cardiac screening using high-frequency echocardiography, Doppler, electrocardiography and cardiac magnetic resonance (CMR) techniques. We measured left and right ventricular dimensions and function, pulmonary and mitral flow pattern and the hearts electrophysiology non-invasively in <1 h per mouse. We found severe biventricular dilation and a drastic decline in performance in accordance with a condition of heart failure (HF), diastolic dysfunction and defects in electrical conduction in 8-week-old calcineurin transgenic mice. Echocardiography of the left ventricle was performed with and without anesthesia. In all cases absolute values on echocardiography compared with CMR were smaller for LV dimension and wall thickness, resulting in higher fractional shorting and ejection fraction. The study protocol described here opens opportunities to assess the added value of combined echocardiography, Doppler, CMR and ECG recording techniques for the diagnosis of biventricular cardiac pathologies i.e. of HF and to study symptom occurrence and disease progression non-invasively in high-throughput. Phenotyping CN hearts revealed new symptom occurrence and allowed insights into the diverse phenotype of hypertrophic failing hearts
    • …
    corecore