80 research outputs found
Ultra-stable implanted 83Rb/83mKr electron sources for the energy scale monitoring in the KATRIN experiment
The KATRIN experiment aims at the direct model-independent determination of
the average electron neutrino mass via the measurement of the endpoint region
of the tritium beta decay spectrum. The electron spectrometer of the MAC-E
filter type is used, requiring very high stability of the electric filtering
potential. This work proves the feasibility of implanted 83Rb/83mKr calibration
electron sources which will be utilised in the additional monitor spectrometer
sharing the high voltage with the main spectrometer of KATRIN. The source
employs conversion electrons of 83mKr which is continuously generated by 83Rb.
The K-32 conversion line (kinetic energy of 17.8 keV, natural line width of 2.7
eV) is shown to fulfill the KATRIN requirement of the relative energy stability
of +/-1.6 ppm/month. The sources will serve as a standard tool for continuous
monitoring of KATRIN's energy scale stability with sub-ppm precision. They may
also be used in other applications where the precise conversion lines can be
separated from the low energy spectrum caused by the electron inelastic
scattering in the substrate.Comment: 30 pages, 10 figures, 1 table, minor revision of the preprint,
accepted by JINST on 5.2.201
Surface diffusion of Au on Si(111): A microscopic study
The direct evolution of submonolayer two-dimensional Au phases on the Si(111)-(7x7) surface was studied in real time using the spectroscopic photoemission and low energy electron microscope located at the synchrotron radiation source ELETTRA. A finite area covered by 1 monolayer (ML) of gold with a steplike transition zone was prepared by evaporation in situ. Subsequent annealing resulted in the spread of the Au layer and the formation of laterally extended Si(111)-(5x1)-Au and Si(111)-(â3x â3)R30°-Au surface reconstructions. At a temperature around 970 K, the boundary of the gold-covered region propagates on the clean Si(111)-(7x7) and exhibits a nonlinear dependence on time. The ordered Si(111)-(5x1)-Au plateau develops a separated front moving with constant velocity. Two values of the Au diffusion coefficients were estimated at a temperature of about 985 K: (1) D7x7=5,2x10-8 cm2 s-1 as the average diffusion coefficient for Au on a clean Si(111)-(7x7) surface in the concentration range from 0.4 ML up to 0.66 ML and (2) D5x1=1.2x10-7 cm2 s-1 as the lower limit for the diffusion of single Au atoms on the Si(111)-(5x1)-Au ordered phase
Characterization of silicon drift detectors with electrons for the TRISTAN project
Sterile neutrinos are a minimal extension of the standard model of particle physics. A promising model-independent way to search for sterile neutrinos is via high-precision ÎČ-spectroscopy. The Karlsruhe tritium neutrino (KATRIN) experiment, equipped with a novel multi-pixel silicon drift detector focal plane array and read-out system, named the TRISTAN detector, has the potential to supersede the sensitivity of previous laboratory-based searches. In this work we present the characterization of the first silicon drift detector prototypes with electrons and we investigate the impact of uncertainties of the detector\u27s response to electrons on the final sterile neutrino sensitivity
Characterization of Silicon Drift Detectors with Electrons for the TRISTAN Project
Sterile neutrinos are a minimal extension of the Standard Model of Particle
Physics. A promising model-independent way to search for sterile neutrinos is
via high-precision beta spectroscopy. The Karlsruhe Tritium Neutrino (KATRIN)
experiment, equipped with a novel multi-pixel silicon drift detector focal
plane array and read-out system, named the TRISTAN detector, has the potential
to supersede the sensitivity of previous laboratory-based searches. In this
work we present the characterization of the first silicon drift detector
prototypes with electrons and we investigate the impact of uncertainties of the
detector's response to electrons on the final sterile neutrino sensitivity.Comment: 18 pages, 8 figures. J. Phys. G: Nucl. Part. Phys. 48 01500
Analysis methods for the first KATRIN neutrino-mass measurement
We report on the dataset, data handling, and detailed analysis techniques of the first neutrino-mass measurement by the Karlsruhe Tritium Neutrino (KATRIN) experiment, which probes the absolute neutrino-mass scale via the ÎČ-decay kinematics of molecular tritium. The source is highly pure, cryogenic T2 gas. The ÎČ electrons are guided along magnetic field lines toward a high-resolution, integrating spectrometer for energy analysis. A silicon detector counts ÎČ electrons above the energy threshold of the spectrometer, so that a scan of the thresholds produces a precise measurement of the high-energy spectral tail. After detailed theoretical studies, simulations, and commissioning measurements, extending from the molecular final-state distribution to inelastic scattering in the source to subtleties of the electromagnetic fields, our independent, blind analyses allow us to set an upper limit of 1.1 eV on the neutrino-mass scale at a 90% confidence level. This first result, based on a few weeks of running at a reduced source intensity and dominated by statistical uncertainty, improves on prior limits by nearly a factor of two. This result establishes an analysis framework for future KATRIN measurements, and provides important input to both particle theory and cosmology
Quantitative Long-Term Monitoring of the Circulating Gases in the KATRIN Experiment Using Raman Spectroscopy
The Karlsruhe Tritium Neutrino (KATRIN) experiment aims at measuring the effective electron neutrino mass with a sensitivity of 0.2 eV/c, i.e., improving on previous measurements by an order of magnitude. Neutrino mass data taking with KATRIN commenced in early 2019, and after only a few weeks of data recording, analysis of these data showed the success of KATRIN, improving on the known neutrino mass limit by a factor of about two. This success very much could be ascribed to the fact that most of the system components met, or even surpassed, the required specifications during long-term operation. Here, we report on the performance of the laser Raman (LARA) monitoring system which provides continuous high-precision information on the gas composition injected into the experimentâs windowless gaseous tritium source (WGTS), specifically on its isotopic purity of tritiumâone of the key parameters required in the derivation of the electron neutrino mass. The concentrations c for all six hydrogen isotopologues were monitored simultaneously, with a measurement precision for individual components of the order 10 or better throughout the complete KATRIN data taking campaigns to date. From these, the tritium purity, ΔT, is derived with precision of <10 and trueness of <3 Ă 10, being within and surpassing the actual requirements for KATRIN, respectively
Precision measurement of the electron energy-loss function in tritium and deuterium gas for the KATRIN experiment
The KATRIN experiment is designed for a direct and model-independent
determination of the effective electron anti-neutrino mass via a high-precision
measurement of the tritium -decay endpoint region with a sensitivity on
of 0.2eV/c (90% CL). For this purpose, the -electrons
from a high-luminosity windowless gaseous tritium source traversing an
electrostatic retarding spectrometer are counted to obtain an integral spectrum
around the endpoint energy of 18.6keV. A dominant systematic effect of the
response of the experimental setup is the energy loss of -electrons from
elastic and inelastic scattering off tritium molecules within the source. We
determined the \linebreak energy-loss function in-situ with a pulsed
angular-selective and monoenergetic photoelectron source at various
tritium-source densities. The data was recorded in integral and differential
modes; the latter was achieved by using a novel time-of-flight technique.
We developed a semi-empirical parametrization for the energy-loss function
for the scattering of 18.6-keV electrons from hydrogen isotopologs. This model
was fit to measurement data with a 95% T gas mixture at 30K, as used in
the first KATRIN neutrino mass analyses, as well as a D gas mixture of 96%
purity used in KATRIN commissioning runs. The achieved precision on the
energy-loss function has abated the corresponding uncertainty of
[arXiv:2101.05253] in the KATRIN
neutrino-mass measurement to a subdominant level.Comment: 12 figures, 18 pages; to be submitted to EPJ
Improved eV-scale sterile-neutrino constraints from the second KATRIN measurement campaign
We present the results of the light sterile neutrino search from the second Karlsruhe Tritium Neutrino (KATRIN) measurement campaign in 2019. Approaching nominal activity, 3.76Ă106 tritium ÎČ-electrons are analyzed in an energy window extending down to 40 eV below the tritium end point at E0=18.57ââkeV. We consider the 3Îœ+1 framework with three active and one sterile neutrino flavors. The analysis is sensitive to a fourth mass eigenstate m24âČ1600ââeV2 and active-to-sterile mixing |Ue4|2âł6Ă10â3. As no sterile-neutrino signal was observed, we provide improved exclusion contours on m24 and |Ue4|2 at 95% C.L. Our results supersede the limits from the Mainz and Troitsk experiments. Furthermore, we are able to exclude the large Îm241 solutions of the reactor antineutrino and gallium anomalies to a great extent. The latter has recently been reaffirmed by the BEST Collaboration and could be explained by a sterile neutrino with large mixing. While the remaining solutions at small Îm241 are mostly excluded by short-baseline reactor experiments, KATRIN is the only ongoing laboratory experiment to be sensitive to relevant solutions at large Îm241 through a robust spectral shape analysis
- âŠ