18 research outputs found

    Cryopreserved homograft valves in the pulmonary position: Risk analysis for intermediate-term failure

    Get PDF
    AbstractObjective: The purpose of this study was to examine the durability of cryopreserved homografts used to replace the “pulmonary” valve and to identify factors associated with their late deterioration. Methods: We reviewed our entire experience (1985-1997) with 331 survivors in whom cryopreserved homograft valves (pulmonary, n = 304; aortic, n = 27) were used to reconstruct the pulmonary outflow tract. Median age was 14 years (range, 2 days–62 years). Operations included Ross operation (n = 259), tetralogy of Fallot (n = 41), truncus arteriosus (n = 14), Rastelli operation (n = 11), and others (n = 6). Median follow-up was 3.8 years (range, 0.2–11.2 years); late echographic follow-up was complete for 97% of patients. Homograft failure was defined as the need for explantation and valve-related death; homograft dysfunction was defined as a pulmonary insufficiency grade 3/4 or greater and a transvalvular gradient of 40 mm Hg or greater. Results: Homograft failure occurred in 9% (30 of 331 patients; Kaplan-Meier); freedom from failure was 82% ± 4% at 8 years. Homograft dysfunction occurred in 12% (39 of 331 patients), although freedom from dysfunction was 76% ± 4% at 8 years. For aortic homografts, this was 56% ± 11%, compared to 80% ± 4% for pulmonary homografts (P = .003). For patients aged less than 3 years (n = 38), this was 51% ± 12%, compared with 87% ± 4% for older patients (P = .0001). By multivariable analysis, younger age of homograft donors, non-Ross operation, and later year of operation were associated with homograft failure; younger age of homograft donors, later year of operation, and use of an aortic homograft were associated with homograft dysfunction. Conclusions: Homograft valves function satisfactorily in the pulmonary position at mid-term follow-up. The pulmonary homograft valve appears to be more durable than the aortic homograft valve in the pulmonary position. (J Thorac Cardiovasc Surg 1999;117:141-7

    Comparative evaluation of left ventricular mass regression after aortic valve replacement: a prospective randomized analysis

    Get PDF
    Background: We assessed the hemodynamic performance of various prostheses and the clinical outcomes after aortic valve replacement, in different age groups. Methods: One-hundred-and-twenty patients with isolated aortic valve stenosis were included in this prospective randomized randomised trial and allocated in three age-groups to receive either pulmonary autograft (PA, n = 20) or mechanical prosthesis (MP, Edwards Mira n = 20) in group 1 (age 75). Clinical outcomes and hemodynamic performance were evaluated at discharge, six months and one year. Results: In group 1, patients with PA had significantly lower mean gradients than the MP (2.6 vs. 10.9 mmHg, p = 0.0005) with comparable left ventricular mass regression (LVMR). Morbidity included 1 stroke in the PA population and 1 gastrointestinal bleeding in the MP subgroup. In group 2, mean gradients did not differ significantly between both populations (7.0 vs. 8.9 mmHg, p = 0.81). The rate of LVMR and EF were comparable at 12 months; each group with one mortality. Morbidity included 1 stroke and 1 gastrointestinal bleeding in the stentless and 3 bleeding complications in the MP group. In group 3, mean gradients did not differ significantly (7.8 vs 6.5 mmHg, p = 0.06). Postoperative EF and LVMR were comparable. There were 3 deaths in the stented group and no mortality in the stentless group. Morbidity included 1 endocarditis and 1 stroke in the stentless compared to 1 endocarditis, 1 stroke and one pulmonary embolism in the stented group. Conclusions: Clinical outcomes justify valve replacement with either valve substitute in the respective age groups. The PA hemodynamically outperformed the MPs. Stentless valves however, did not demonstrate significantly superior hemodynamics or outcomes in comparison to stented bioprosthesis or MPs

    LV reverse remodeling imparted by aortic valve replacement for severe aortic stenosis; is it durable? A cardiovascular MRI study sponsored by the American Heart Association

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>In patients with severe aortic stenosis (AS), long-term data tracking surgically induced effects of afterload reduction on reverse LV remodeling are not available. Echocardiographic data is available short term, but in limited fashion beyond one year. Cardiovascular MRI (CMR) offers the ability to serially track changes in LV metrics with small numbers due to its inherent high spatial resolution and low variability.</p> <p>Hypothesis</p> <p>We hypothesize that changes in LV structure and function following aortic valve replacement (AVR) are detectable by CMR and once triggered by AVR, continue for an extended period.</p> <p>Methods</p> <p>Tweny-four patients of which ten (67 ± 12 years, 6 female) with severe, but compensated AS underwent CMR pre-AVR, 6 months, 1 year and up to 4 years post-AVR. 3D LV mass index, volumetrics, LV geometry, and EF were measured.</p> <p>Results</p> <p>All patients survived AVR and underwent CMR 4 serial CMR's. LVMI markedly decreased by 6 months (157 ± 42 to 134 ± 32 g/m<sup><b>2</b></sup>, p < 0.005) and continued trending downwards through 4 years (127 ± 32 g/m<sup><b>2</b></sup>). Similarly, EF increased pre to post-AVR (55 ± 22 to 65 ± 11%,(p < 0.05)) and continued trending upwards, remaining stable through years 1-4 (66 ± 11 vs. 65 ± 9%). LVEDVI, initially high pre-AVR, decreased post-AVR (83 ± 30 to 68 ± 11 ml/m2, p < 0.05) trending even lower by year 4 (66 ± 10 ml/m<sup><b>2</b></sup>). LV stroke volume increased rapidly from pre to post-AVR (40 ± 11 to 44 ± 7 ml, p < 0.05) continuing to increase non-significantly through 4 years (49 ± 14 ml) with these LV metrics paralleling improvements in NYHA. However, LVmass/volume, a 3D measure of LV geometry, remained unchanged over 4 years.</p> <p>Conclusion</p> <p>After initial beneficial effects imparted by AVR in severe AS patients, there are, as expected, marked improvements in LV reverse remodeling. Via CMR, surgically induced benefits to LV structure and function are durable and, unexpectedly express continued, albeit markedly incomplete improvement through 4 years post-AVR concordant with sustained improved clinical status. This supports down-regulation of both mRNA and MMP activity acutely with robust suppression long term.</p

    Disordini dell’efflusso ventricolare sinistro

    No full text
    corecore