2 research outputs found

    Active contour configuration model for estimating the posterior ablative margin in image fusion of real-time ultrasound and 3D ultrasound or magnetic resonance images for radiofrequency ablation: an experimental study

    Get PDF
    Purpose The purpose of this study was to evaluate the accuracy of an active contour model for estimating the posterior ablative margin in images obtained by the fusion of real-time ultrasonography (US) and 3-dimensional (3D) US or magnetic resonance (MR) images of an experimental tumor model for radiofrequency ablation. Methods Chickpeas (n=12) and bovine rump meat (n=12) were used as an experimental tumor model. Grayscale 3D US and T1-weighted MR images were pre-acquired for use as reference datasets. US and MR/3D US fusion was performed for one group (n=4), and US and 3D US fusion only (n=8) was performed for the other group. Half of the models in each group were completely ablated, while the other half were incompletely ablated. Hyperechoic ablation areas were extracted using an active contour model from real-time US images, and the posterior margin of the ablation zone was estimated from the anterior margin. After the experiments, the ablated pieces of bovine rump meat were cut along the electrode path and the cut planes were photographed. The US images with the estimated posterior margin were compared with the photographs and post-ablation MR images. The extracted contours of the ablation zones from 12 US fusion videos and post-ablation MR images were also matched. Results In the four models fused under real-time US with MR/3D US, compression from the transducer and the insertion of an electrode resulted in misregistration between the real-time US and MR images, making the estimation of the ablation zones less accurate than was achieved through fusion between real-time US and 3D US. Eight of the 12 post-ablation 3D US images were graded as good when compared with the sectioned specimens, and 10 of the 12 were graded as good in a comparison with nicotinamide adenine dinucleotide staining and histopathologic results. Conclusion Estimating the posterior ablative margin using an active contour model is a feasible way of predicting the ablation area, and US/3D US fusion was more accurate than US/MR fusion

    Investigation of the Changes in Electronic Properties of Nickel Oxide (NiO<sub><i>x</i></sub>) Due to UV/Ozone Treatment

    No full text
    Drastic reduction in nickel oxide (NiO<sub><i>x</i></sub>) film resistivity and ionization potential is observed when subjected to ultraviolet (UV)/ozone (O<sub>3</sub>) treatment. X-ray photoemission spectroscopy suggests that UV/O<sub>3</sub> treatment changes the film stoichiometry by introducing Ni vacancy defects. Oxygen-rich NiO<sub><i>x</i></sub> having Ni vacancy defects behaves as a p-type semiconductor. Therefore, in this work, a simple and effective technique to introduce doping in NiO<sub><i>x</i></sub> is shown. Angle-resolved XPS reveals that the effect of UV/O<sub>3</sub> treatment does not only alter the film surface property but also introduces oxygen-rich stoichiometry throughout the depth of the film. Finally, simple metal/interlayer/semiconductor (MIS) contacts are fabricated on p-type Si using NiO<sub><i>x</i></sub> as the interlayer and different metals. Significant barrier height reduction is observed with respect to the control sample following UV/O<sub>3</sub> treatment, which is in agreement with the observed reduction in film resistivity. From an energy band diagram point of view, the introduction of the UV/O<sub>3</sub> treatment changes the defect state distribution, resulting in a change in the pinning of the Fermi level. Therefore, this work also shows that the Fermi level pinning property of NiO<sub><i>x</i></sub> can be controlled using UV/O<sub>3</sub> treatment
    corecore