19 research outputs found

    Clinical Performance of a Salivary Amylase Activity Monitor During Hemodialysis Treatment

    Get PDF
    The hemodialysis procedure is thought to be a physical stressor in the majority of hemodialyzed patients. Previous studies suggest that elevated salivary amylase level may correlate with increased plasma norepinephrine level under psychological and physical stress conditions. In this study, we investigated biological stress reactivity during hemodialysis treatment using salivary amylase activity as a biomarker. Seven patients (male/female = 5/2, age: 67.7+/−5.9 years) who had been receiving regular 4 h hemodialysis were recruited. Salivary amylase activity was measured using a portable analyzer every hour during the hemodialysis session. Salivary amylase activity was shown to be relatively stable and constant throughout hemodialysis, whereas there were significant changes in systolic blood pressure and pulse rate associated with blood volume reduction. Our results show that hemodialysis treatment per se dose not affect salivary amylase activity

    Das Allegorische beim frühen Hofmannsthal

    No full text

    Shujinko wa naze korosareta ka : Hofumansutaru "Kihei no monogatari" no nazo

    Get PDF

    Esophageal Endoscopic Submucosal Dissection Assisted by an Overtube with a Traction Forceps: An Animal Study

    Get PDF
    Esophageal endoscopic submucosal dissection (ESD) is technically difficult. To make it safer, we developed a novel method using overtube with a traction forceps (OTF) for countertraction during submucosal dissection. We conducted an ex vivo animal study and compared the clinical outcomes between OTF-ESD and conventional method (C-ESD). A total of 32 esophageal ESD procedures were performed by four beginner and expert endoscopists. After circumferential mucosal incision for the target lesion, structured as the isolated pig esophagus 3 cm long, either C-ESD or OTF-ESD was randomly selected for submucosal dissection. All the ESD procedures were completed as en bloc resections, while perforation only occurred in a beginner’s C-ESD procedure. The dissection time for OTF-ESD was significantly shorter than that for C-ESD for both the beginner and expert endoscopists (22.8±8.3 min versus 7.8±4.5 min, P<0.001, and 11.3±4.4 min versus 5.9±2.5 min, P=0.01, resp.). The frequency and volume of the submucosal injections were significantly smaller for OTF-ESD than for C-ESD (1.3±0.6 times versus 2.9±1.5 times, P<0.001, and 5.3±2.8 mL versus 15.6±7.3 mL, P<0.001, resp.). Histologically, muscular injury was more common among the C-ESD procedures (80% versus 13%, P=0.009). Our results indicated that the OTF-ESD technique is useful for the safe and easy completion of esophageal ESD
    corecore