3,115 research outputs found
Cardiac Angiosarcoma on the Right Atrium: Two Cases
We detected two cases of right atrial angiosarcoma that had a similar appearance on imaging studies. Although the surgical findings were similar for the two patients, one had a clear resection margin, while the other had tumor cells in the resection margin on frozen biopsy. We suggest that preoperative data on magnetic resonance imaging and computed tomography in patients with angiosarcomas may not predict the exact extent of surgical resection or prognostic outcomes
Spin cast ferroelectric beta poly(vinylidene fluoride) thin films via rapid thermal annealing
We describe a method of fabricating ferroelectric beta-type poly(vinylidene fluoride) (PVDF) thin films on Au substrate by the humidity controlled spin casting combined with rapid thermal treatment. Our method produces thin uniform ferroelectric PVDF film with ordered beta crystals consisting of characteristic needlelike microdomains. A capacitor with a 160 nm thick ferroelectric PVDF film exhibits the remanent polarization and coercive voltage of similar to 7.0 mu C/cm(2) and 8 V, respectively, with the temperature stability of up to 160 degrees C. A ferroelectric field effect transistor also shows a drain current bistablility of 100 at zero gate voltage with +/- 20 V gate voltage sweep. (C) 2008 American Institute of Physicsopen485
The Megalocytivirus RBIV Induces Apoptosis and MHC Class I Presentation in Rock Bream (Oplegnathus fasciatus) Red Blood Cells
The Megalocytivirus RBIV Induces
Apoptosis and MHC Class I
Presentation in Rock Bream
(Oplegnathus fasciatus) Red Blood
CellsThis research was supported by the European Research Council
(ERC Starting Grant GA639249)and by the Basic Science
Research Program through the National Research Foundation of
Korea (NRF) funded by the Ministry of Science, ICT & Future
Planning (2015R1C1A1A01053685The proteomic analysis was performed
in the Proteomics Facility of The Spanish National Center
for Biotechnology (CNB-CSIC) that belongs to ProteoRed,
PRB3-ISCIII, supported by grant PT17/001
Magnon-induced non-Markovian friction of a domain wall in a ferromagnet
Motivated by the recent study on the quasiparticle-induced friction of
solitons in superfluids, we theoretically study magnon-induced intrinsic
friction of a domain wall in a one-dimensional ferromagnet. To this end, we
start by obtaining the hitherto overlooked dissipative interaction of a domain
wall and its quantum magnon bath to linear order in the domain-wall velocity
and to quadratic order in magnon fields. An exact expression for the pertinent
scattering matrix is obtained with the aid of supersymmetric quantum mechanics.
We then derive the magnon-induced frictional force on a domain wall in two
different frameworks: time-dependent perturbation theory in quantum mechanics
and the Keldysh formalism, which yield identical results. The latter, in
particular, allows us to verify the fluctuation-dissipation theorem explicitly
by providing both the frictional force and the correlator of the associated
stochastic Langevin force. The potential for magnons induced by a domain wall
is reflectionless, and thus the resultant frictional force is non-Markovian
similarly to the case of solitons in superfluids. They share an intriguing
connection to the Abraham-Lorentz force that is well-known for its causality
paradox. The dynamical responses of a domain wall are studied under a few
simple circumstances, where the non-Markovian nature of the frictional force
can be probed experimentally. Our work, in conjunction with the previous study
on solitons in superfluids, shows that the macroscopic frictional force on
solitons can serve as an effective probe of the microscopic degrees of freedom
of the system.Comment: 13 pages, 2 figure
Autonomous Control Strategy of DC Microgrid for Islanding mode using Power Line Communication
This paper proposes a DC-bus signaling (DBS) method for autonomous power management in a DC microgrid, used to improve its reliability. Centralized power management systems require communication between the power sources and loads. However, the DBS method operates based on the common DC-bus voltage and does not require communication. Based on the DC-bus voltage band, the DC-bus voltage can be used to inform the status of the DC-bus in various scenarios. The DC microgrid operates independently to maintain the system stably in the DC-bus voltage band. The DC microgrid can be divided into a grid-connected mode and an islanding mode. This paper proposes a control strategy based on power management of various independent components in islanding mode. In addition, the autonomous control method for switching the converter???s operation between grid-connected mode and islanding mode is proposed. A DC microgrid test bed consisting of a grid-connected AC/DC converter, a bidirectional DC/DC converter, a renewable energy simulator, DC home appliances and a DC-bus protector is used to test the proposed control strategy. The proposed autonomous control strategy is experimentally verified using the DC microgrid test bed
- …