    Mechanical Circulatory Support Devices for the Treatment of Cardiogenic Shock Complicating Acute Myocardial Infarction—A Review

    No full text
    Cardiogenic shock complicating acute myocardial infarction is a complex clinical condition associated with dismal prognosis. Routine early target vessel revascularization remains the most effective treatment to substantially improve outcomes, but mortality remains high. Temporary circulatory support devices have emerged with the aim to enhance cardiac unloading and improve end-organ perfusion. However, quality evidence to guide device selection, optimal installation timing, and post-implantation management are scarce, stressing the importance of multidisciplinary expert care. This review focuses on the contemporary use of short-term support devices in the setting of cardiogenic shock following acute myocardial infarction, including the common challenges associated this practice

    Immature Platelet Fraction and Clinical Outcomes in Patients Undergoing Transcatheter Aortic Valve Implantation

    No full text
    Introduction Immature platelets or reticulated platelets are newly released thrombocytes. They can be identified by their large size and high RNA cytoplasm concentration. Immature platelet fraction (IPF) represents the percentage of immature circulative platelets relative to the total number of platelets. The role of IPF in patients undergoing transcatheter aortic valve implantation (TAVI) is unknown. The aim of the current trial was to assess the levels of IPF in patients undergoing TAVI and correlation with clinical outcomes. Material and Methods Immature platelet fraction levels were measured 3 times in all patients (preprocedure, 1-2 days post-procedure and 1-month post-procedure). Immature platelet fraction measurement was carried out using an autoanalyzer (Sysmex XE-2100). Patients were followed for 12 months. Primary outcomes were defined as complications during hospitalizations, rehospitalization, and mortality. Results Fifty-one patients were included in the study. Mean age was 79.8 (±9.6), and 28 (55%) were women. Twenty-one patients (41%) had complications: Of them, 6 of 21 (29%) occurred during hospitalizations (2—vascular complications; 2—sepsis, 2—implantation of a pacemaker), 9 of 21 (43%) patients were rehospitalized after the index admission, and 6 patients died during the follow-up period. Multivariate Cox regression analysis found that IPF 7% in patients undergoing TAVI is associated with worse outcomes. Further studies are needed to better understand this phenomenon

    First-in-human dedicated leaflet splitting device for prevention of coronary obstruction in transcatheter aortic valve replacement

    No full text
    BackgroundCoronary artery obstruction is a life-threatening complication of transcatheter aortic valve replacement (TAVR) procedures. Current preventive strategies are suboptimal.ObjectivesThe aim of this study was to describe bench testing and clinical experience with a novel device that splits valve leaflets that are at risk for causing coronary obstruction after TAVR, allowing normal coronary flow.MethodsThe ShortCut device was initially tested in vitro and preclinically in a porcine model for functionality and safety. The device was subsequently offered to patients at elevated risk for coronary obstruction. Risk for coronary obstruction was based on computed tomography–based anatomical characteristics. Procedure success was determined as patient survival at 30 days with a functioning new valve, without stroke or coronary obstruction.ResultsFollowing a successful completion of bench testing and preclinical trial, the device was used in 8 patients with failed bioprosthetic valves (median age 81 years; IQR: 72-85 years; 37.5% man) at 2 medical centers. A total of 11 leaflets were split: 5 patients (63.5%) were considered at risk for left main obstruction alone, and 3 patients (37.5%) were at risk for double coronary obstruction. All patients underwent successful TAVR without evidence of coronary obstruction. All patients were discharged from the hospital in good clinical condition, and no adverse neurologic events were noted. Procedure success was 100%.ConclusionsEvaluation of the first dedicated transcatheter leaflet-splitting device shows that the device can successfully split degenerated bioprosthetic valve leaflets. The procedure was safe and successfully prevented coronary obstruction in patients at risk for this complication following TAVR.<br/