27 research outputs found
Automated discrete electron tomography – Towards routine high-fidelity reconstruction of nanomaterials
Electron tomography is an essential imaging technique for the investigation of morphology and 3D structure of nanomaterials. This method, however, suffers from well-known missing wedge artifacts due to a restricted tilt range, which limits the objectiveness, repeatability and efficiency of quantitative structural analysis. Discrete tomography represents one of the promising reconstruction techniques for materials science, potentially capable of delivering higher fidelity reconstructions by exploiting the prior knowledge of the limited number of material compositions in a specimen. However, the application of discrete tomography to practical datasets remains a difficult task due to the underlying challenging mathematical problem. In practice, it is often hard to obtain consistent reconstructions from experimental datasets. In addition, numerous parameters need to be tuned manually, which can lead to bias and non-repeatability. In this paper, we present the application of a new iterative reconstruction technique, named TVR-DART, for discrete electron tomography. The technique is capable of consistently delivering reconstructions with significantly reduced missing wedge artifacts for a variety of challenging data and imaging conditions, and can automatically estimate its key parameters. We describe the principles of the technique and apply it to datasets from three different types of samples acquired under diverse imaging modes. By further reducing the available tilt range and number of projections, we show that the proposed technique can still produce consistent reconstructions with minimized missing wedge artifacts. This new development promises to provide the electron microscopy community with an easy-to-use and robust tool for high-fidelity 3D characterization of nanomaterials
Review of influenza-associated pulmonary aspergillosis in ICU patients and proposal for a case definition: an expert opinion
Purpose: Invasive pulmonary aspergillosis is increasingly reported in patients with influenza admitted to the intensive care unit (ICU). Classification of patients with influenza-associated pulmonary aspergillosis (IAPA) using the current definitions for invasive fungal diseases has proven difficult, and our aim was to develop case definitions for IAPA that can facilitate clinical studies. Methods: A group of 29 international experts reviewed current insights into the epidemiology, diagnosis and management of IAPA and proposed a case definition of IAPA through a process of informal consensus. Results: Since IAPA may develop in a wide range of hosts, an entry criterion was proposed and not host factors. The entry criterion was defined as a patient requiring ICU admission for respiratory distress with a positive influenza test temporally related to ICU admission. In addition, proven IAPA required histological evidence of invasive septate hyphae and mycological evidence for Aspergillus. Probable IAPA required the detection of galactomannan or positive Aspergillus culture in bronchoalveolar lavage (BAL) or serum with pulmonary infiltrates or a positive culture in upper respiratory samples with bronchoscopic evidence for tracheobronchitis or cavitating pulmonary infiltrates of recent onset. The IAPA case definitions may be useful to classify patients with COVID-19-associated pulmonary aspergillosis (CAPA), while awaiting further studies that provide more insight into the interaction between Aspergillus and the SARS-CoV-2-infected lung. Conclusion: A consensus case definition of IAPA is proposed, which will facilitate research into the epidemiology, diagnosis and management of this emerging acute and severe Aspergillus disease, and may be of use to study CAPA
Factors Associated with Revision Surgery after Internal Fixation of Hip Fractures
Background: Femoral neck fractures are associated with high rates of revision surgery after management with internal fixation. Using data from the Fixation using Alternative Implants for the Treatment of Hip fractures (FAITH) trial evaluating methods of internal fixation in patients with femoral neck fractures, we investigated associations between baseline and surgical factors and the need for revision surgery to promote healing, relieve pain, treat infection or improve function over 24 months postsurgery. Additionally, we investigated factors associated with (1) hardware removal and (2) implant exchange from cancellous screws (CS) or sliding hip screw (SHS) to total hip arthroplasty, hemiarthroplasty, or another internal fixation device. Methods: We identified 15 potential factors a priori that may be associated with revision surgery, 7 with hardware removal, and 14 with implant exchange. We used multivariable Cox proportional hazards analyses in our investigation. Results: Factors associated with increased risk of revision surgery included: female sex, [hazard ratio (HR) 1.79, 95% confidence interval (CI) 1.25-2.50; P = 0.001], higher body mass index (fo
Standing stability evaluation using a triaxial accelerometer
A triaxial accelerometer is placed at the back of the subject at the height of the center of mass. Force plate data are collected simultaneously. Subjects stand in a comfortable position with eyes open, eyes closed and doing cognitive tasks; and with feet together with eyes open and closed. The cognitive tasks are: mathematical, auditory Stroop and memory. The force plate data are processed to obtain the center of pressure and from it the parameters of: mean radius, speed and frequency, and base of support. The same parameters are obtained from the combined accelerations vector projection on the floor, found from the triaxial accelerometer data. The mean angular velocity, angular acceleration and accelerations in the horizontal plane at the level of the accelerometer are calculated T-tests indicate that for most parameters the accelerometer measurements are able to distinguish between the different test conditions as well as the force plate (p⩽0.05
Standing balance evaluation using a triaxial accelerometer
This paper presents a new inherently triaxial accelerometer-based system for determining the ability to maintain balance while standing. In this study, the accelerometer was placed at the back of the subject at the approximate height of the centre of mass. The data were processed to obtain five performance parameters. Paired t-tests indicated that the accelerometer measurements were able to distinguish between the different test conditions as well as or better than simultaneous AMTI™ force platform measurements (P≤0.05). The accelerometer system is fully portable, independent of inclination in space, low-cost and allows long term measurements of standing balance