94 research outputs found

    The problem of obesity : is there a role for antagonists of the renin-angiotensin system?

    Full text link
    Obesity is a major health problem worldwide; it is associated with more than 30 medical conditions and is a leading cause of unnecessary deaths. Adipose tissue not only acts as an energy store, but also behaves like an endocrine organ, synthesising and secreting numerous hormones and cytokines. Angiotensin II (ANG II) is the biologically active component of the renin-angiotensin system (RAS). The RAS is present in adipose tissue and evidence suggests that ANG II is intimately linked to obesity. Indeed, ANG II increases fat cell growth and differentiation, increases synthesis, uptake and storage of fatty acids and triglycerides and possibly inhibits lipolysis. Evidence obtained using genetically modified animals has shown that the amount of body fat is directly related to the amount of ANG II, i.e., animals with low levels of ANG II have reduced fat stores while animals with excessive ANG II have increased fat stores. In humans, epidemiological evidence has shown that body fat is correlated with angiotensinogen, a precursor of ANG II, or other components of the RAS. Furthermore, blocking the production and/or actions of ANG II with drugs or natural substances decreases body fat. The decrease in body fat caused by such treatments predominantly occurs in abdominal fat depots and appears to be independent of energy intake and digestibility. Clearly, ANG II has an important role in the accumulation of body fat and the possibility exists that treatment of obesity will be enhanced by the use of natural or synthetic substances that interfere with ANG II.<br /

    Extended search for the invisible axion with the axion dark matter experiment

    Get PDF
    This Letter reports on a cavity haloscope search for dark matter axions in the Galactic halo in the mass range 2.81–3.31μeV. This search utilizes the combination of a low-noise Josephson parametric amplifier and a large-cavity haloscope to achieve unprecedented sensitivity across this mass range. This search excludes the full range of axion-photon coupling values predicted in benchmark models of the invisible axion that solve the strong CP problem of quantum chromodynamics

    Study of cosmogenic activation above ground for the DarkSide-20k experiment

    Get PDF
    The activation of materials due to exposure to cosmic rays may become an important background source for experiments investigating rare event phenomena. DarkSide-20k, currently under construction at the Laboratori Nazionali del Gran Sasso, is a direct detection experiment for galactic dark matter particles, using a two-phase liquid-argon Time Projection Chamber (TPC) filled with 49.7 tonnes (active mass) of Underground Argon (UAr) depleted in 39Ar. Despite the outstanding capability of discriminating / background in argon TPCs, this background must be considered because of induced dead time or accidental coincidences mimicking dark-matter signals and it is relevant for low-threshold electron-counting measurements. Here, the cosmogenic activity of relevant long-lived radioisotopes induced in the experiment has been estimated to set requirements and procedures during preparation of the experiment and to check that it is not dominant over primordial radioactivity; particular attention has been paid to the activation of the 120 t of UAr used in DarkSide-20k. Expected exposures above ground and production rates, either measured or calculated, have been considered in detail. From the simulated counting rates in the detector due to cosmogenic isotopes, it is concluded that activation in copper and stainless steel is not problematic. The activity of 39Ar induced during extraction, purification and transport on surface is evaluated to be 2.8% of the activity measured in UAr by DarkSide-50 experiment, which used the same underground source, and thus considered acceptable. Other isotopes in the UAr such as 37Ar and 3H are shown not to be relevant due to short half-life and assumed purification methods

    Non-Virialized Axion Search Sensitive to Doppler Effects in the Milky Way Halo

    Full text link
    The Axion Dark Matter eXperiment (ADMX) has previously excluded Dine-Fischler-Srednicki-Zhitnisky (DFSZ) axions between 680-790 MHz under the assumption that the dark matter is described by the isothermal halo model. However, the precise nature of the velocity distribution of dark matter is still unknown, and alternative models have been proposed. We report the results of a non-virialized axion search over the mass range 2.81-3.31 {\mu}eV, corresponding to the frequency range 680-800 MHz. This analysis marks the most sensitive search for non-virialized axions sensitive to Doppler effects in the Milky Way Halo to date. Accounting for frequency shifts due to the detector's motion through the Galaxy, we exclude cold flow relic axions with a velocity dispersion of order 10^-7 c with 95% confidence

    Measurement of isotopic separation of argon with the prototype of the cryogenic distillation plant Aria for dark matter searches

    Get PDF
    The Aria cryogenic distillation plant, located in Sardinia, Italy, is a key component of the DarkSide-20k experimental program for WIMP dark matter searches at the INFN Laboratori Nazionali del Gran Sasso, Italy. Aria is designed to purify the argon, extracted from underground wells in Colorado, USA, and used as the DarkSide-20k target material, to detector-grade quality. In this paper, we report the first measurement of argon isotopic separation by distillation with the 26&nbsp;m tall Aria prototype. We discuss the measurement of the operating parameters of the column and the observation of the simultaneous separation of the three stable argon isotopes: 36Ar , 38Ar , and 40Ar . We also provide a detailed comparison of the experimental results with commercial process simulation software. This measurement of isotopic separation of argon is a significant achievement for the project, building on the success of the initial demonstration of isotopic separation of nitrogen using the same equipment in 2019

    Study on cosmogenic activation above ground for the DarkSide-20k project

    Get PDF
    The activation of materials due to the exposure to cosmic rays may become an important background source for experiments investigating rare event phenomena. DarkSide-20k is a direct detection experiment for galactic dark matter particles, using a two-phase liquid argon time projection chamber filled with 49.7 tonnes (active mass) of Underground Argon (UAr) depleted in 39Ar. Here, the cosmogenic activity of relevant long-lived radioisotopes induced in the argon and other massive components of the set-up has been estimated; production of 120 t of radiopure UAr is foreseen. The expected exposure above ground and production rates, either measured or calculated, have been considered. From the simulated counting rates in the detector due to cosmogenic isotopes, it is concluded that activation in copper and stainless steel is not problematic. Activation of titanium, considered in early designs but not used in the final design, is discussed. The activity of 39Ar induced during extraction, purification and transport on surface, in baseline conditions, is evaluated to be 2.8% of the activity measured in UAr from the same source, and thus considered acceptable. Other products in the UAr such as 37Ar and 3H are shown to not be relevant due to short half-life and assumed purification methods

    Directionality of nuclear recoils in a liquid argon time projection chamber

    Full text link
    The direct search for dark matter in the form of weakly interacting massive particles (WIMP) is performed by detecting nuclear recoils (NR) produced in a target material from the WIMP elastic scattering. A promising experimental strategy for direct dark matter search employs argon dual-phase time projection chambers (TPC). One of the advantages of the TPC is the capability to detect both the scintillation and charge signals produced by NRs. Furthermore, the existence of a drift electric field in the TPC breaks the rotational symmetry: the angle between the drift field and the momentum of the recoiling nucleus can potentially affect the charge recombination probability in liquid argon and then the relative balance between the two signal channels. This fact could make the detector sensitive to the directionality of the WIMP-induced signal, enabling unmistakable annual and daily modulation signatures for future searches aiming for discovery. The Recoil Directionality (ReD) experiment was designed to probe for such directional sensitivity. The TPC of ReD was irradiated with neutrons at the INFN Laboratori Nazionali del Sud, and data were taken with 72 keV NRs of known recoil directions. The direction-dependent liquid argon charge recombination model by Cataudella et al. was adopted and a likelihood statistical analysis was performed, which gave no indications of significant dependence of the detector response to the recoil direction. The aspect ratio R of the initial ionization cloud is estimated to be 1.037 +/- 0.027 and the upper limit is R < 1.072 with 90% confidence levelComment: 20 pages, 10 figures, submitted to Eur. Phys. J.

    Search for invisible axion dark matter with the Axion Dark Matter Experiment

    Get PDF
    This Letter reports the results from a haloscope search for dark matter axions with masses between 2.66 and 2.81ÎĽeV. The search excludes the range of axion-photon couplings predicted by plausible models of the invisible axion. This unprecedented sensitivity is achieved by operating a large-volume haloscope at subkelvin temperatures, thereby reducing thermal noise as well as the excess noise from the ultralow-noise superconducting quantum interference device amplifier used for the signal power readout. Ongoing searches will provide nearly definitive tests of the invisible axion model over a wide range of axion masses

    Spondylarthropathies (including psoriatic arthritis): 244. Validity of Colour Doppler and Spectral Doppler Ultrasound of Sacroilicac Joints Againts Physical Examination as Gold Standard

    Get PDF
    Background: Sacroiliac joints (SJ) involvement is a distinctive and charasteristic feature of Spondyloarthritis (SpA) and x-ray is the test routinely used to make a diagnosis. However, x-ray reveals late structural damage but cannot detect active inflammation. The objective of this study was to assess the validity of Doppler ultrasound in SJ. Methods: Prospective blinded and controlled study of SJ, in which three populations were compared. We studied 106 consecutive cases, who were divided into three groups: a) 53 patients diagnosed with SpA who had inflammatory lumbar and gluteal pain assessed by a rheumatologist; b) 26 patients diagnosed with SpA who didn't have SJ tenderness and had normal physical examination; c) control group of 27 subjects (healthy subjetcs or with mechanical lumbar pain). All patients included that were diagnosed with SpA met almost the European Spondyloarthropathy Study Group (ESSG) classification criteria. Physical examination of the SJ included: sacral sulcus tenderness, iliac gapping, iliac compression, midline sacral thrust test, Gaenslen's test, and Patrick s test were used as gold standard. Both SJ were examined with Doppler ultrasound (General Electric Logiq 9, Wauwatosa WI, USA) fitted with a 9-14 Mhz lineal probe. The ultrasonographer was blinded to clinical data. Doppler in SJ was assessed as positive when both Doppler colour and resistance index (RI) < 0.75 within the SJ area were present. Statistical analysis was performed estimating sensitivity and specificity against gold standard. The Kappa correlation coefficient was used for reliability study. Results: 106 cases (53 female, 55 male; mean age 36 10 years) were studied. There were no statistical differences between groups related to age or sex. Physical examination of SJ was positive in 38 patients (59 sacroiliac joints). US detected Doppler signal within SJ in 37 patients (58 SJ): 33 of them were symptomatic SpA (52 SJ), one of them were asymptomatic SpA (1 SJ) and one was a healthy control (1 SJ). The accuracy of US when compared to clinical data as gold standard at subject level in the overall group was: sensitivity of 68.6% and specificity of 85.7%, positive predictive value of 70.5% and negative predictive value of 84.5%. A positive likelihood ratio of 4.8, a negative likelihood ratio of 0.36 and a kappa coefficient of 0.55 were achieved. Conclusions: Doppler US of SJ seems to be a valid method to detect active SJ inflammation. Disclosure statement: The authors have declared no conflicts of interes
    • …
    corecore