17 research outputs found

    The Relationship of the Subclavius Muscle with Relevance to Venous Cannulation below the Clavicle

    Get PDF
    Introduction. The catheter “pinch-off syndrome” has been described to be secondary to crimping of the catheter between the clavicle and the first rib, as well as entrapment of the catheter at the site of penetration of the subclavius muscle. The lateral insertion technique has been recommended to prevent catheter pinch-off, but it is unknown if this technique can prevent entrapment by the subclavius muscle. We undertook this study to evaluate the anatomical relationship of the subclavius muscle and the subclavian vein. Methods. Twenty-eight adult cadavers were studied on both right and left sides. The adherence between the subclavian vein and subclavius muscle was subjectively assessed and the distance between the two structures was measured in mm. Results. The subclavius muscle and subclavian vein were tightly adherent in 72% of specimens, partly adherent in 14% with a mean distance of 4.5 mm and loosely connected in 14% with a mean distance of 6.1 mm. Conclusions. The anatomical relationship between the subclavius muscle and vein was very close in the majority of specimens, suggesting that the lateral insertion technique may not prevent penetration of the muscle, which may contribute to catheter pinch-off. The real-time ultrasound-guided technique may prevent penetration of the subclavius muscle

    What is an Appropriate Way to Educate Using Simulators for Ultrasound-guided Central Venous Catheterization?

    No full text

    Shallow-angle needle guide for ultrasound-guided internal jugular venous catheterization: A randomized controlled crossover simulation study (CONSORT).

    No full text
    BackgroundNeedle guides for ultrasound-guided internal jugular venous catheterization facilitate successful cannulation. The ability of a needle guide to prevent a posterior vein wall injury which may secondarily induce lethal complications, is unknown. Previous studies showed that a shallow angle of approach may reduce the incidence of posterior wall injuries. We developed a novel needle guide with a shallow angle of approach for ultrasound-guided venous catheterization and examined whether this needle guide reduces the incidence of posterior wall injuries compared to a conventional needle guide and free-hand placement in a simulated vein.MethodsThis study was a randomized crossover-controlled trial. The primary outcome was the rate of posterior vein wall injuries. Participants had a didactic lecture about three ultrasound-guided techniques using the short-axis out-of-plane approach, including free-hand (P-free), a commercial needle guide (P-com), and a novel needle guide (P-sha). The view inside a simulated vein was recorded during venipuncture.ResultsThirty-five residents participated in this study. Posterior vein wall injuries occurred in 66% using P-free, 60% using P-com, and 0% using P-sha (pConclusionsUse of a shallow angle of approach needle guide resulted in a lower rate of posterior vein injuries during venipuncture of a simulated vein compared with other techniques using a steeper angle techniques

    Bladder Explosion during Transurethral Resection of the Prostate with Nitrous Oxide Inhalation

    Get PDF
    Bladder explosions are a rare complication of transurethral resection of the prostate. We report a patient who suffered a bladder rupture following transurethral resection of the prostate. Although explosive gases accumulate during the procedure, a high concentration of oxygen is needed to support an explosion. This rare phenomenon can be prevented by preventing the flow of room air into the bladder during the procedure to maintain a low concentration of oxygen inside the bladder

    Inadvertent catheter misplacement into the subclavian artery during ultrasound-guided internal jugular venous catheterization: a case report

    No full text
    Abstract Background Ultrasound-guided central venous catheterization has become a standard procedure. However, mechanical complications are still reported. Case presentation An 85-year-old woman presented with coagulopathic bladder tamponade. Ultrasound-guided right internal jugular venous catheterization was planned because of difficult peripheral venous access. A guidewire was advanced through a needle inserted at the midpoint of the right carotid triangle. The guidewire was identified in the short axis, but not in the long-axis ultrasound view, leading to inadvertent insertion of the catheter into the right subclavian artery through the internal jugular vein. Stent graft insertion was performed for perforation closure. The patient exhibited no symptoms of cerebral ischemia following stent graft insertion. Discussion This case demonstrated that the needle-sticking site should not be placed close to the clavicle for ultrasound-guided internal jugular venous catheterization, as it may not confirm the position of guidewire in the long-axis ultrasound view

    Iatrogenic carpal tunnel syndrome induced by wrist extension for placement of an indwelling radial artery catheter: a case report

    No full text
    Abstract A 38-year-old man with pancreatic cancer was scheduled to undergo pancreaticoduodenectomy. He had an unremarkable past medical history. After inducing general anesthesia, a left radial arterial catheter was successfully placed at first attempt. A wrist splint was used to obtain good arterial pulse waveforms. After the operation, he was transferred to the intensive care unit. The radial artery catheter was removed on the fourth postoperative day. He experienced numbness and a tingling sensation in the left thumb, the second and third fingers, and the lateral half of the fourth finger. He was diagnosed with carpal tunnel syndrome. Diagnostic imaging revealed a swollen median nerve, but no hematoma or injury. Some studies have suggested that excessive extension of the wrist may cause neuropathy. We recommend that patients’ wrists not be over-extended, even if good arterial waveforms cannot be obtained

    A Shallow Angle Short-Axis Out-of-Plane Approach Reduces the Rate of Posterior Wall Injuries in Central Venous Catheterization: A Simulation Study

    No full text
    The short-axis out-of-plane approach (SAX-OOP) is commonly used in ultrasound-guided internal jugular vein catheterization. However, this approach has a risk of posterior vein wall injuries. The authors hypothesized that a shallow angle of approach may reduce the rate of posterior wall injuries compared with the conventional steep angle approach. The present study aimed to evaluate whether a difference in the angle of approach of the needle affects the rate of posterior wall injuries. The present study was a randomized crossover-controlled trial involving 40 medical residents, conducted in the clinical training center at a hospital with a residency program. The primary outcome measure was the rate of posterior vessel wall injuries. Subjects received a didactic lecture during which the instructors taught three SAX-OOP techniques including the conventional free-hand method (procedure C), a needle navigation system (procedure N), and a shallow puncture angle using a guidance system (procedure S). Participants were trained in these approaches under supervision and each technique tested in a simulation environment. Thirty-four of 40 residents had no previous experience with central venous catheterization and were included in the final analysis. The rate of posterior vessel wall injuries in procedure S (9%) was significantly lower than using the other approaches (procedure C, 53%; procedure N, 41%). In conclusion, a shallow angle of approach using the SAX-OOP technique resulted in significantly fewer posterior vein wall injuries in central venous catheterization compared with steep angle techniques
    corecore