12 research outputs found

    Morphologic Changes of the Intervertebral Disk During Growth

    Get PDF
    Study Design. Cross-sectional. Objective. The aim of this study was to describe morphologic changes of the annulus fibrosus (AF) and nucleus pulposus (NP) in children during growth using magnetic resonance imaging. Summary of Background Data. Little is known of intervertebral disk (IVD) maturation as opposed to degeneration, such as changes in relative AF/NP proportions and orientation during growth. Studies suggest that IVD plays a role in the etiology of pediatric spinal deformities. Therefore, understanding the morphologic development of the AF and NP during growth is key. Materials and Methods. An existing database of children aged 0 to 18 that had magnetic resonance imaging for indications unrelated to the spine were analyzed. The AF/NP were segmented semiautomatically from T1 to L5. The parameters: mean IVD height, cross-sectional area, slenderness (height/width ratio), volume (ratio), and relative position of the centroid of the NP within the IVD in three directions (x, y, z) were extracted, and compared between age, sex, and spinal level. Results. IVD height increased modestly and predominantly in the low-thoracic and lumbar spine during the first 5 to 10 years of life. Cross-sectional area and thus volume increased steadily at all levels throughout growth. IVD slenderness decreased sharply in the first years of life and remains relatively stable throughout the remainder of growth. IVDs were smaller and more slender in females, especially in the mid-thoracic spine at early adolescence. In the upper-thoracic and mid-thoracic spine the NP comprises 10% to 12% of total IVD volume during growth, this percentage increases in the low-thoracic and lumbar spine towards 20% to 25%. In the anterior-posterior direction, the position of the nucleus increasingly shifts with age, possibly in line with the developing sagittal profile of the spine. Conclusion. This study describes the development of thoracic and lumbar IVDs during growth and may be used as a reference for future studies on the role of IVD in the etiology of disk-related disorders

    Acetabular rim extension using a personalized titanium implant for treatment of hip dysplasia in dogs: short-term results

    Get PDF
    Hip dysplasia (HD) is a common orthopedic problem in young dogs. To decrease the laxity of the hip joint related to HD, the surgical treatments are recommended to increase femoral head coverage. ACEtabular rim eXtension (ACE-X) using a personalized 3-dimensional printed titanium shelf implant is a new surgical treatment to increase femoral head coverage and decrease laxity of the dysplastic hip joint, however, the efficacy is less know. Client-owned dogs older than 6 months with clinical signs of coxofemoral joint subluxation and radiographic evidence of HD with no or mild osteoarthritis (OA) were included. The Norberg angle (NA), linear percentage of femoral head overlap (LFO), and percentage of femoral head coverage (PC) were investigated radiographically and with computed tomography (CT) before and after surgery. OA was graded (scores 0–3) according to the maximum osteophyte size measured on CT. In addition, joint laxity (Ortolani) test results, gait analysis, and the Helsinki chronic pain index (HCPI) questionnaire were obtained at preoperative, immediately postoperative and at 1.5- and 3-month evaluations. Acetabular rim extension was performed in 61 hips of 34 dogs; NA, LFO, and PC were significantly higher immediately postoperatively and at the 1.5- and 3-month follow-up examinations compared with preoperative values (p < 0.05). Osteophyte size gradually increased over time (p < 0.05). The OA score significantly increased between preoperatively and directly postoperatively, and between preoperatively and at 3-month follow-up (p < 0.05). The laxity test normalized in 59 out of 61 hips after surgery, and the HCPI questionnaire showed that the pain score decreased significantly at 1.5 and 3 months, postoperatively. The force plate showed no significant improvement during the 3 months follow-up. Although pain reduction by the implant was unclear in short-term results, a personalized shelf implant significantly increased femoral head coverage and eliminated subluxation of the dysplastic hip joint. Further studies are required to study the long-term efficacy of gait, chronic pain, and progression of osteoarthritis

    Prediction of the Proximal Humerus Morphology Based on a Statistical Shape Model with Two Parameters: Comparison to Contralateral Registration Method

    Get PDF
    (1) Background: Complex proximal humerus fractures often result in complications following surgical treatment. A better understanding of the full 3D displacement would provide insight into the fracture morphology. Repositioning of fracture elements is often conducted by using the contralateral side as a reconstruction template. However, this requires healthy contralateral anatomy. The purpose of this study was to create a Statistical Shape Model (SSM) and compare its effectiveness to the contralateral registration method for the prediction of the humeral proximal segment; (2) Methods: An SSM was created from 137 healthy humeri. A prediction for the proximal segment of the left humeri from eight healthy patients was made by combining the SSM with parameters. The predicted proximal segment was compared to the left proximal segment of the patients. Their left humerus was also compared to the contralateral (right) humerus; (3) Results: Eight modes explained 95% of the variation. Most deviations of the SSM prediction and the contralateral registration method were below the clinically relevant 2 mm distance threshold.; (4) Conclusions: An SSM combined with parameters is a suitable method to predict the proximal humeral segment when the contralateral CT scan is unavailable or the contralateral humerus is unhealthy, provided that the fracture pattern allows measurements of these parameters

    Cochlear implant positioning: development and validation of an automatic method using computed tomography image analysis

    Get PDF
    UNLABELLED: The aim of this study was to preoperatively asses the feasibility of drilling a bony recess for the fixation of a cochlear implant in the temporal bone. Even though complications are rare with cochlear implantations, drilling at the site of implantation have resulted in hematoma or cerebrospinal fluid leakage. Mainly in cases with a reduced temporal bone thickness, the risk for complications has increased, such as in paediatric patients. METHODS: An in-house designed semi-automatic algorithm was developed to analyse a 3D model of the skull. The feasibility of drilling the recess was determined by a gradient descent method to search for the thickest part of the temporal bone. Feasibility was determined by the residual bone thickness which was calculated after a simulated drilling of the recess at the thickest position. An initial validation of the algorithm was performed by measuring the accuracy of the algorithm on five 3D models with known thickest locations for the recess. The accuracy was determined by a part comparison between the known position and algorithm provided position. RESULTS: In four of the five validation models a standard deviation for accuracy below the predetermined cut-off value of 4.2 mm was achieved between the actual thickest position and the position determined by the algorithm. Furthermore, the residual thickness calculated by the algorithm showed a high agreement (max. 0.02 mm difference) with the actual thickness. CONCLUSION: With the developed algorithm, a semi-automatic method was created to analyse the temporal bone thickness within a specified region of interest on the skull. Thereby, providing indications for surgical feasibility, potential risks for anatomical structures and impact on procedure time of cochlear implantation. This method could be a valuable research tool to objectively assess feasibility of drilling a recess in patients with thin temporal bones preoperatively

    Surgical Technique of the 3-Dimensional-printed Personalized Hip Implant for the Treatment of Canine Hip Dysplasia

    Get PDF
    Hip dysplasia causes major disability in dogs. Treatment options are limited to palliative treatment (e.g., pain relief, physical exercise, lifestyle changes, and weight control) or invasive surgeries such as pelvic osteotomies and total hip arthroplasty. Hence, a strong unmet need exists for an effective and dog-friendly solution that enhances the quality of life of man's best friend. We fill this treatment gap by offering a minimally traumatic and extraarticular, dog-specific, 3-dimensional-printed, hip implant (3DHIP) that restores hip joint stability. The surgical treatment using a 3DHIP implant is less invasive than osteotomies and can be performed bilaterally in one surgical session. The 3DHIP implant extends the dorsal acetabular rim of the dysplastic hip joint thereby increasing coverage of the femoral head and inhibiting joint subluxation with fast recovery. Sufficient access to the dorsal acetabular rim and ventral border of the iliac body together with optimal fitting and fixation of the implant are key steps for a successful 3DHIP implantation and imply the need for a specific approach. The present article aims to showcase this innovative surgical technique with tips and tricks as a surgical manual for implantation of the 3DHIP implant in dogs affected by hip dysplasia

    Surgical Technique of the 3-Dimensional-printed Personalized Hip Implant for the Treatment of Canine Hip Dysplasia

    Get PDF
    Hip dysplasia causes major disability in dogs. Treatment options are limited to palliative treatment (e.g., pain relief, physical exercise, lifestyle changes, and weight control) or invasive surgeries such as pelvic osteotomies and total hip arthroplasty. Hence, a strong unmet need exists for an effective and dog-friendly solution that enhances the quality of life of man's best friend. We fill this treatment gap by offering a minimally traumatic and extraarticular, dog-specific, 3-dimensional-printed, hip implant (3DHIP) that restores hip joint stability. The surgical treatment using a 3DHIP implant is less invasive than osteotomies and can be performed bilaterally in one surgical session. The 3DHIP implant extends the dorsal acetabular rim of the dysplastic hip joint thereby increasing coverage of the femoral head and inhibiting joint subluxation with fast recovery. Sufficient access to the dorsal acetabular rim and ventral border of the iliac body together with optimal fitting and fixation of the implant are key steps for a successful 3DHIP implantation and imply the need for a specific approach. The present article aims to showcase this innovative surgical technique with tips and tricks as a surgical manual for implantation of the 3DHIP implant in dogs affected by hip dysplasia

    Acetabular rim extension using a personalized titanium implant for treatment of hip dysplasia in dogs: short-term results

    Get PDF
    Hip dysplasia (HD) is a common orthopedic problem in young dogs. To decrease the laxity of the hip joint related to HD, the surgical treatments are recommended to increase femoral head coverage. ACEtabular rim eXtension (ACE-X) using a personalized 3-dimensional printed titanium shelf implant is a new surgical treatment to increase femoral head coverage and decrease laxity of the dysplastic hip joint, however, the efficacy is less know. Client-owned dogs older than 6 months with clinical signs of coxofemoral joint subluxation and radiographic evidence of HD with no or mild osteoarthritis (OA) were included. The Norberg angle (NA), linear percentage of femoral head overlap (LFO), and percentage of femoral head coverage (PC) were investigated radiographically and with computed tomography (CT) before and after surgery. OA was graded (scores 0–3) according to the maximum osteophyte size measured on CT. In addition, joint laxity (Ortolani) test results, gait analysis, and the Helsinki chronic pain index (HCPI) questionnaire were obtained at preoperative, immediately postoperative and at 1.5- and 3-month evaluations. Acetabular rim extension was performed in 61 hips of 34 dogs; NA, LFO, and PC were significantly higher immediately postoperatively and at the 1.5- and 3-month follow-up examinations compared with preoperative values (p < 0.05). Osteophyte size gradually increased over time (p < 0.05). The OA score significantly increased between preoperatively and directly postoperatively, and between preoperatively and at 3-month follow-up (p < 0.05). The laxity test normalized in 59 out of 61 hips after surgery, and the HCPI questionnaire showed that the pain score decreased significantly at 1.5 and 3 months, postoperatively. The force plate showed no significant improvement during the 3 months follow-up. Although pain reduction by the implant was unclear in short-term results, a personalized shelf implant significantly increased femoral head coverage and eliminated subluxation of the dysplastic hip joint. Further studies are required to study the long-term efficacy of gait, chronic pain, and progression of osteoarthritis

    Cochlear implant positioning: development and validation of an automatic method using computed tomography image analysis

    Get PDF
    The aim of this study was to preoperatively asses the feasibility of drilling a bony recess for the fixation of a cochlear implant in the temporal bone. Even though complications are rare with cochlear implantations, drilling at the site of implantation have resulted in hematoma or cerebrospinal fluid leakage. Mainly in cases with a reduced temporal bone thickness, the risk for complications has increased, such as in paediatric patients.MethodsAn in-house designed semi-automatic algorithm was developed to analyse a 3D model of the skull. The feasibility of drilling the recess was determined by a gradient descent method to search for the thickest part of the temporal bone. Feasibility was determined by the residual bone thickness which was calculated after a simulated drilling of the recess at the thickest position. An initial validation of the algorithm was performed by measuring the accuracy of the algorithm on five 3D models with known thickest locations for the recess. The accuracy was determined by a part comparison between the known position and algorithm provided position.ResultsIn four of the five validation models a standard deviation for accuracy below the predetermined cut-off value of 4.2 mm was achieved between the actual thickest position and the position determined by the algorithm. Furthermore, the residual thickness calculated by the algorithm showed a high agreement (max. 0.02 mm difference) with the actual thickness.ConclusionWith the developed algorithm, a semi-automatic method was created to analyse the temporal bone thickness within a specified region of interest on the skull. Thereby, providing indications for surgical feasibility, potential risks for anatomical structures and impact on procedure time of cochlear implantation. This method could be a valuable research tool to objectively assess feasibility of drilling a recess in patients with thin temporal bones preoperatively

    New implant acetabular cup: A biomechanical proof of concept

    No full text
    The management of large acetabular defects remains one of the most challenging aspects of revision total hip arthroplasties. Failure of frequently used acetabular reconstruction components are, among others, caused by the lack of biological fixation, a non-physiological stress distribution and stress-shielding. Attempting to diminish these drawbacks of current implants a new acetabular cup has been explored. The double layer of this new acetabular cup better fills the acetabular defect. According to Wolff’s law this should reduce stress shielding and stimulate bone ingrowth. Part one of this study explores the relationship between unit cell size of the titanium and mechanical properties for the body centred cubic unit cell. Three graded lattices using different unit cell sizes were designed and 3D-printed out of commercially pure titanium (Grade 1) using selective laser melting. An unconfined compression test with cylindrical samples as well as a confined compression test with hemispherical samples were performed to obtain mechanical properties. An additional finite element study was used to validate the confined compression test. Acetabular defects were made in five Sawbones hemipelves which served as the basis for the design of the ‘patient specific’ acetabular cups. Three triflange and two unflanged acetabular cups were designed and 3D-printed out of commercially pure titanium (Grade 1) using selective laser melting. Mechanical properties were obtained from the unconfined compression tests. All acetabular cups were inserted by two orthopaedic surgeons at the UMC Utrecht. Cyclic testing was performed up to 1000 cycles to assess femoral head penetration under load after insertion. Additional penetration of the femoral head was found to be between 0.1781 and 0.3793 mm. Future work is needed to prevent strut breakage upon insertion and more research is needed in the fatigue behaviour of these new cups and their biological effect on living bone tissue.Biomedical Engineerin

    Prediction of the Proximal Humerus Morphology Based on a Statistical Shape Model with Two Parameters:Comparison to Contralateral Registration Method

    No full text
    (1) Background: Complex proximal humerus fractures often result in complications following surgical treatment. A better understanding of the full 3D displacement would provide insight into the fracture morphology. Repositioning of fracture elements is often conducted by using the contralateral side as a reconstruction template. However, this requires healthy contralateral anatomy. The purpose of this study was to create a Statistical Shape Model (SSM) and compare its effectiveness to the contralateral registration method for the prediction of the humeral proximal segment; (2) Methods: An SSM was created from 137 healthy humeri. A prediction for the proximal segment of the left humeri from eight healthy patients was made by combining the SSM with parameters. The predicted proximal segment was compared to the left proximal segment of the patients. Their left humerus was also compared to the contralateral (right) humerus; (3) Results: Eight modes explained 95% of the variation. Most deviations of the SSM prediction and the contralateral registration method were below the clinically relevant 2 mm distance threshold.; (4) Conclusions: An SSM combined with parameters is a suitable method to predict the proximal humeral segment when the contralateral CT scan is unavailable or the contralateral humerus is unhealthy, provided that the fracture pattern allows measurements of these parameters.</p
    corecore