58 research outputs found
The sense of music education in education conceived as an engine of the knowledge economy: a philosophical framework proposal
Changes produced by the Knowledge-based Society and Economy have an influence on educational policies, attaching less importance to arts and music education within the curriculum. This article offers a literature review on present music education, where two opposite perspectives were found in: economic and social. The latter educational perspective aims the development of multiple human aspects in order to participate in current society. Music contributes to this goal, generating knowledge and action by means of it. To achieve this, philosophical thinking on music education, able to give fundament to music education and to respond to relevant topics for current education, should be elaborated
Compact analytical flow system for the simultaneous determination of L-lactic and L-malic in red wines
During the malolactic fermentation of red wines, L-malic acid is mainly converted to L-lactic acid. Both acids should be precisely measured during the entire process to guarantee the quality of the final wine, thus making real-time monitoring approaches of great importance in the winemaking industry. Traditional analytical methods based on laboratory procedures are currently applied and cannot be deployed on-site. In this work, we report on the design and development of a bi-parametric compact analytical flow system integrating two electrochemical biosensors that could be potentially applied in this scenario. The developed flow-system will allow for the first time the simultaneous measurement of both acids in real scenarios at the real-time and in remote way. Miniaturized thin-film platinum four-electrode chips are fabricated on silicon substrates by standard photolithographic techniques and further implemented in a polymeric fluidic structure. This includes a 15 µL flow cell together with the required fluidic channels for sample and reagent fluid management. The four-electrode chip includes counter and pseudo-reference electrodes together with two working electrodes. These are sequentially modified with electropolymerized polypyrrole membranes that entrap the specific receptors for selectively detecting both target analytes. The analytical performance of both biosensors is studied by chronoamperometry, showing a linear range from 5 × 10−6 to 1 × 10−4 M (LOD of 3.2 ± 0.3 × 10−6 M) and from 1 × 10−7 to 1 × 10−6 M (LOD of 6.7 ± 0.2 × 10−8 M) for the L-lactate and the L-malate, respectively. Both biosensors show long-term stability, retaining more than the 90% of their initial sensitivity after more than 30 days, this being a prerequisite for monitoring the whole process of the malolactic fermentation of the red wines (time between 20 and 40 days). The flow system performance is assessed with several wine samples collected during the malolactic fermentation process of three red wines, showing an excellent agreement with the results obtained with the standard method.info:eu-repo/semantics/publishedVersio
Portable Electronic Tongue Based on Microsensors for the Analysis of Cava Wines
Cava is a quality sparkling wine produced in Spain. As a product with a designation of origin, Cava wine has to meet certain quality requirements throughout its production process; therefore, the analysis of several parameters is of great interest. In this work, a portable electronic tongue for the analysis of Cava wine is described. The system is comprised of compact and low-power-consumption electronic equipment and an array of microsensors formed by six ion-selective field effect transistors sensitive to pH, Na+, K+, Ca2+, Cl−, and CO32−, one conductivity sensor, one redox potential sensor, and two amperometric gold microelectrodes. This system, combined with chemometric tools, has been applied to the analysis of 78 Cava wine samples. Results demonstrate that the electronic tongue is able to classify the samples according to the aging time, with a percentage of correct prediction between 80% and 96%, by using linear discriminant analysis, as well as to quantify the total acidity, pH, volumetric alcoholic degree, potassium, conductivity, glycerol, and methanol parameters, with mean relative errors between 2.3% and 6.0%, by using partial least squares regressions.We acknowledge funding from the Spanish R & D National Program (MINECO, Projects
TEC2011-29045-C04-01 and TEC2014-54449-C3-1-R). P.G.-G. is grateful to MINECO, Spain, for the financial
support through a research studentship of the FPI Program. We acknowledge support by the CSIC Open Access Publication Initiative through its Unit of Information Resources for Research (URICI)
Application of an E-Tongue to the Analysis of Monovarietal and Blends of White Wines
This work presents a multiparametric system capable of characterizing and classifying white wines according to the grape variety and geographical origin. Besides, it quantifies specific parameters of interest for quality control in wine. The system, known as a hybrid electronic tongue, consists of an array of electrochemical microsensors-six ISFET based sensors, a conductivity sensor, a redox potential sensor and two amperometric electrodes, a gold microelectrode and a microelectrode for sensing electrochemical oxygen demand-and a miniaturized optofluidic system. The test sample set comprised eighteen Catalan monovarietal white wines from four different grape varieties, two Croatian monovarietal white wines and seven bi- and trivarietal mixtures prepared from the Catalan varieties. Different chemometric tools were used to characterize (i.e., Principal Component Analysis), classify (i.e., Soft Independent Modeling Class Analogy) and quantify (i.e., Partial-Least Squares) some parameters of interest. The results demonstrate the usefulness of the multisensor system for analysis of wine
Hybrid Electronic Tongues Applied to the Quality Control of Wines
The legislation of food industry is becoming increasingly strict with regard to the quality of food products. Therefore, the market is demanding for automatic systems of analysis that allow fast and accurate monitoring of the evolution of quality parameters in agrofood products or permit obtaining information to optimize production processes. In this context, sensors and more specifically microsensors play an important role since they allow fast and reproducible measurement of a large number of quality parameters with good reliability and can be implemented in portable systems. This paper presents a review of the results obtained with an electronic tongue based on different kinds of microsensors applied to wine analysis by the team of IMB-CNM. This multisensor system allows on one hand classifying the wine according to its features like grape variety, geographic origin, year, and organoleptic characteristics and on the other hand quantifying some parameters of interest in quality control, such as alcoholic degree, pH, ions, total acidity, glycerol, and color
Multisensing wearables for real-time monitoring of sweat electrolyte biomarkers during exercise and analysis on their correlation with core body temperature
Sweat secreted by the human eccrine sweat glands can provide valuable biomarker information during exercise. Real-time non-invasive biomarker recordings are therefore useful for evaluating the physiological conditions of an athlete such as their hydration status during endurance exercise. This work describes a wearable sweat biomonitoring patch incorporating printed electrochemical sensors into a plastic microfluidic sweat collector and data analysis that shows the real-time recorded sweat biomarkers can be used to predict a physiological biomarker. The system was placed on subjects carrying out an hour-long exercise session and results were compared to a wearable system using potentiometric robust silicon-based sensors and to commercially available HORIBA-LAQUAtwin devices. Both prototypes were applied to the real-time monitoring of sweat during cycling sessions and showed stable readings for around an hour. Analysis of the sweat biomarkers collected from the printed patch prototype shows that their real-time measurements correlate well (correlation coefficient ≥0.65 ) with other physiological biomarkers such as heart rate and regional sweat rate collected in the same session. We show for the first time, that the real-time sweat sodium and potassium concentration biomarker measurements from the printed sensors can be used to predict the core body temperature with root mean square error (RMSE) of 0.02 °C which is 71% lower compared to the use of only the physiological biomarkers. These results show that these wearable patch technologies are promising for real-time portable sweat monitoring analytical platforms, especially for athletes performing endurance exercise
Assessing the performance of a robust multiparametric wearable patch integrating silicon-based sensors for real-time continuous monitoring of sweat biomarkers
The development of wearable devices for sweat analysis has experienced significant growth in the last two decades, being the main focus the monitoring of athletes health during workouts. One of the main challenges of these approaches has been to attain the continuous monitoring of sweat for time periods over 1 h. This is the main challenge addressed in this work by designing an analytical platform that combines the high performance of potentiometric sensors and a fluidic structure made of a plastic fabric into a multiplexed wearable device. The platform comprises Ion-Sensitive Field-Effect Transistors (ISFETs) manufactured on silicon, a tailor-made solid-state reference electrode, and a temperature sensor integrated into a patch-like polymeric substrate, together with the component that easily collects and drives samples under continuous capillary flow to the sensor areas. ISFET sensors for measuring pH, sodium, and potassium ions were fully characterized in artificial sweat solutions, providing reproducible and stable responses. Then, the real-time and continuous monitoring of the biomarkers in sweat with the wearable platform was assessed by comparing the ISFETs responses recorded during an 85-min continuous exercise session with the concentration values measured using commercial Ion-Selective Electrodes (ISEs) in samples collected at certain times during the session. The developed sensing platform enables the continuous monitoring of biomarkers and facilitates the study of the effects of various real working conditions, such as cycling power and skin temperature, on the target biomarker concentration levels.This work was performed within the WeCare project, funded by the Swiss National Science Foundation (SNSF, Sinergia Program, Project CRSIIS_177255/1) and used the ICTS Network MICRONANOFABS supported by the Spanish Ministry of Science and Innovation. We would also like to thank Miwon, South Corea and Allnex for providing photocurable polymers. The authors acknowledge the participation in the Electrobionet network (ref. RED2022-134120-T) funded by MICIN/AEI/10.13039/501100011033).With funding from the Spanish government through the ‘María de Maeztu Unit of Excelence accreditation (CEX2023- 001397-M).Peer reviewe
Reconfigurable multiplexed point of Care System for monitoring type 1 diabetes patients
At the point of care (POC), on-side clinical testing allows fast biomarkers determination even in resource-limited environments. Current POC systems rely on tests selective to a single analyte or complex multiplexed systems with important portability and performance limitations. Hence, there is a need for handheld POC devices enabling the detection of multiple analytes with accuracy and simplicity. Here we present a reconfigurable smartphone-interfaced electrochemical Lab-on-a-Chip (LoC)with two working electrodes for dual analyte determination enabling biomarkers' selection in situ and on-demand. Biomarkers selection was achieved by the use of electrodepositable alginate hydrogels. Alginate membranes containing either glucose oxidase (GOx)or lactate oxidase (LOx)were selectively electrodeposited on the surface of each working electrode in around 4 min, completing sample measurement in less than 1 min. Glucose and lactate determination was performed simultaneously and without cross-talk in buffer, fetal bovine serum (FBS)and whole blood samples, the latter being possible by the size-exclusion filtration capacity of the hydrogels. At optimal conditions, glucose and lactate were determined in a wide linear range (0–12 mM and 0–5 mM, respectively)and with high sensitivities (0.24 and 0.54 μA cm −2 mM −1 , respectively), which allowed monitoring of Type-1 diabetic patients with a simple dual analysis system. After the measurement, membranes were removed by disaggregation with the calcium-chelator phosphate buffer. At this point, new membranes could be electrodeposited, this time being selective to the same or another analyte. This conferred the system with on-demand biomarkers’ selection capacity. The versatility and flexibility of the current architecture is expected to impact in POC analysis in applications ranging from homecare to sanitary emergencies.Peer reviewe
Ultramicroelectrode Array Based Sensors: A Promising Analytical Tool for Environmental Monitoring
The particular analytical performance of ultramicroelectrode arrays (UMEAs) has attracted a high interest by the research community and has led to the development of a variety of electroanalytical applications. UMEA-based approaches have demonstrated to be powerful, simple, rapid and cost-effective analytical tools for environmental analysis compared to available conventional electrodes and standardised analytical techniques. An overview of the fabrication processes of UMEAs, their characterization and applications carried out by the Spanish scientific community is presented. A brief explanation of theoretical aspects that highlight their electrochemical behavior is also given. Finally, the applications of this transducer platform in the environmental field are discussed
Multisensing Wearables for Real-Time Monitoring of Sweat Electrolyte Biomarkers During Exercise and Analysis on Their Correlation With Core Body Temperature
Sweat secreted by the human eccrine sweat glands can provide valuable biomarker information during exercise. Real-time non-invasive biomarker recordings are therefore useful for evaluating the physiological conditions of an athlete such as their hydration status during endurance exercise. This work describes a wearable sweat biomonitoring patch incorporating printed electrochemical sensors into a plastic microfluidic sweat collector and data analysis that shows the real-time recorded sweat biomarkers can be used to predict a physiological biomarker. The system was placed on subjects carrying out an hour-long exercise session and results were compared to a wearable system using potentiometric robust silicon-based sensors and to commercially available HORIBA-LAQUAtwin devices. Both prototypes were applied to the real-time monitoring of sweat during cycling sessions and showed stable readings for around an hour. Analysis of the sweat biomarkers collected from the printed patch prototype shows that their real-time measurements correlate well (correlation coefficient ≥ 0.65) with other physiological biomarkers such as heart rate and regional sweat rate collected in the same session. We show for the first time, that the real-time sweat sodium and potassium concentration biomarker measurements from the printed sensors can be used to predict the core body temperature with root mean square error (RMSE) of 0.02 °C which is 71% lower compared to the use of only the physiological biomarkers. These results show that these wearable patch technologies are promising for real-time portable sweat monitoring analytical platforms, especially for athletes performing endurance exercise.Peer reviewe
- …