23 research outputs found
The association of polypharmacy and high-risk drug classes with adverse health outcomes in the Scottish population with type 1 diabetes
This study was supported by funding from the Diabetes UK (17/0005627). The funder had no role in designing the study or in analysing and interpreting data and results.Aims/hypothesis The aim of this work was to map the number of prescribed drugs over age, sex and area-based socioeconomic deprivation, and to examine the association between the number of drugs and particular high-risk drug classes with adverse health outcomes among a national cohort of individuals with type 1 diabetes. Methods Utilising linked healthcare records from the population-based diabetes register of Scotland, we identified 28,245 individuals with a diagnosis of type 1 diabetes on 1 January 2017. For this population, we obtained information on health status, predominantly reflecting diabetes-related complications, and information on the total number of drugs and particular high-risk drug classes prescribed. We then studied the association of these baseline-level features with hospital admissions for falls, diabetic ketoacidosis (DKA), and hypoglycaemia or death within the subsequent year using multivariate Cox proportional hazards models. Results Not considering insulin and treatment for hypoglycaemia, the mean number of prescribed drugs was 4.00 (SD 4.35). The proportion of individuals being prescribed five or more drugs at baseline consistently increased with age (proportion [95% CI]: 0ā19Ā years 2.04% [1.60, 2.49]; 40ā49Ā years 28.50% [27.08, 29.93]; 80+ years 76.04% [67.73, 84.84]). Controlling for age, sex, area-based socioeconomic deprivation and health status, each additional drug at baseline was associated with an increase in the hazard for hospitalisation for falls, hypoglycaemia and death but not for DKA admissions (HR [95% CI]: falls 1.03 [1.01, 1.06]; DKA 1.01 [1.00, 1.03]; hypoglycaemia 1.05 [1.02, 1.07]; death 1.04 [1.02, 1.06]). We found a number of drug classes to be associated with an increased hazard of one or more of these adverse health outcomes, including antithrombotic/anticoagulant agents, corticosteroids, opioids, antiepileptics, antipsychotics, hypnotics and sedatives, and antidepressants. Conclusions Polypharmacy is common among the Scottish population with type 1 diabetes and is strongly patterned by sociodemographic factors. The number of prescribed drugs and the prescription of particular high-risk drug classes are strong markers of an increased risk of adverse health outcomes, including acute complications of diabetes.Publisher PDFPeer reviewe
Glycaemic control trends in people with Type 1 diabetes in Scotland 2004-2016
Aims/hypothesis:
The aim of this work was to examine whether glycaemic control has improved in those with type 1 diabetes in Scotland between 2004 and 2016, and whether any trends differed by sociodemographic factors.
Methods:
We analysed records from 30,717 people with type 1 diabetes, registered anytime between 2004 and 2016 in the national diabetes database, which contained repeated measures of HbA1c. An additive mixed regression model was used to estimate calendar time and other effects on HbA1c.
Results:
Overall, median (IQR) HbA1c decreased from 72 (21) mmol/mol [8.7 (4.1)%] in 2004 to 68 (21) mmol/mol (8.4 [4.1]%) in 2016. However, all of the improvement across the period occurred in the latter 4 years: the regression model showed that the only period of significant change in HbA1c was 2012ā2016 where there was a fall of 3 (95% CI 1.82, 3.43) mmol/mol. The largest reductions in HbA1c in this period were seen in children, from 69 (16) mmol/mol (8.5 [3.6]%) to 63 (14) mmol/mol (7.9 [3.4]%), and adolescents, from 75 (25) mmol/mol (9.0 [4.4]%) to 70 (23) mmol/mol (8.6 [4.3]%). Socioeconomic status (according to Scottish Index of Multiple Deprivation) affected the HbA1c values: from the regression model, the 20% of people living in the most-deprived areas had HbA1c levels on average 8.0 (95% CI 7.4, 8.9) mmol/mol higher than those of the 20% of people living in the least-deprived areas. However this difference did not change significantly over time. From the regression model HbA1c was on average 1.7 (95% CI 1.6, 1.8) mmol/mol higher in women than in men. This sex difference did not narrow over time.
Conclusions/interpretation:
In this high-income country, we identified a modest but important improvement in HbA1c since 2012 that was most marked in children and adolescents. These changes coincided with national initiatives to reduce HbA1c including an expansion of pump therapy. However, in most people, overall glycaemic control remains far from target levels and further improvement is badly needed, particularly in those from more-deprived areas
Marked improvements in glycaemic outcomes following insulin pump therapy initiation in people with type 1 diabetes:a nationwide observational study in Scotland
This study was supported by funding from Diabetes UK (17/0005627) and the Chief Scientist Office (ref. ETM/47).Aims/hypothesis Our aim was to assess the use of continuous subcutaneous insulin infusion (CSII) in people with type 1 diabetes in Scotland and its association with glycaemic control, as measured by HbA1c levels, frequency of diabetic ketoacidosis (DKA) and severe hospitalised hypoglycaemia (SHH), overall and stratified by baseline HbA1c. Methods We included 4684 individuals with type 1 diabetes from the national Scottish register, who commenced CSII between 2004 and 2019. We presented crude within-person differences from baseline HbA1c over time since initiation, crude DKA and SHH event-rates pre-/post-CSII exposure. We then used mixed models to assess the significance of CSII exposure, taking into account: (1) the diffuse nature of the intervention (i.e. structured education often precedes initiation); (2) repeated within-person measurements; and (3) background time-trends occurring pre-intervention. Results HbA1c decreased after CSII initiation, with a median within-person change of ā5.5 mmol/mol (IQR ā12.0, 0.0) (ā0.5% [IQR ā1.1, 0.0]). Within-person changes were most substantial in those with the highest baseline HbA1c, with median ā21.0 mmol/mol (ā30.0, ā11.0) (ā1.9% [ā2.7, ā1.0]) change in those with a baseline >84 mmol/mol (9.8%) within a year of exposure, that was sustained: ā19.0 mmol/mol (ā27.6, ā6.5) (ā1.7% [ā2.5, ā0.6]) at ā„5 years. Statistical significance and magnitude of change were supported by the mixed models results. The crude DKA event-rate was significantly lower in post-CSII person-time compared with pre-CSII person-time: 49.6 events (95% CI 46.3, 53.1) per 1000 person-years vs 67.9 (64.1, 71.9); rate ratio from Bayesian mixed models adjusting for pre-exposure trend: 0.61 (95% credible interval [CrI] 0.47, 0.77; posterior probability of reduction ppā=ā1.00). The crude overall SHH event-rate in post-CSII vs pre-CSII person-time was also lower: 17.8 events (95% CI 15.8, 19.9) per 1000 person-years post-exposure vs 25.8 (23.5, 28.3) pre-exposure; rate ratio from Bayesian mixed models adjusting for pre-exposure trend: 0.67 (95% CrI 0.45, 1.01; ppā=ā0.97). Conclusions/interpretation CSII therapy was associated with marked falls in HbA1c especially in those with high baseline HbA1c. CSII was independently associated with reduced DKA and SHH rates. CSII appears to be an effective option for intensive insulin therapy in people with diabetes for improving suboptimal glycaemic control.Publisher PDFPeer reviewe
Flash monitor initiation is associated with improvements in HbA1c levels and DKA rates among people with Type 1 Diabetes in Scotland:a retrospective nationwide observational study
Funding Information: This study was supported by funding from the Diabetes UK (17/0005627) and the Chief Scientist Office (Ref. ETM/47).Peer reviewedPublisher PD
Rising Rates And Widening Socio-economic Disparities In Diabetic Ketoacidosis In Type 1 Diabetes In Scotland:A Nationwide Retrospective Cohort Observational Study
OBJECTIVE:
Whether advances in the management of type 1 diabetes are reducing rates of
diabetic ketoacidosis (DKA) is unclear. We investigated time trends in DKA rates
in a national cohort of individuals with type 1 diabetes monitored for 14 years,
overall and by socioeconomic characteristics.
RESEARCH DESIGN AND METHODS:
All individuals in Scotland with type 1 diabetes who were alive and at least 1 year
old between 1 January 2004 and 31 December 2018 were identified using the
national register (N 5 37,939). DKA deaths and hospital admissions were
obtained through linkage to Scottish national death and morbidity records.
Bayesian regression was used to test for DKA time trends and association with
risk markers, including socioeconomic deprivation.
RESULTS:
There were 30,427 DKA admissions and 472 DKA deaths observed over 393,223
person-years at risk. DKA event rates increased over the study period (incidence
rate ratio [IRR] per year 1.058 [95% credibility interval 1.054ā1.061]). Males had
lower rates than females (IRR male-to-female 0.814 [0.776ā0.855]). DKA incidence rose in all age-groups other than 10- to 19-year-olds, in whom rates were
the highest, but fell over the study. There was a large socioeconomic differential
(IRR least-to-most deprived quintile 0.446 [0.406ā0.490]), which increased during
follow-up. Insulin pump use or completion of structured education were associated with lower DKA rates, and antidepressant and methadone prescription were
associated with higher DKA rates.
CONCLUSIONS:
DKA incidence has risen since 2004, except in 10- to 19-year-olds. Of particular
concern are the strong and widening socioeconomic disparities in DKA outcomes.
Efforts to prevent DKA, especially in vulnerable groups, require strengthening
Microstructure and biomechanical characteristics of bone substitutes for trauma and orthopaedic surgery
Abstract.
BACKGROUND: Many (artificial) bone substitute materials are currently available for use in orthopaedic trauma surgery. Objective data on their biological and biomechanical characteristics, which determine their clinical application, is mostly lacking. The aim of this study was to investigate structural and in vitro mechanical properties of nine bone substitute cements registered for use in orthopaedic trauma surgery in the Netherlands.
METHODS: Seven calcium phosphate cements (BoneSourceĀ®, CalcibonĀ®, ChronOSĀ®, EuroboneĀ®, HydroSetā¢, Norian SRSĀ®, and OstimĀ®), one calcium sulphate cement (MIIGĀ® X3), and one bioactive glass cement (CortossĀ®) were tested. Structural characteristics were measured by micro-CT scanning. Compression strength and stiffness were determined following unconfined compression tests.
RESULTS: Each bone substitute had unique characteristics. Mean total porosity ranged from 53% (OstimĀ®) to 0.5% (Norian SRSĀ®). Mean pore size exceeded 100 Ī¼m only in EuroboneĀ® and CortossĀ® (162.2 Ā± 107.1 Ī¼m and 148.4 Ā± 70.6 Ī¼m, respectively). However, 230 Ī¼m pores were found in CalcibonĀ®, Norian SRSĀ®, HydroSetā¢, and MIIGĀ® X3. Connectivity density ranged from 27/cm3 for HydroSetā¢ to 0.03/cm3 for CalcibonĀ®. The ultimate compression strength was highest in CortossĀ® (47.32 MPa) and lowest in OstimĀ® (0.24 MPa). Young's Modulus was highest in CalcibonĀ® (790 MPa) and lowest in OstimĀ® (6 MPa).
CONCLUSIONS: The bone substitutes tested display a wide range in structural properties and compression strength, indicating that they will be suitable for different clinical indications. The data outlined here will help surgeons to select the most suitable products currently available for specific clinical indications
Are shoulder surgeons any good at diagnosing rotator cuff tears using ultrasound?: A comparative analysis of surgeon vs radiologist
High-resolution ultrasound has gained increasing popularity as an aid in the diagonsis of rotator cuff pathology. With the advent of portable machines, ultrasound has become accessible to clincians.
Aim: this study was conducted to evaluate the accuracy and reliability of ultrasound in diagnosing rotator cuff tears by a shoulder surgeon and comparing their ability to that of a musculoskeletal radiologist.
Materials and Methods: seventy patients undergoing shoulder arthroscopy for rotator cuff pathology underwent preoperative ultrasonography (US). All patients were of similar demographics and pathology. The surgeon used a Sonosite Micromax portable ultrasound machine with a 10-MHz high frequency linear array transducer and the radiologist used a 9-12 MHz linear array probe on a Siemens Antares machine. Arthroscopic diagnosis was the reference standard to which ultrasound findings were compared.
Results: the sensitivity in detecting full thickness tears was similar for both the surgeon (92%) and the radiologist (94%). The radiologist had 100% sensitivity in diagnosing partial thickness tears, compared to 85.7% for the surgeon. The specificity for the surgeon was 94% and 85% for the radiologist.
Discussion: our study shows that the surgeons are capable of diagnosing rotator cuff tears with the use of high-resolution portable ultrasound in the outpatient setting.
Conclusion: office ultrasound, by a trained clinician, is a powerful diagnostic tool in diagnosing rotator cuff tears and can be used effectively in running one-stop shoulder clinics