7 research outputs found

    High power 404 nm source based on second harmonic generation in PPKTP of a tapered external feedback diode laser

    Get PDF
    We present results on a 404 nm laser system based on second harmonic generation in a new compact external cavity configuration. We obtain a stable 318 mW cw diffraction limited output from the system with a mode-matched pump power of 630 mW. We observe up to 620 mW SHG, when the cavity is operating in scanning mode. The pump source is an external cavity grating feedback tapered diode laser operating at 808 nm. We find that thermal effects in the nonlinear crystal severely limit the efficiency of the setup with high input powers

    Optical effects of exposing intact human lenses to ultraviolet radiation and visible light

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The human lens is continuously exposed to high levels of light. Ultraviolet radiation is believed to play a causative role in the development of cataract. In vivo, however, the lens is mainly exposed to visible light and the ageing lens absorbs a great part of the short wavelength region of incoming visible light. The aim of the present study was to examine the optical effects on human lenses of short wavelength visible light and ultraviolet radiation.</p> <p>Methods</p> <p>Naturally aged human donor lenses were irradiated with UVA (355 nm), violet (400 and 405 nm) and green (532 nm) lasers. The effect of irradiation was evaluated qualitatively by photography and quantitatively by measuring the direct transmission before and after irradiation. Furthermore, the effect of pulsed and continuous laser systems was compared as was the effect of short, intermediate and prolonged exposures.</p> <p>Results</p> <p>Irradiation with high intensity lasers caused scattering lesions in the human lenses. These effects were more likely to be seen when using pulsed lasers because of the high pulse intensity. Prolonged irradiation with UVA led to photodarkening whereas no detrimental effects were observed after irradiation with visible light.</p> <p>Conclusions</p> <p>Irradiation with visible light does not seem to be harmful to the human lens except if the lens is exposed to laser irradiances that are high enough to warrant thermal protein denaturation that is more readily seen using pulsed laser systems.</p

    Drug quantification in turbid media by fluorescence imaging combined with light-absorption correction using white Monte Carlo simulations

    No full text
    Accurate quantification of photosensitizers is in many cases a critical issue in photodynamic therapy. As a noninvasive and sensitive tool, fluorescence imaging has attracted particular interest for quantification in pre-clinical research. However, due to the absorption of excitation and emission light by turbid media, such as biological tissue, the detected fluorescence signal does not have a simple and unique dependence on the fluorophore concentration for different tissues, but depends in a complex way on other parameters as well. For this reason, little has been done on drug quantification in vivo by the fluorescence imaging technique. In this paper we present a novel approach to compensate for the light absorption in homogeneous turbid media both for the excitation and emission light, utilizing time-resolved fluorescence white Monte Carlo simulations combined with the Beer-Lambert law. This method shows that the corrected fluorescence intensity is almost proportional to the absolute fluorophore concentration. The results on controllable tissue phantoms and murine tissues are presented and show good correlations between the evaluated fluorescence intensities after the light-absorption correction and absolute fluorophore concentrations. These results suggest that the technique potentially provides the means to quantify the fluorophore concentration from fluorescence images
    corecore