601 research outputs found
Effects of stress, depression, and spousal and familial support on maternal identity in pregnant women
Purpose The objective of this study was to identify the factors influencing maternal identity in pregnant women. Methods Using a descriptive research design, a cross-sectional survey was conducted. In total, 127 pregnant women were recruited from a tertiary hospital in Korea from January to April 2019. Measurements included maternal identity, stress, depression, spousal and familial support, and demographic and obstetric characteristics. Data were analyzed by descriptive statistics, the independent t-test, one-way ANOVA, Pearson correlation coefficients, and stepwise multiple regression using SPSS version 25.0. Results The mean score for maternal identity was 131.15 out of 160, and the mean scores for stress, depression, and spousal and familial support were 14.59 (out of 40), 6.82 (out of 30), and 109.04 (out of 132), respectively. Stress (r=–.38, p<.001), depression (r=–.37, p<.001), and spousal and familial support (r=.37, p<.001) were significantly correlated with maternal identity. In multiple regression analysis, stress (β=–0.27, p=.005) and spousal and familial support (β=0.23, p=.014) were found to be significant factors influencing maternal identity in pregnant women (F=14.19, p<.001). Conclusion It is necessary to develop effective strategies to mitigate stress and to encourage spousal and familial support in pregnant women. Such strategies could further enable pregnant women to enhance their maternal identity
Treatment response with potassium-competitive acid blockers based on clinical phenotypes of gastroesophageal reflux disease: A systematic literature review and meta-analysis
BACKGROUND/AIMS: Gastroesophageal reflux disease (GERD) is typically managed based on the clinical phenotype. We evaluated the efficacy and safety of potassium-competitive acid blockers (PCABs) in patients with various clinical GERD phenotypes.
METHODS: Core databases were searched for studies comparing PCABs and proton pump inhibitors (PPIs) in clinical GERD phenotypes of erosive reflux disease (ERD), non-erosive reflux disease (NERD), PPI-resistant GERD and night-time heartburn. Additional analysis was performed based on disease severity and drug dosage, and pooled efficacy was calculated.
RESULTS: In 9 randomized controlled trials (RCTs) evaluating the initial treatment of ERD, the risk ratio for healing with PCABs versus PPIs was 1.09 (95% CI, 1.04-1.13) at 2 weeks and 1.03 (95% CI, 1.00-1.07) at 8 weeks, respectively. PCABs exhibited a significant increase in both initial and sustained healing of ERD compared to PPIs in RCTs, driven particularly in severe ERD (Los Angeles grade C/D). In 3 NERD RCTs, PCAB was superior to placebo in proportion of days without heartburn. Observational studies on PPI-resistant symptomatic GERD reported symptom frequency improvement in 86.3% of patients, while 90.7% showed improvement in PPIresistant ERD across 5 observational studies. Two RCTs for night-time heartburn had different endpoints, limiting meta-analysis. Pronounced hypergastrinemia was observed in patients treated with PCABs.
CONCLUSIONS: Compared to PPIs, PCABs have superior efficacy and faster therapeutic effect in the initial and maintenance therapy of ERD, particularly severe ERD. While PCABs may be an alternative treatment option in NERD and PPI-resistant GERD, findings were inconclusive in patients with night-time heartburn
The determination of dark adaptation time using electroretinography in conscious Miniature Schnauzer dogs
The optimal dark adaptation time of electroretinograms (ERG's) performed on conscious dogs were determined using a commercially available ERG unit with a contact lens electrode and a built-in light source (LED-electrode). The ERG recordings were performed on nine healthy Miniature Schnauzer dogs. The bilateral ERG's at seven different dark adaptation times at an intensity of 2.5 cd·s/m2 was performed. Signal averaging (4 flashes of light stimuli) was adopted to reduce electrophysiologic noise. As the dark adaptation time increased, a significant increase in the mean a-wave amplitudes was observed in comparison to base-line levels up to 10 min (p < 0.05). Thereafter, no significant differences in amplitude occured over the dark adaptation time. Moreover, at this time the mean amplitude was 60.30 ± 18.47 µV. However, no significant changes were observed for the implicit times of the a-wave. The implicit times and amplitude of the b-wave increased significantly up to 20 min of dark adaptation (p < 0.05). Beyond this time, the mean b-wave amplitudes was 132.92 ± 17.79 µV. The results of the present study demonstrate that, the optimal dark adaptation time when performing ERG's, should be at least 20 min in conscious Miniature Schnauzer dogs
Recent Trend in the Incidence of Premalignant and Malignant Skin Lesions in Korea between 1991 and 2006
We evaluated the recent trend in the incidence of premalignant and malignant skin lesions between 1991 and 2006. Among 571,057 newly registered dermatology out-patients from our 8 affiliated university hospitals, 2,598 were diagnosed with a premalignant (899, 0.16%) or malignant skin lesions (1,699, 0.30%). Of 899 premalignant cases, 71.2% were actinic keratosis (AK), and 24.6% were Bowen's disease. Of 1,699 malignant cases, 46.2% were basal cell carcinoma, followed by squamous cell carcinoma (19.1%) and melanoma (7.1%). This 16-yr survey was divided equally into two time periods to compare the incidence of premalignant and malignant skin lesions at different time settings. Between 1991 and 1998, the incidence of cutaneous premalignancy was 0.10% which doubled during 1999-2006. For cutaneous malignancy, the incidence was 0.25% during 1991-1998 and 0.34% in 1999-2006. Incidence of AK among the new outpatients was 0.07% in 1991-1998 which staggered up to 0.15% in 1999-2006. These findings show an increase of both premalignant and malignant skin lesions, AK in particular in the dermatology outpatient-based incidence
Morning Glory Syndrome associated with Autosomal Dominant Alport Syndrome with a Heterozygous Mutation
Morning glory syndrome (MGS) is a rare congenital optic disc anomaly with a characteristic fundal finding with severe visual impairment. It may occur in association with various systemic manifestations, even though most of the reported cases were isolated. A 6-year-old male visited the nephrology clinic with a history of microscopic hematuria and at the age of 12 years, he was diagnosed thin glomerular basement membrane nephropathy by kidney biopsy. After the following years, the patient had progressive deterioration of visual acuity, and diagnosed as MGS. Whole Exome Sequencing of this patient and his mother revealed heterozygous COL4A4 mutations [c.81_86del (p.Ile29_Leu30del)]. It is more reasonable to consider MGS seen in this patient as a coincidental finding of autosomal dominant Alport syndrome. To our knowledge, this case represents the first case report of autosomal dominant Alport syndrome associated with MGS
A Case of Painful Hashimoto Thyroiditis that Mimicked Subacute Thyroiditis
Hashimoto thyroiditis (HT) is an autoimmune thyroid disorder that usually presents as a diffuse, nontender goiter, whereas subacute thyroiditis (SAT) is an uncommon disease that is characterized by tender thyroid enlargement, transient thyrotoxicosis, and an elevated erythrocyte sedimentation rate (ESR). Very rarely, patients with HT can present with painful, tender goiter or fever, a mimic of SAT. We report a case of painful HT in a 68-year-old woman who presented with pain and tenderness in a chronic goiter. Her ESR was definitely elevated and her thyroid laboratory tests suggested subclinical hypothyroidism of autoimmune origin. 99mTc pertechnetate uptake was markedly decreased. Fine needle aspiration biopsy revealed reactive and polymorphous lymphoid cells and occasional epithelial cells with Hürthle cell changes. Her clinical symptoms showed a dramatic response to glucocorticoid treatment. She became hypothyroid finally and is now on levothyroxine therapy
Effect of chitinase- 3- like protein 1 on glucose metabolism: In vitro skeletal muscle and human genetic association study
We investigated the effect of chitinase- 3- like protein 1 (CHI3L1) on glucose metabolism and its underlying mechanisms in skeletal muscle cells, and evaluated whether the observed effects are relevant in humans. CHI3L1 was associated with increased glucose uptake in skeletal muscles in an AMP- activated protein kinase (AMPK)- dependent manner, and with increased intracellular calcium levels via PAR2. The improvement in glucose metabolism observed in an intraperitoneal glucose tolerance test on male C57BL/6J mice supported this association. Inhibition of the CaMKK was associated with suppression of CHI3L1- mediated glucose uptake. Additionally, CHI3L1 was found to influence glucose uptake through the PI3K/AKT pathway. Results suggested that CHI3L1 stimulated the phosphorylation of AS160 and p38 MAPK downstream of AMPK and AKT, and the resultant GLUT4 translocation. In primary myoblast cells, stimulation of AMPK and AKT was observed in response to CHI3L1, underscoring the biological relevance of CHI3L1. CHI3L1 levels were elevated in cells under conditions that mimic exercise in vitro and in exercised mice in vivo, indicating that CHI3L1 is secreted during muscle contraction. Finally, similar associations between CHI3L1 and metabolic parameters were observed in humans alongside genotype associations between CHI3L1 and diabetes at the population level. CHI3L1 may be a potential therapeutic target for the treatment of diabetes.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/162777/2/fsb220907.pdfhttp://deepblue.lib.umich.edu/bitstream/2027.42/162777/1/fsb220907_am.pd
First-time comparison between NO2 vertical columns from GEMS and Pandora measurements
The Geostationary Environmental Monitoring Spectrometer (GEMS) is a UV–visible spectrometer onboard the GEO-KOMPSAT-2B satellite launched into geostationary orbit in February 2020. To evaluate GEMS NO2 column data, comparison was carried out using NO2 vertical column density (VCD) measured using direct-sunlight observations by the Pandora spectrometer system at four sites in Seosan, South Korea, during November 2020 to January 2021. Correlation coefficients between GEMS and Pandora NO2 data at four sites ranged from 0.35 to 0.48, with root mean square errors (RMSEs) from 4.7 × 1015 molec. cm-2 to 5.5 × 1015 molec. cm-2 for cloud fraction (CF) < 0.7. Higher correlation coefficients of 0.62–0.78 with lower RMSEs from 3.3 × 1015 molec. cm-2 to 4.3 × 1015 molec. cm-2 were found with CF < 0.3, indicating the higher sensitivity of GEMS to atmospheric NO2 in less-cloudy conditions. Overall, GEMS NO2 column data tend to be lower than those of Pandora due to differences in representative spatial coverage, with a large negative bias under high-CF conditions. With correction for horizontal representativeness in Pandora measurement coverage, the correlation coefficients range from 0.69 to 0.81 with RMSEs from 3.2 × 1015 molec. cm-2 to 4.9 × 1015 molec. cm-2 were achieved for CF < 0.3, showing the better correlation with the correction than that without the correction.</p
First-time comparison between NO2 vertical columns from Geostationary Environmental Monitoring Spectrometer (GEMS) and Pandora measurements
The Geostationary Environmental Monitoring Spectrometer (GEMS) is a UV-visible (UV-Vis) spectrometer on board the GEO-KOMPSAT-2B (Geostationary Korea Multi-Purpose Satellite 2B) satellite launched into a geostationary orbit in February 2020. To evaluate the GEMS NO2 total column data, a comparison was carried out using the NO2 vertical column density (VCD) that measured direct sunlight using the Pandora spectrometer system at four sites in Seosan, South Korea, from November 2020 to January 2021. Correlation coefficients between GEMS and Pandora NO2 data at four sites ranged from 0.35 to 0.48, with root mean square errors (RMSEs) from 4.7×1015 to 5.5×1015 molec. cm−2 for a cloud fraction (CF) <0.7. Higher correlation coefficients of 0.62–0.78 with lower RMSEs from 3.3×1015 to 5.0×1015 molec. cm−2 were found with CF <0.3, indicating the higher sensitivity of GEMS to atmospheric NO2 in less cloudy conditions. Overall, the GEMS NO2 total column data tended to be lower than the Pandora data, owing to differences in the representative spatial coverage, with a large negative bias under high CF conditions. With a correction for horizontal representativeness in the Pandora measurement coverage, correlation coefficients ranging from 0.69 to 0.81, with RMSEs from 3.2×1015 to 4.9×1015 molec. cm−2, were achieved for CF <0.3, showing a better correlation with the correction than without the correction.</p
- …