20 research outputs found

    CT colonography polyp matching: differences between experienced readers

    Get PDF
    The purpose of this study was to investigate if experienced readers differ when matching polyps shown by both CT colonography (CTC) and optical colonoscopy (OC) and to explore the reasons for discrepancy. Twenty-eight CTC cases with corresponding OC were presented to eight experienced CTC readers. Cases represented a broad spectrum of findings, not completely fulfilling typical matching criteria. In 21 cases there was a single polyp on CTC and OC; in seven there were multiple polyps. Agreement between readers for matching was analyzed. For the 21 single-polyp cases, the number of correct matches per reader varied from 13 to 19. Almost complete agreement between readers was observed in 15 cases (71%), but substantial discrepancy was found for the remaining six (29%) probably due to large perceived differences in polyp size between CT and OC. Readers were able to match between 27 (71%) and 35 (92%) of the 38 CTC detected polyps in the seven cases with multiple polyps. Experienced CTC readers agree to a considerable extent when matching polyps between CTC and subsequent OC, but non-negligible disagreement exist

    Image quality and patient acceptance of four regimens with different amounts of mild laxatives for CT colonography

    No full text
    OBJECTIVE: The purpose of our study was to prospectively evaluate image quality and patient acceptance of CT colonography (CTC) with fecal tagging using different levels of catharsis. SUBJECTS AND METHODS: Forty consecutive increased-risk patients were randomized. Group 1 received orally 20 mg of bisacodyl, group 2 received 30 mg of bisacodyl, group 3 received 20 mg of bisacodyl and 8.2 g of magnesium citrate, and group 4 received 30 mg of bisacodyl and 16.4 g of magnesium citrate. All patients used a 2-day low-fiber diet and received diatrizoate meglumine and barium for fecal tagging. One reviewer blindly scored subjective image quality (fecal tagging, amount of residual feces [liquid or solid], luminal distention, and image readability) on a 5- to 6-point scale using a 2D review technique. The mean and SD of attenuation of tagging were measured as well as the relative SD as a measure of homogeneity. Furthermore, patient acceptance (burden related to diarrhea, abdominal pain, flatulence, and overall burden) was evaluated. Ordinal regression, generalized estimating equations, and parametric and nonparametric tests were used for analysis. RESULTS: Image readability was evaluated as good or excellent in all examinations except one in group 2 (nondiagnostic) and two in group 3 (moderate). Group 2 contained more feces than group 4 (p = 0.04). With regard to mean attenuation and homogeneity of tagging, no significant differences were observed between groups. Group 4 experienced more severe diarrhea than groups 1 and 2 and higher overall burden than groups 1 and 3 (p < 0.042). CONCLUSION: The mildest preparation with 20 mg of bisacodyl provided good image quality of CTC images. Increasing the amount of laxatives did not improve image quality or tagging characteristics but was associated with a lower patient acceptanc

    Effective radiation doses in CT colonography: results of an inventory among research institutions

    No full text
    The purpose of this study was to estimate the effective dose that is currently used in CT colonography using scan parameters that were collected for this purpose, and to investigate trends in time. PubMed was systematically searched from 1996 until January 2004 for studies investigating CT colonography. Research institutions were contacted and asked for their current scan protocol. Thirty-six institutions published 74 studies. Twenty-eight of the 36 institutions provided their current protocol. The median effective dose in 2004 was 5.1 mSv (range 1.2-11.7 mSv) per position. Most institutions (93%) scan in both the supine and prone positions. The median mAs value was 67 mAs (range 20-200), median collimation was 2.5 mm (range 0.75-5). From 1996 until 2004 a significant decrease in mAs and collimation (P=0.006, P <0.0001, respectively) was observed, while institutions that used a multislice scanner increased (P <0.0001). The effective dose remained constant (P=0.76). In 2004 the median effective dose for a complete CT colonography was 10.2 mSv. Despite the increasing use of multislice scanners, which are slightly less dose-efficient, the median effective dose remained approximately constant between 1996 and 2004. This is mainly caused by the use of lower mAs setting

    CT colonography with limited bowel preparation: prospective assessment of patient experience and preference in comparison to optical colonoscopy with cathartic bowel preparation

    Get PDF
    The purpose of this study was to prospectively compare participant experience and preference of limited preparation computed tomography colonography (CTC) with full-preparation colonoscopy in a consecutive series of patients at increased risk of colorectal cancer. CTC preparation comprised 180 ml diatrizoate meglumine, 80 ml barium and 30 mg bisacodyl. For the colonoscopy preparation 4 l of polyethylene glycol solution was used. Participants' experience and preference were compared using the Wilcoxon signed rank test and the chi-squared test, respectively. Associations between preference and experience parameters for the 173 participants were determined by logistic regression. Diarrhoea occurred in 94% of participants during CTC preparation. This side effect was perceived as severely or extremely burdensome by 29%. Nonetheless, the total burden was significantly lower for the CTC preparation than for colonoscopy (9% rated the CTC preparation as severely or extremely burdensome compared with 59% for colonoscopy; p <0.001). Participants experienced significantly more pain, discomfort and total burden with the colonoscopy procedure than with CTC (p <0.001). After 5 weeks, 69% preferred CTC, 8% were indifferent and 23% preferred colonoscopy (p <0.001). A burdensome colonoscopy preparation and pain at colonoscopy were associated with CTC preference (p <0.04). In conclusion, participants' experience and preference were rated in favour of CTC with limited bowel preparation compared with full-preparation colonoscop

    Does a computer-aided detection algorithm in a second read paradigm enhance the performance of experienced computed tomography colonography readers in a population of increased risk?

    Get PDF
    We prospectively determined whether computer-aided detection (CAD) could improve the performance characteristics of computed tomography colonography (CTC) in a population of increased risk for colorectal cancer. Therefore, we included 170 consecutive patients that underwent both CTC and colonoscopy. All findings a parts per thousand yen6 mm were evaluated at colonoscopy by segmental unblinding. We determined per-patient sensitivity and specificity for polyps a parts per thousand yen6 mm and a parts per thousand yen10 mm without and with computer-aided detection (CAD). The McNemar test was used for comparison the results without and with CAD. Unblinded colonoscopy detected 50 patients with lesions a parts per thousand yen6 mm and 25 patients with lesions a parts per thousand yen10 mm. Sensitivity of CTC without CAD for these size categories was 80% (40/50, 95% CI: 69-81%) and 64% (16/25, 95% CI: 45-83%), respectively. CTC with CAD detected one additional patient with a lesion a parts per thousand yen6 mm and two with a lesion a parts per thousand yen10 mm, resulting in a sensitivity of 82% (41/50, 95% CI: 71-93%) (p = 0.50) and 72% (18/25, 95% CI: 54-90%) (p = 1.0), respectively. Specificity without CAD for polyps a parts per thousand yen6 mm and a parts per thousand yen10 mm was 84% (101/120, 95% CI: 78-91%) and 94% (136/145, 95% CI: 90-98%), respectively. With CAD, the specificity remained (nearly) unchanged: 83% (99/120, 95% CI: 76-89%) and 94% (136/145, 95% CI: 90-98%), respectively. Thus, although CTC with CAD detected a few more patients than CTC without CAD, it had no statistically significant positive influence on CTC performanc

    Acute Appendicitis on Abdominal MR Images: Training Readers to Improve Diagnostic Accuracy

    No full text
    Purpose: To determine if training with direct feedback helps to improve the diagnostic performance of inexperienced readers in the detection of appendicitis on magnetic resonance (MR) images. Materials and Methods: The institutional review board approved this retrospective study and waived the requirement for informed consent. Nine radiologists and eight residents without experience in evaluating MR images for acute abdominal conditions evaluated a training set of images from 100 MR imaging examinations of patients suspected of having appendicitis and received direct feedback after each evaluation. An expert panel made a diagnosis of appendicitis in 45 patients and an alternative diagnosis in 55 patients on the basis of histopathologic examination and follow-up. Readers recorded two diagnoses: the first after viewing images from conventional MR sequences (half-Fourier rapid acquisition with relaxation enhancement and true fast imaging with steady-state precession) and the second after viewing diffusion-weighted (DW) MR images. Reader sensitivity and specificity were calculated per set of 25 cases. Results: The average reader sensitivity for detecting appendicitis improved significantly after training (0.82 vs 0.92, P = .003); the average specificity improved nonsignificantly (0.82 vs 0.88, P = .10). Sensitivity for radiologists increased from 0.81 in the first set of 25 cases to 0.91 in the last set, and specificity improved from 0.82 to 0.85. For residents, sensitivity increased from 0.82 to 0.94, and specificity increased from 0.82 to 0.91. Sensitivity improved from 0.80 to 0.87 (P <.001) in all readings combined when DW images were read in addition to conventional MR images. Conclusion: Diagnostic accuracy of inexperienced readers in the evaluation of abdominal MR images for acute appendicitis improved after training with direct feedback, and the addition of DW images improved reader sensitivity. (c) RSNA, 201

    Acute appendicitis on abdominal MR images: training readers to improve diagnostic accuracy

    No full text
    PURPOSE: To determine if training with direct feedback helps to improve the diagnostic performance of inexperienced readers in the detection of appendicitis on magnetic resonance (MR) images. MATERIALS AND METHODS: The institutional review board approved this retrospective study and waived the requirement for informed consent. Nine radiologists and eight residents without experience in evaluating MR images for acute abdominal conditions evaluated a training set of images from 100 MR imaging examinations of patients suspected of having appendicitis and received direct feedback after each evaluation. An expert panel made a diagnosis of appendicitis in 45 patients and an alternative diagnosis in 55 patients on the basis of histopathologic examination and follow-up. Readers recorded two diagnoses: the first after viewing images from conventional MR sequences (half-Fourier rapid acquisition with relaxation enhancement and true fast imaging with steady-state precession) and the second after viewing diffusion-weighted (DW) MR images. Reader sensitivity and specificity were calculated per set of 25 cases. RESULTS: The average reader sensitivity for detecting appendicitis improved significantly after training (0.82 vs 0.92, P = .003); the average specificity improved nonsignificantly (0.82 vs 0.88, P = .10). Sensitivity for radiologists increased from 0.81 in the first set of 25 cases to 0.91 in the last set, and specificity improved from 0.82 to 0.85. For residents, sensitivity increased from 0.82 to 0.94, and specificity increased from 0.82 to 0.91. Sensitivity improved from 0.80 to 0.87 (P < .001) in all readings combined when DW images were read in addition to conventional MR images. CONCLUSION: Diagnostic accuracy of inexperienced readers in the evaluation of abdominal MR images for acute appendicitis improved after training with direct feedback, and the addition of DW images improved reader sensitivity

    MRI features associated with acute appendicitis

    No full text
    To identify MRI features associated with appendicitis. Features expected to be associated with appendicitis were recorded in consensus by two expert radiologists on 223 abdominal MRIs in patients with suspected appendicitis. Nine MRI features were studied: appendix diameter >7 mm, appendicolith, peri-appendiceal fat infiltration, peri-appendiceal fluid, absence of gas in the appendix, appendiceal wall destruction, restricted diffusion of the appendiceal wall, lumen or focal fluid collections. Appendicitis was assigned as the final diagnosis in 117/223 patients. Associations between imaging features and appendicitis were evaluated with logistic regression analysis. All investigated features were significantly associated with appendicitis in univariate analysis. Combinations of two and three features were associated with a probability of appendicitis of 88 % and 92 %, respectively. In patients without any of the nine features, appendicitis was present in 2 % of cases. After multivariate analysis, only an appendix diameter >7 mm, peri-appendiceal fat infiltration and restricted diffusion of the appendiceal wall were significantly associated with appendicitis. The probability of appendicitis was 96 % in their presence and 2 % in their absence. An appendix diameter >7 mm, peri-appendiceal fat infiltration and restricted diffusion of the appendiceal wall have the strongest association with appendicitis on MRI. • An enlarged appendix, fat infiltration and restricted diffusion are associated with appendicitis. • One such feature on MRI gives an 88 % probability of appendicitis. • Two features in combination give a probability of appendicitis of 94 %. • Combinations of three features give a probability of appendicitis of 96 %. • The absence of these features almost rules out appendicitis (2 %
    corecore