29 research outputs found

    CT colonography polyp matching: differences between experienced readers

    Get PDF
    The purpose of this study was to investigate if experienced readers differ when matching polyps shown by both CT colonography (CTC) and optical colonoscopy (OC) and to explore the reasons for discrepancy. Twenty-eight CTC cases with corresponding OC were presented to eight experienced CTC readers. Cases represented a broad spectrum of findings, not completely fulfilling typical matching criteria. In 21 cases there was a single polyp on CTC and OC; in seven there were multiple polyps. Agreement between readers for matching was analyzed. For the 21 single-polyp cases, the number of correct matches per reader varied from 13 to 19. Almost complete agreement between readers was observed in 15 cases (71%), but substantial discrepancy was found for the remaining six (29%) probably due to large perceived differences in polyp size between CT and OC. Readers were able to match between 27 (71%) and 35 (92%) of the 38 CTC detected polyps in the seven cases with multiple polyps. Experienced CTC readers agree to a considerable extent when matching polyps between CTC and subsequent OC, but non-negligible disagreement exist

    Polyp measurement based on CT colonography and colonoscopy: variability and systematic differences

    Get PDF
    To assess the variability and systematic differences in polyp measurements on optical colonoscopy and CT colonography. Gastroenterologists measured 51 polyps by visual estimation, forceps comparison and linear probe. CT colonography observers randomly assessed polyp size two-dimensionally (abdominal and intermediate window) and three-dimensionally (manually and semi-automatically). Linear mixed models were used to assess the variability and systematic differences between CT colonography and optical colonoscopy techniques. The variability of forceps and linear probe measurements was comparable and both showed less variability than measurement by visual assessment. Measurements by linear probe were 0.7 mm smaller than measurements by visual assessment or by forceps. The variability of all CT colonography techniques was lower than for measurements by forceps or visual assessment and sometimes lower (only 2D intermediate window and manual 3D) compared with measurements by linear probe. All CT colonography measurements judged polyps to be larger than optical colonoscopy, with differences ranging from 0.7 to 2.3 mm. A linear probe does not reduce the measurement variability of endoscopists compared with the forceps. Measurement differences between observers on CT colonography were usually smaller than at optical colonoscopy. Polyps appeared larger when using various CT colonography techniques than when measured during optical colonoscop

    Feasibility study of computed tomography colonography using limited bowel preparation at normal and low-dose levels study

    Get PDF
    The purpose was to evaluate low-dose CT colonography without cathartic cleansing in terms of image quality, polyp visualization and patient acceptance. Sixty-one patients scheduled for colonoscopy started a low-fiber diet, lactulose and amidotrizoic-acid for fecal tagging 2 days prior to the CT scan (standard dose, 5.8–8.2 mSv). The original raw data of 51 patients were modified and reconstructed at simulated 2.3 and 0.7 mSv levels. Two observers evaluated the standard dose scan regarding image quality and polyps. A third evaluated the presence of polyps at all three mSv levels in a blinded prospective way. All observers were blinded to the reference standard: colonoscopy. At three times patients were given questionnaires relating to their experiences and preference. Image quality was sufficient in all patients, but significantly lower in the cecum, sigmoid and rectum. The two observers correctly identified respectively 10/15 (67%) and 9/15 (60%) polyps ≥10 mm, with 5 and 8 false-positive lesions (standard dose scan). Dose reduction down to 0.7 mSv was not associated with significant changes in diagnostic value (polyps ≥10 mm). Eighty percent of patients preferred CT colonography and 13% preferred colonoscopy (P<0.001). CT colonography without cleansing is preferred to colonoscopy and shows sufficient image quality and moderate sensitivity, without impaired diagnostic value at dose-levels as low as 0.7 mSv

    Influence of Tagged Fecal Material on Detectability of Colorectal Polyps at CT: Phantom Study

    No full text
    OBJECTIVE. The purpose of this study was to determine the influence of tagged material on the minimal radiation dose needed to detect colorectal polyps at CT. MATERIALS AND METHODS. The study was conducted in two phases. In the first, three experienced observers determined the visibility of sessile polyps (6 mm) at five contrast levels (300, 490, 790, and 1,040 HU and air) and five tube charge levels (10, 14, 20, 28, and 40 mAs) in an anthropomorphic phantom. Each polyp was present in one of eight possible locations. The mean tube charge threshold for 90% correct responses was determined for each contrast level. Blinded observers performed independent 2D readings. In the second phase of the study, three 150-cm virtual colons were evaluated at two contrast levels (300 and 480 HU) and at five tube charge levels between 20 and 80 mAs. The three colons contained 18 randomly located polyps. The mean tube charge threshold for 90% sensitivity was determined for each contrast level. RESULTS. In the first phase of the study, the estimated tube charge thresholds for 300, 480, and 790 HU were 24.0, 16.3, and 6.2 mAs. At 1,040 HU and in air, all polyps were detected at the lowest tube charge setting (10 mAs). In the second phase, the tube charge thresholds for 90% sensitivity at 300 and 480 HU were 70 and 35 mAs, respectively. CONCLUSION. If polyps are covered by fecal material, a considerably higher tube charge setting is needed for adequate visualization than is needed for polyps in a completely cleansed colon, especially when the density of the tagged residue is lo

    Dynamic contrast-enhanced MRI of the bowel wall for assessment of disease activity in Crohn's disease

    No full text
    OBJECTIVE: The purpose of this study was to evaluate the role of contrast-enhanced dynamic MRI in predicting the disease activity of Crohn's disease. MATERIALS AND METHODS: Forty-eight patients in two hospitals who had clinically suspected exacerbation of Crohn's disease were included in this study. In three levels of thickened small-bowel wall, axial dynamic T1-weighted sequences were performed every 4-6 sec for a total duration of 2-3 min after contrast administration; static T1-weighted turbo spin-echo sequences were acquired both before and after contrast administration. The slope of enhancement, enhancement ratio, time to enhancement, enhancement time, and thickness of the small-bowel wall were determined. These MRI results were compared with overall clinical grade, Crohn's disease activity index (CDAI), and Van Hees activity index. Clinical grade was based on clinical information, physical findings, laboratory studies, endoscopy, surgery, and other imaging studies. Spearman's correlation coefficient and p values were determined per hospital. Fisher's z-transformation was applied before pooling the correlation coefficients from both hospitals. RESULTS: The enhancement ratio based on the static series showed significant correlation with the clinical grade (r = 0.29, p = 0.045), CDAI (r =0.31, p = 0.033), and Van Hees activity index (r = 0.36, p = 0.016). The enhancement ratio based on the dynamic series correlated significantly with the CDAI (r = 0.38, p = 0.016). Wall thickness correlated significantly with clinical grade (r = 0.47, p = 0.003) and Van Hees activity index (r = 0.41, p = 0.007). CONCLUSION: These data suggest that the enhancement ratio of bowel wall after IV administration of gadodiamide and bowel wall thickness are weak to moderate indicators of the severity of Crohn's diseas

    Magnetic resonance imaging compared with ileocolonoscopy in evaluating disease severity in Crohn's disease

    No full text
    BACKGROUND & AIMS: Abdominal magnetic resonance imaging (MRI) has shown promising results in the detection of Crohn's disease (CD)-related lesions. The purpose of this study was to assess the value of MRI in measuring disease activity in CD patients in comparison with ileocolonoscopy. METHODS: Thirty-one patients undergoing ileocolonoscopy because of suspicion of relapsing CD underwent MRI with water as intraluminal contrast medium. At endoscopy, disease severity was graded (4-point scale), and Crohn's Disease Endoscopic Index of Severity (CDEIS) was determined. Two radiologists independently interpreted the MRI scans. Radiologic grading (4-point scale) was compared with endoscopic grading of disease severity and CDEIS (overall, for all segments). Wall thickness and enhancement were compared with CDEIS. Patient experience and preference were determined. RESULTS: In, respectively, 14 and 14 patients (radiologist 1) and 16 and 11 patients (radiologist 2) an exact match or 1 level of difference in grading was scored with the endoscopist. Correlation between severity rated at MRI and CDEIS was moderate to strong with r = 0.61 (P < .001) for observer 1 and r = 0.63 (P < .001) for observer 2. Per segment, best correlation was seen in the terminal ileum (r = 0.63; P < .001, for both observers). Wall thickness correlated moderately to strongly with CDEIS (r = 0.57, P < .001 and r = 0.50, P < .001 for observers 1 and 2), whereas enhancement correlated weakly to moderately (r = 0.45, P < .001 and r = 0.42, P < .001). Patients experienced more pain during endoscopy, and all patients except 2 preferred MRI to endoscopy. CONCLUSION: MRI can correctly identify disease severity in patients with CD and is a patient-friendly alternative to ileocolonoscop

    Image quality and patient acceptance of four regimens with different amounts of mild laxatives for CT colonography

    No full text
    OBJECTIVE: The purpose of our study was to prospectively evaluate image quality and patient acceptance of CT colonography (CTC) with fecal tagging using different levels of catharsis. SUBJECTS AND METHODS: Forty consecutive increased-risk patients were randomized. Group 1 received orally 20 mg of bisacodyl, group 2 received 30 mg of bisacodyl, group 3 received 20 mg of bisacodyl and 8.2 g of magnesium citrate, and group 4 received 30 mg of bisacodyl and 16.4 g of magnesium citrate. All patients used a 2-day low-fiber diet and received diatrizoate meglumine and barium for fecal tagging. One reviewer blindly scored subjective image quality (fecal tagging, amount of residual feces [liquid or solid], luminal distention, and image readability) on a 5- to 6-point scale using a 2D review technique. The mean and SD of attenuation of tagging were measured as well as the relative SD as a measure of homogeneity. Furthermore, patient acceptance (burden related to diarrhea, abdominal pain, flatulence, and overall burden) was evaluated. Ordinal regression, generalized estimating equations, and parametric and nonparametric tests were used for analysis. RESULTS: Image readability was evaluated as good or excellent in all examinations except one in group 2 (nondiagnostic) and two in group 3 (moderate). Group 2 contained more feces than group 4 (p = 0.04). With regard to mean attenuation and homogeneity of tagging, no significant differences were observed between groups. Group 4 experienced more severe diarrhea than groups 1 and 2 and higher overall burden than groups 1 and 3 (p < 0.042). CONCLUSION: The mildest preparation with 20 mg of bisacodyl provided good image quality of CTC images. Increasing the amount of laxatives did not improve image quality or tagging characteristics but was associated with a lower patient acceptanc

    Computed Cleansing for CT Colonography Using a Three-Material Transition Model

    No full text
    Virtual colonoscopy is a non-invasive technique for the detection of polyps. Currently, a clean colon is required; as without cleansing the colonic wall cannot be segmented. Enhanced bowel preparation schemes opacify intraluminal remains to enable colon segmentation. Computed cleansing (as opposed to physical cleansing of the bowels) allows removal of tagged intraluminal remains. This paper describes a model that allows proper classification of transitions between three materials: gas, tissue and tagged intraluminal remains. Using a twomaterial transition model leads to polyps that may be missed if located at these junctions or artefacts that may be misjudged as polyps. The computed cleansing effectively detects and removes the remains from the data. Inspection of the &apos;clean &apos; wall is possible using common surface visualization techniques. 1

    CT colonography and colonoscopy: Assessment of patient preference in a 5-week follow-up study

    No full text
    PURPOSE: To prospectively evaluate short- and midterm patient preference of computed tomographic (CT) colonography relative to colonoscopy in patients at increased risk for colorectal cancer and to elucidate determinants of preference. MATERIALS AND METHODS: Consecutive patients at increased risk for colorectal cancer underwent CT colonography prior to scheduled colonoscopy. Patient experience and preference were assessed both directly after the examinations and 5 weeks after the examinations. Differences in pain, embarrassment, discomfort, and preference were assessed with the Wilcoxon signed rank sum test or a binomial test. Potential determinants of preference were investigated with logistic regression analyses. RESULTS: Data for 249 patients were included. Fewer patients experienced severe or extreme pain during CT colonography (seven [3%] of 245) than during colonoscopy (81 [34%] of 241) (P <.001). Directly after both examinations, 168 (71%) of 236 patients preferred CT colonography; 5 weeks later, 141 (61%) of 233 patients preferred CT colonography (P <.001). Initially, a painful colonoscopy examination (odds ratio, 0.17; 95% confidence interval [Cl]: 0.08, 0.38) was a determinant of CT colonography preference. Similarly, a painful (odds ratio, 3.70; 95% Cl: 1.54, 8.92) or an embarrassing (odds ratio, 4.46; 95% Cl: 1.18, 16.88) CT colonography examination was a determinant of colonoscopy preference. After 5 weeks, the presence of polyps emerged as a determinant of colonoscopy preference (odds ratio, 1.94; 95% Cl: 1.02, 3.70), while the role of experiences waned. CONCLUSION: Patients preferred CT colonography to colonoscopy; however, this preference decreased in time, while outcome considerations gradually replaced temporary experiences of inconvenience. (C) RSNA, 200
    corecore