22 research outputs found

    Effectiveness of a home-based re-injury prevention program on motor control, return to sport and recurrence rates after anterior cruciate ligament reconstruction: study protocol for a multicenter, single-blind, randomized controlled trial (PReP)

    Get PDF
    Background: Although anterior cruciate ligament (ACL) tear-prevention programs may be effective in the (secondary) prevention of a subsequent ACL injury, little is known, yet, on their effectiveness and feasibility. This study assesses the effects and implementation capacity of a secondary preventive motor-control training (the Stop-X program) after ACL reconstruction. Methods and design: A multicenter, single-blind, randomized controlled, prospective, superiority, two-arm design is adopted. Subsequent patients (18–35 years) with primary arthroscopic unilateral ACL reconstruction with autologous hamstring graft are enrolled. Postoperative guideline rehabilitation plus Classic follow-up treatment and guideline rehabilitation plus the Stop-X intervention will be compared. The onset of the Stop-X program as part of the postoperative follow-up treatment is individualized and function based. The participants must be released for the training components. The endpoint is the unrestricted return to sport (RTS) decision. Before (where applicable) reconstruction and after the clearance for the intervention (aimed at 4–8 months post surgery) until the unrestricted RTS decision (but at least until 12 months post surgery), all outcomes will be assessed once a month. Each participant is consequently measured at least five times to a maximum of 12 times. Twelve, 18 and 24 months after the surgery, follow-up-measurements and recurrence monitoring will follow. The primary outcome assessement (normalized knee-separation distance at the Drop Jump Screening Test (DJST)) is followed by the functional secondary outcomes assessements. The latter consist of quality assessments during simple (combined) balance side, balance front and single-leg hops for distance. All hop/jump tests are self-administered and filmed from the frontal view (3-m distance). All videos are transferred using safe big content transfer and subsequently (and blinded) expertly video-rated. Secondary outcomes are questionnaires on patient-reported knee function, kinesiophobia, RTS after ACL injury and training/therapy volume (frequency – intensity – type and time). All questionnaires are completed online using the participants’ pseudonym only. Group allocation is executed randomly. The training intervention (Stop-X arm) consists of self-administered home-based exercises. The exercises are step-wise graduated and follow wound healing and functional restoration criteria. The training frequency for both arms is scheduled to be three times per week, each time for a 30 min duration. The program follows current (secondary) prevention guidelines. Repeated measurements gain-score analyses using analyses of (co-)variance are performed for all outcomes. Trial registration: German Clinical Trials Register, identification number DRKS00015313. Registered on 1 October 2018

    Visualization of complicated fractures by 3D-printed models for teaching and surgery: hands-on transitional fractures of the ankle

    No full text
    Aims: Understanding the orientation of fracture lines and mechanisms is the essential key to sufficient surgical therapy, but there is still a lack of visualization and teaching methods in traumatology and fracture theory. 3D-printed models offer easy approach to those fractures. This paper explains the use of the teaching possibility with 3-dimensional models of transitional fractures of the ankle. Methods and results: For generating 3D printable models, already obtained CT data were used and segmented into its different tissues, especially parts concerning the fracture. After the segmentation process, the models were produced with FFF (fused filament fabrication) printing technology. The fracture models then were used for hands-on teaching courses in AO course (Arbeitsgemeinschaft fĂĽr Osteosynthesefragen) of pediatric traumatology in 2020 in Frankfurt. In the course fracture anatomy with typical fracture lines, approaches, and screw placement could be shown, discussed and practiced. Conclusion: The study shows the use of 3D-printed teaching models and helps to understand complicated fractures, in this case, transitional fractures of the ankle. The teaching method can be adapted to numerous other use cases

    Primary or revision arthroplasty with an integrated acetabular cup—MUTARS® RS cup system

    No full text
    Introduction: The aim of this article is to show a new concept of indication and application of the MUTARS® RS Cup System in primary and revision hip arthroplasty. This integrated system is applicable for different acetabular cup replacements in patients with acetabular fractures or instable defects, as well as periprosthetic acetabular fractures. The MUTARS® RS Cup System is a cementless revision cup for insertion into the acetabulum with an integrated polyethylene cup, which fits to a regular or bipolar head. This system replaces the conventional approach for acetabular revision with a Burch-Schneider ring, in which a normal polyethylene cup is cemented. This interface with its complications is avoided with this system of a titanium revision cup with integrated polyethylene cup. Steps of preoperative planning and the intraoperative implementation will be highlighted in this article. Material and methods: This system was applied in 49 patients with 52 MUTARS® RS Cup Implantations in 30 males, 22 females, with an average age of 76,1 years (36,9–94,4 years). Results and discussion: The system shows a good operative feasibility, as well as a reliable handling and safe method for stable treatment of non-reconstructable acetabular fractures or acetabular incongruencies and instabilities

    Sterilization of PLA after Fused Filament Fabrication 3D Printing: Evaluation on Inherent Sterility and the Impossibility of Autoclavation

    No full text
    Three-dimensional printing, especially fused filament fabrication (FFF), offers great possibilities in (bio-)medical applications, but a major downside is the difficulty in sterilizing the produced parts. This study evaluates the questions of whether autoclaving is a possible solution for FFF-printed parts and if the printer itself could be seen as an inherent sterilization method. In a first step, an investigation was performed on the deformation of cylindrically shaped test parts after running them through the autoclaving process. Furthermore, the inherent sterility possibilities of the printing process itself were evaluated using culture medium sterility tests. It could be shown that, depending on the needed accuracy, parts down to a diameter of 5–10 mm can still be sterilized using autoclaving, while finer parts suffer from major deformations. For these, inherent sterilization of the printer itself is an option. During the printing process, over a certain contact time, heat at a higher level than that used in autoclaving is applied to the printed parts. The contact time, depending on the printing parameters, is calculated using the established formula. The results show that for stronger parts, autoclaving offers a cheap and good option for sterilization after FFF-printing. However, the inherent sterility possibilities of the printer itself can be considered, especially when printing with small layer heights for finer parts

    Secondary angio-embolization after emergent pelvic stabilization and pelvic packing is a safe option for patients with persistent hemorrhage from unstable pelvic ring injuries

    No full text
    Introduction: In patients with severe pelvic ring injuries, exsanguination still is the leading cause of death in the early post-injury phase. While mechanical pelvic ring stabilization and pre-peritoneal pelvic packing are mainly addressing venous bleeding, angio-embolization aims to control arterial bleeding. The goal of the present study was to evaluate the rate of postoperative angio-embolization after mechanical pelvic ring injury stabilization and pre-peritoneal pelvic packing. Bleeding sources detected in the angiography and the patient's outcome were investigated. Patients and Methods: Retrospective observational cohort study at a single academic level I trauma center, reviewing all patients with pelvic ring injuries admitted from 01/2010 to 12/2019. Patients with emergent mechanical pelvic ring stabilization (supraacetabular external fixator and/or pelvic C-clamp) and direct pre-peritoneal pelvic packing were further analyzed. Patients that underwent postoperative angio-embolization were compared with those that did not. All postoperative angio-embolizations were evaluated with regards to bleeding sources and type of embolization. Results: During the study period, a total of 39 patients required immediate mechanical pelvic stabilization and direct pre-peritoneal pelvic packing. Of these, 12 patients (30.8%) underwent a postoperative angio-embolization. The following vessels were identified as bleeding sources: superior gluteal artery (n = 6), obturator artery (n = 2), internal pudendal artery (n = 2), unnamed branches of the internal iliac artery (n = 3). A selective embolization was successful in 11 patients; in 1 patient, an unilateral complete occlusion of the internal iliac artery was performed to control the bleeding. Mean time from hospital admission to the surgical procedure was 52.8 ± 14.7 min and the mean time from admission to angio-embolization was 189.1 ± 55.5 min. The in-hospital mortality rate of patients with angio-embolization was 25.0% (n = 3). Of these, 2 patients died due to multiple organ failure and 1 patient due to severe head injury. Conclusion: Secondary angio-embolization after external pelvic fixation and pre-peritoneal pelvic packing was effective in controlling ongoing bleeding. The most frequently detected bleeding vessel was the superior gluteal artery, which is difficult to surgically address, further highlighting the importance of angio-embolization in the management algorithm

    The effect of written standardized feedback on the structure and quality of surgical lectures: A prospective cohort study

    No full text
    Abstract Background Lectures remain an important teaching method to present and structure knowledge to many students concurrently. Adequate measures are necessary to maintain the quality of the lectures. The aim of this study was to determine the impact on the lecture quality using written structured feedback and to compare the ratings of surgical lectures between students and surgical peers. Methods Prospective analysis of two consecutive surgical lecture series for undergraduate students at Goethe-University Medical School was performed before and after evaluation of the lecturers via independent written feedback from trained undergraduate students and surgeons. The 22-item feedback instrument covered three areas of performance: content, visualization, and delivery. Additional suggestions for improvement were provided from both students and surgical peers who anonymously attended the lectures. The lecturers, experienced surgeons, as well as the student and peer raters were blinded in terms of the aim and content of the study. Their response to the feedback was collected using a web-based 13-item questionnaire. The Kendall’s-W coefficient was computed to calculate inter-rater reliability (IRR). Differences between ratings before and after feedback were analyzed using Student’s t-test for dependent samples. The Kolmogorov-Smirnov-test was used for independent samples. Results A total of 22 lectures from a possible 32 given by 13 lecturers were included and analyzed by at least three surgeons and two students. There were significant improvements in overall score as well as in the details of 9 of the 13 items were found. The average inter-rater reliability was 0.71. There were no differences in the ratings as a function of the rater’s level of expertise (peers vs. students). We found that 13/23 lecturers (56.5%) answered the questionnaire, and 92% strongly agreed that the written feedback was useful. 76.9% of the lecturers revised their lecture based on the written feedback requiring on average 112.5 min (range from 20 to 300 min). Conclusions Overall, this study indicates that structured written feedback provided by trained peers and students that is subsequently discussed by the lecturers concerned is a highly effective and efficient method to improve aspects of lecturing. We anticipate that structured written feedback by trained students that is discussed by the lecturers concerned will improve lecturing

    Acetabular fractures treatment needs in the elderly and nonagenarians

    No full text
    Different treatment options for acetabular fractures in the elderly and nonagenarians exist; a consistent guideline has not been established, yet. The purpose of this study is to give an overview of how those fractures can be handled and compares two different surgical treatment methods. A total of 89 patients ≥ 18 years between 2016 and 2021 with acetabular fractures in our department received a surgical intervention with plate fixation via the Stoppa approach or a total hip arthroplasty with a Burch–Schneider ring and integrated cup. 60 patients ≥ 65 were compared in two groups, 29 patients between 65 and 79 and 31 patients ≥ 80. For comparison, data on operation times, hospitalization, complications during operation and hospital stay, blood loss and postoperative mobilization were collected. Characteristics could be found for indications for operative osteosynthesis or endoprosthetics based on the X-ray analysis. There was a tendency to treat simple fractures with osteosynthesis. Patients between 65 and 79 with an osteosynthesis had benefits in almost every comparison. Patients ≥ 80 with a plate fixation had advantages in the categories of postoperative complications, blood loss and transfusion of erythrocyte concentrates. Statistical significant differences were noticed in both groups regarding the operation time. Patients between 65 and 79 with osteosynthesis had significant benefits for postoperative complications, hospitalization, number of blood transfusions and postoperative mobilization. Finding the best supportive treatment option is difficult, and decision-making must respect fracture patterns and individual risk factors. This study shows that plate fixation via the Stoppa approach has some benefits

    The implementation of a complication avoidance care bundle significantly reduces adverse surgical outcomes in orthopedic trauma patients

    No full text
    Background: Surgical complications are associated with a significant burden to patients and hospitals and are increasingly discussed in recent literature. This cohort study reviewed surgery-related complications in a Level I trauma center. The effect of a complication avoidance care bundle on the rate of surgical complications was analyzed. Methods: All complications (surgical and nonsurgical) that occur in our trauma department are prospectively captured using a standardized documentation form and are discussed and analyzed in a weekly trauma Morbidity and Mortality (M&M) conference. Surgical complication rates are calculated using the annual surgical procedure numbers. Based on discussions in the M&M conference, a complication avoidance care bundle consisting of five measures was established: (1) Improving team situational awareness; (2) reducing operating room traffic by staff members and limiting door-opening events; (3) preoperative screening for infectious foci; (4) adapted preoperative antibiotic prophylaxis in anatomic regions with a high risk of infectious complications; and (5) use of iodine-impregnated adhesive drape. Results: The number of surgical procedures steadily increased over the study years, from 3587 in 2015 to 3962 in 2019 (an increase of 10.5%). Within this 5-year study period, the overall rate of surgical complications was 0.8%. Surgical site infections were the most frequently found complications (n = 40, 24.8% of all surgical complications), followed by screw malposition (n = 20, 12.4%), postoperative dislocations of arthroplasties (n = 18, 11.2%), and suboptimal fracture reduction (n = 18, 11.2%). Following implementation of the complication avoidance care bundle, the overall rate of surgical complications significantly decreased, from 1.14% in the year 2016 to 0.56% in the study year 2019, which represents a reduction of 51% within a 3-year time period. Conclusions: A multimodal strategy targeted at reducing the surgical complication rate can be successfully established based on a transparent discussion of adverse surgical outcomes. The combination of the different preventive measures was associated with reducing the overall complication rate by half within a 3-year time period
    corecore