20 research outputs found

    Deep learning-based classification of organs at risk and delineation guideline in pelvic cancer radiation therapy

    No full text
    Deep learning (DL) models for radiation therapy (RT) image segmentation require accurately annotated training data. Multiple organ delineation guidelines exist; however, information on the used guideline is not provided with the delineation. Extraction of training data with coherent guidelines can therefore be challenging. We present a supervised classification method for pelvis structure delineations where bowel cavity, femoral heads, bladder, and rectum data, with two guidelines, were classified. The impact on DL-based segmentation quality using mixed guideline training data was also demonstrated. Bowel cavity was manually delineated on CT images for anal cancer patients (n = 170) according to guidelines Devisetty and RTOG. The DL segmentation quality from using training data with coherent or mixed guidelines was investigated. A supervised 3D squeeze-and-excite SENet-154 model was trained to classify two bowel cavity delineation guidelines. In addition, a pelvis CT dataset with manual delineations from prostate cancer patients (n = 1854) was used where data with an alternative guideline for femoral heads, rectum, and bladder were generated using commercial software. The model was evaluated on internal (n = 200) and external test data (n = 99). By using mixed, compared to coherent, delineation guideline training data mean DICE score decreased 3% units, mean Hausdorff distance (95%) increased 5 mm and mean surface distance (MSD) increased 1 mm. The classification of bowel cavity test data achieved 99.8% unweighted classification accuracy, 99.9% macro average precision, 97.2% macro average recall, and 98.5% macro average F1. Corresponding metrics for the pelvis internal test data were all 99% or above and for the external pelvis test data they were 96.3%, 96.6%, 93.3%, and 94.6%. Impaired segmentation performance was observed for training data with mixed guidelines. The DL delineation classification models achieved excellent results on internal and external test data. This can facilitate automated guideline-specific data extraction while avoiding the need for consistent and correct structure labels

    MRI-only radiotherapy of gliomas – a prospective implementation study.

    No full text
    Minna Lerner, Joakim Medin, Christian Jamtheim Gustafsson, Sara Alkner and Lars E. Olsson

    Prospective Clinical Feasibility Study for MRI-Only Brain Radiotherapy

    No full text
    Objectives: MRI-only radiotherapy (RT) provides a workflow to decrease the geometric uncertainty introduced by the image registration process between MRI and CT data and to streamline the RT planning. Despite the recent availability of validated synthetic CT (sCT) methods for the head region, there are no clinical implementations reported for brain tumors. Based on a preceding validation study of sCT, this study aims to investigate MRI-only brain RT through a prospective clinical feasibility study with endpoints for dosimetry and patient setup. Material and Methods: Twenty-one glioma patients were included. MRI Dixon images were used to generate sCT images using a CE-marked deep learning-based software. RT treatment plans were generated based on MRI delineated anatomical structures and sCT for absorbed dose calculations. CT scans were acquired but strictly used for sCT quality assurance (QA). Prospective QA was performed prior to MRI-only treatment approval, comparing sCT and CT image characteristics and calculated dose distributions. Additional retrospective analysis of patient positioning and dose distribution gamma evaluation was performed. Results: Twenty out of 21 patients were treated using the MRI-only workflow. A single patient was excluded due to an MRI artifact caused by a hemostatic substance injected near the target during surgery preceding radiotherapy. All other patients fulfilled the acceptance criteria. Dose deviations in target were within ±1% for all patients in the prospective analysis. Retrospective analysis yielded gamma pass rates (2%, 2 mm) above 99%. Patient positioning using CBCT images was within ± 1 mm for registrations with sCT compared to CT. Conclusion: We report a successful clinical study of MRI-only brain radiotherapy, conducted using both prospective and retrospective analysis. Synthetic CT images generated using the CE-marked deep learning-based software were clinically robust based on endpoints for dosimetry and patient positioning

    MRI-only based treatment with a commercial deep-learning generation method for synthetic CT of brain

    No full text
    ObjectivesTo show feasibility of synthetic computed tomography (sCT) images generated using a commerciallyavailable software, enabling MRI-only treatment planning for the brain in a clinical setting.Patients and Methods20 and 16 patients with brain malignancies, including post-surgical cases, were included for validationand treatment, respectively. Dixon MR images of the skull were exported to the MRI Planner software(Spectronic Medical AB), which utilizes convolutional neural network algorithms for sCT generation.In the validation study, sCT images were rigidly registered and resampled to CT geometry for eachpatient. Treatment plans were optimized on CT and retrospectively recalculated on sCT images forevaluation of dosimetric and geometric endpoints. Clinical robustness in patient setup verification wasassessed by rigidly registering cone beam CT (CBCT) to sCT and CT images, respectively.The treatment study was performed on sCT images, using CT solely for QA purposes.ResultsAll sCT images were successfully generated in the validation study. Mean absolute error of the sCTimages within the body contour for all patients was 62.2 ± 4.1 HU. Average absorbed dose differenceswere below 0.2%. Mean pass rate of global gamma (1%/1mm) for all patients was 100.0 ± 0.0 % withinPTV and 99.1 ± 0.6 % for the full dose distribution. No clinically relevant deviations were found in theCBCT-sCT vs CBCT-CT image registrations. Areas of bone resection due to surgery were accuratelydepicted in the sCT images. Finally, treatment success rate was 15/16. One patient was excluded due tosCT artifacts from a haemostatic substance injected during surgery.Conclusion15 patients have successfully received MRI-only RT for brain tumours using the validated commerciallyavailable sCT software. Validation showed comparable results between sCT and CT images for bothdosimetric and geometric endpoint

    Development and evaluation of a deep learning based artificial intelligence for automatic identification of gold fiducial markers in an MRI-only prostate radiotherapy workflow

    No full text
    Identification of prostate gold fiducial markers in magnetic resonance imaging (MRI) images is challenging when CT images are not available, due to misclassifications from intra-prostatic calcifications. It is also a time consuming task and automated identification methods have been suggested as an improvement for both objectives. Multi-echo gradient echo (MEGRE) images have been utilized for manual fiducial identification with 100% detection accuracy. The aim is therefore to develop an automatic deep learning based method for fiducial identification in MRI images intended for MRI-only prostate radiotherapy. MEGRE images from 326 prostate cancer patients with fiducials were acquired on a 3T MRI, post-processed with N4 bias correction, and the fiducial center of mass (CoM) was identified. A 9 mm radius sphere was created around the CoM as ground truth. A deep learning HighRes3DNet model for semantic segmentation was trained using image augmentation. The model was applied to 39 MRI-only patients and 3D probability maps for fiducial location and segmentation were produced and spatially smoothed. In each of the three largest probability peaks, a 9 mm radius sphere was defined. Detection sensitivity and geometric accuracy was assessed. To raise awareness of potential false findings a 'BeAware' score was developed, calculated from the total number and quality of the probability peaks. All datasets, annotations and source code used were made publicly available. The detection sensitivity for all fiducials were 97.4%. Thirty-six out of thirty-nine patients had all fiducial markers correctly identified. All three failed patients generated a user notification using the BeAware score. The mean absolute difference between the detected fiducial and ground truth CoM was 0.7 ± 0.9 [0 3.1] mm. A deep learning method for automatic fiducial identification in MRI images was developed and evaluated with state-of-the-art results. The BeAware score has the potential to notify the user regarding patients where the proposed method is uncertain

    Geometric impact and dose estimation of on-patient placement of a lightweight receiver coil in a clinical magnetic resonance imaging-only radiotherapy workflow for prostate cancer

    No full text
    Background and Purpose: For pelvic magnetic resonance imaging (MRI)-only radiotherapy the use of receiver coil bridges (CB) is recommended to avoid deformation of the patient. Development in coil technology has enabled lightweight, flexible coils. In this work we evaluate the effects of a lightweight coil in a pelvic MRI-only radiotherapy workflow. Materials and Methods: Twenty-one patients, referred to prostate MRI-only radiotherapy, were included. Images were acquired with and without CB. Anatomical deformation from the on-patient coil placement was measured in the anterior-posterior (AP) and left–right (LR) direction. The change in signal-to-noise ratio (SNR) was measured in phantom and in vivo.The clinical treatment plan, created on the image with CB, was transferred and recalculated on the image without the CB. Dose metrics for the targets (planning- and clinical target volume) and organs at risks (OAR) were analyzed. Results: There was a statistically significant increase in SNR in-vivo (median 21 %, p = 0.002) when removing the CB. Anatomical differences after removing the CB in patients were −1.5 mm in AP (median change) and + 2.5 mm in LR direction. Dosimetric differences for the target structures were clinically negligible, but statistically significant. The difference in target mean doses were 0.2 % (both p = 0.004) of the prescribed dose. No dosimetric differences were observed for the OAR, except for the penile bulb. Conclusions: We concluded that anatomical change and dosimetric differences, originating from scanning without CB were minor. The CB can thereby be removed from the workflow, enabling easier patient positioning and increased SNR when using lightweight coils

    Clinical validation of a commercially available deep learning software for synthetic CT generation for brain

    No full text
    Background: Most studies on synthetic computed tomography (sCT) generation for brain rely on in-house developed methods. They often focus on performance rather than clinical feasibility. Therefore, the aim of this work was to validate sCT images generated using a commercially available software, based on a convolutional neural network (CNN) algorithm, to enable MRI-only treatment planning for the brain in a clinical setting. Methods: This prospective study included 20 patients with brain malignancies of which 14 had areas of resected skull bone due to surgery. A Dixon magnetic resonance (MR) acquisition sequence for sCT generation was added to the clinical brain MR-protocol. The corresponding sCT images were provided by the software MRI Planner (Spectronic Medical AB, Sweden). sCT images were rigidly registered and resampled to CT for each patient. Treatment plans were optimized on CT and recalculated on sCT images for evaluation of dosimetric and geometric endpoints. Further analysis was also performed for the post-surgical cases. Clinical robustness in patient setup verification was assessed by rigidly registering cone beam CT (CBCT) to sCT and CT images, respectively. Results: All sCT images were successfully generated. Areas of bone resection due to surgery were accurately depicted. Mean absolute error of the sCT images within the body contour for all patients was 62.2 ± 4.1 HU. Average absorbed dose differences were below 0.2% for parameters evaluated for both targets and organs at risk. Mean pass rate of global gamma (1%/1 mm) for all patients was 100.0 ± 0.0% within PTV and 99.1 ± 0.6% for the full dose distribution. No clinically relevant deviations were found in the CBCT-sCT vs CBCT-CT image registrations. In addition, mean values of voxel-wise patient specific geometric distortion in the Dixon images for sCT generation were below 0.1 mm for soft tissue, and below 0.2 mm for air and bone. Conclusions: This work successfully validated a commercially available CNN-based software for sCT generation. Results were comparable for sCT and CT images in both dosimetric and geometric evaluation, for both patients with and without anatomical anomalies. Thus, MRI Planner is feasible to use for radiotherapy treatment planning of brain tumours

    Evalutation of two commercial deep learning OAR segmentation models for prostate cancer treatment

    No full text
    Purpose or ObjectiveTo evaluate two commercial, CE labeled deep learning-based models for automatic organs at risk segmentation on planning CT images for prostate cancer radiotherapy. Model evaluation was focused on assessing both geometrical metrics and evaluating a potential time saving.Material and MethodsThe evaluated models consisted of RayStation 10B Deep Learning Segmentation (RaySearch Laboratories AB, Stockholm, Sweden) and MVision AI Segmentation Service (MVision, Helsinki, Finland) and were applied to CT images for a dataset of 54 male pelvis patients. The RaySearch model was re-trained with 44 clinic specific patients (Skåne University Hospital, Lund, Sweden) for the femoral head structures to adjust the model to our specific delineation guidelines. The model was evaluated on 10 patients from the same clinic. Dice similarity coefficient (DSC) and Hausdorff distance (95th percentile) was computed for model evaluation, using an in-house developed Python script. The average time for manual and AI model delineations was recorded.ResultsAverage DSC scores and Hausdorff distances for all patients and both models are presented in Figure 1 and Table 1, respectively. The femoral head segmentations in the re-trained RaySearch model had increased overlap with our clinical data, with a DSC (mean±1 STD) for the right femoral head of 0.55±0.06 (n=53) increasing to 0.91±0.02 (n=10) and mean Hausdorff (mm) decreasing from 55±7 (n=53) to 4±1 (n=10) (similar results for the left femoral head). The deviation in femoral head compared to the RaySearch and MVision original models occurred due to a difference in the femoral head segmentation guideline in the clinic specific data, see Figure 2. Time recording of manual delineation was 13 minutes compared to 0.5 minutes (RaySearch) and 1.4 minutes (MVision) for the AI models, manual correction not included.ConclusionBoth AI models demonstrate good segmentation performance for bladder and rectum. Clinic specific training data (or data that complies to the clinic specific delineation guideline) might be necessary to achieve segmentation results in accordance to the clinical specific standard for some anatomical structures, such as the femoral heads in our case. The time saving was around 90%, not including manual correction
    corecore