The virtual cone: A novel technique to generate spherical dose distributions using a multileaf collimator and standardized control-point sequence for small target radiation surgery
Purpose: The study aimed to develop and demonstrate a standardized linear accelerator multileaf collimator-based method of delivering small, spherical dose distributions suitable for radiosurgical treatment of small targets such as the trigeminal nerve. Methods and materials: The virtual cone is composed of a multileaf collimator–defined field with the central 2 leaves set to a small gap. For 5 table positions, clockwise and counter-clockwise arcs were used with collimator angles of 45 and 135 degrees, respectively. The dose per degree was proportional to the sine of the gantry angle. The dose distribution was calculated by the treatment planning system and measured using radiochromic film in a skull phantom for leaf gaps of 1.6, 2.1, and 2.6 mm. Cones with a diameter of 4 mm and 5 mm were measured for comparison. Output factor constancy was investigated using a parallel-plate chamber. Results: The mean ratio of the measured-to-calculated dose was 0.99, 1.03, and 1.05 for 1.6, 2.1, and 2.6 mm leaf gaps, respectively. The diameter of the measured (calculated) 50% isodose line was 4.9 (4.6) mm, 5.2 (5.1) mm, and 5.5 (5.5) mm for the 1.6, 2.1, and 2.6 mm leaf gap, respectively. The measured diameter of the 50% isodose line was 4.5 and 5.7 mm for the 4 mm and 5 mm cones, respectively. The standard deviation of the parallel-plate chamber signal relative to a 10 cm × 10 cm field was less than 0.4%. The relative signal changed 32% per millimeter change in leaf gap, indicating that the parallel-plate chamber is sensitive to changes in gap width. Conclusions: The virtual cone is an efficient technique for treatment of small spherical targets. Patient-specific quality assurance measurements will not be necessary in routine clinical use. Integration directly into the treatment planning system will make planning using this technique extremely efficient
Fractionated stereotactic radiation therapy for intact brain metastases
Purpose: Limited data exist on fractionated stereotactic radiation therapy (FSRT) for brain metastases. We sought to evaluate the safety and efficacy of FSRT and further define its role in brain metastasis management. Methods and materials: A total of 72 patients were treated with linear accelerator–based FSRT to 182 previously untreated, intact brain metastases. Targets received 25 or 30 Gy in 5 fractions. All targets within the same course received the same prescription regardless of size. Toxicity was recorded per Radiation Therapy Oncology Group central nervous system toxicity criteria. Results: The median follow-up was 5 months (range, 1-71 months). The Kaplan-Meier estimate of 12-month local control was 86%. Tumors <3 cm in diameter demonstrated improved 12-month local control of 95% compared with 61% in tumors ≥3 cm (P < .001). The Kaplan-Meier estimate of 12-month local control was 91% in tumors treated with 30 Gy and only 75% in tumors treated with 25 Gy (P = .015). Tumor diameter ≥3 cm resulted in increased local failure, and a 30 Gy prescription resulted in decreased local failure on multivariate analysis (hazard ratio [HR], 8.11 [range, 2.09-31.50; P = .003] and HR, 0.26 [range, 0.07-0.93; P = .038]). Grade 4 central nervous system toxicity occurred in 4 patients (6%) requiring surgery, and no patient experienced irreversible grade 3 or 5 toxicity. Increasing tumor diameter was associated with increased toxicity risk (HR, 2.45 [range, 1.04-5.742; P = .04]). Conclusions: FSRT for brain metastases appears to demonstrate a high rate of local control with minimal risk of severe toxicity. Local control appears to be associated with smaller tumor sizeand a higher prescription dose. FSRT is a viable option for those who are poor single-fraction candidates
A phase 2 study of radiosurgery and temozolomide for patients with 1 to 4 brain metastases
Purpose: To determine if temozolomide reduces the risk of distant brain failure (DBF, metachronous brain metastases) in patients with 1 to 4 brain metastases treated with radiosurgery without whole-brain radiation therapy (WBRT).
Methods and materials: Twenty-five patients with newly diagnosed brain metastases were enrolled in a single institution phase 2 trial of radiosurgery (15-24 Gy) and adjuvant temozolomide. Temozolomide was continued for a total of 12 cycles unless the patient developed DBF, unacceptable toxicity, or systemic progression requiring other therapy.
Results: Twenty-five patients were enrolled between 2002 and 2005; 3 were not evaluable for determining DBF. Of the remaining 22 patients, tumor types included non-small cell lung cancer (n = 8), melanoma (n = 7), and other (n = 7). Extracranial disease was present in 10 (45%) patients. The median number of tumors at the time of radiosurgery was 3 (range, 1-6). The median overall survival was 31 weeks. The median radiographic follow-up for patients who did not develop DBF was 33 weeks. Six patients developed DBF. The 1-year actuarial risk of DBF was 37%.
Conclusions: In this study, there was a relatively low risk of distant brain failure observed in the nonmelanoma subgroup receiving temozolamide. However, patient selection factors rather than chemotherapy treatment efficacy are more likely the reason for the relatively low risk of distant brain failure observed in this study. Future trial design should account for these risk factors