235 research outputs found
SEAPAK user's guide, version 2.0. Volume 1: System description
The SEAPAK is a user interactive satellite data analysis package that was developed for the processing and interpretation of Nimbus-7/Coastal Zone Color Scanner (CZCS) and the NOAA Advanced Very High Resolution Radiometer (AVHRR) data. Significant revisions were made to version 1.0 of the guide, and the ancillary environmental data analysis module was expanded. The package continues to emphasize user friendliness and user interactive data analyses. Additionally, because the scientific goals of the ocean color research being conducted have shifted to large space and time scales, batch processing capabilities for both satellite and ancillary environmental data analyses were enhanced, thus allowing large quantities of data to be ingested and analyzed in background
SEAPAK user's guide, version 2.0. Volume 2: Descriptions of programs
The SEAPAK is a user-interactive satellite data analysis package that was developed for the processing and interpretation of Nimbus-7/Coastal Zone Color Scanner (CZCS) and the NOAA Advanced Very High Resolution Radiometer (AVHRR) data. Significant revisions were made since version 1.0, and the ancillary environmental data analysis module was greatly expanded. The package continues to be user friendly and user interactive. Also, because the scientific goals of the ocean color research being conducted have shifted to large space and time scales, batch processing capabilities for both satellite and ancillary environmental data analyses were enhanced, thus allowing for large quantities of data to be ingested and analyzed
Reshaping Practitioner Higher Education Institutions to Serve Adult Learners: The COVID-19 Pandemic Implications
Involving over 200 countries, the COVID-19 global pandemic impacts adult learners’ retention, increasing the need to reshape practitioner-oriented higher education institutions to better serve students. The purpose of this study was to explore how practitioner higher education institutions adopted innovative approaches and reshaped policies, practices, and perspectives to accommodate changes brought about by the COVID- 19 pandemic and successfully maintained or increased enrollment. This article reports the results, which may enhance practitioner higher education programs and enrollment
Variability of Surface Pigment Concentrations in the South Atlantic Bight
A 1‐year time sequence (November 1978 through October 1979) of surface pigment images from the South Atlantic Bight (SAB) was derived from the Nimbus 7 coastal zone color scanner. This data set is augmented with in situ observations of hydrographic parameters, freshwater discharge, sea level, coastal winds, and currents for the purpose of examining the coupling between physical processes and the spatial and temporal variability of the surface pigment fields. The SAB is divided into three regions: the east Florida shelf, the Georgia‐South Carolina shelf and the Carolina Capes. Six‐month seasonal mean pigment fields and time series of mean values within subregions were generated. While the seasonal mean isopleths were closely oriented along isobaths, significant differences between seasons in each region were found to exist. These differences are explained by correlating the pigment time series with physical parameters and processes known to be important in the SAB. Specifically, summertime concentrations between Cape Romain and Cape Canaveral were greater than those in winter, but the opposite was true north of Cape Romain. It is suggested that during the abnormally high freshwater discharge in the winter‐spring of 1979, Cape Romain and Cape Fear were the major sites of cross‐shelf transport, while the cross‐shelf exchange during the fall of 1979 occurred just north of Cape Canaveral. Finally, the alongshore band of high pigment concentrations increased in width throughout the year in the vicinity of Charleston, but near Jacksonville it exhibited a minimum width in the summer and a maximum width in the fall of 1979
SeaWiFS technical report series. Volume 20: The SeaWiFS bio-optical archive and storage system (SeaBASS), part 1
This document provides an overview of the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Bio-Optical Archive and Storage System (SeaBASS), which will serve as a repository for numerous data sets of interest to the SeaWiFS Science Team and other approved investigators in the oceanographic community. The data collected will be those data sets suitable for the development and evaluation of bio-optical algorithms which include results from SeaWiFS Intercalibration Round-Robin Experiments (SIRREXs), prelaunch characterization of the SeaWiFS instrument by its manufacturer -- Hughes/Santa Barbara Research Center (SBRC), Marine Optical Characterization Experiment (MOCE) cruises, Marine Optical Buoy (MOBY) deployments and refurbishments, and field studies of other scientists outside of NASA. The primary goal of the data system is to provide a simple mechanism for querying the available archive and requesting specific items, while assuring that the data is made available only to authorized users. The design, construction, and maintenance of SeaBASS is the responsibility of the SeaWiFS Calibration and Validation Team (CVT). This report is concerned with documenting the execution of this task by the CVT and consists of a series of chapters detailing the various data sets involved. The topics presented are as follows: 1) overview of the SeaBASS file architecture, 2) the bio-optical data system, 3) the historical pigment database, 4) the SIRREX database, and 5) the SBRC database
SeaWiFS technical report series. Volume 22: Prelaunch acceptance report for the SeaWFS radiometer
The final acceptance, or rejection, of the Sea-viewing Wide field-of-view Sensor (SeaWiFS) will be determined by the instrument's on-orbit operation. There is, however, an extensive set of laboratory measurements describing the operating characteristics of the radiometer. Many of the requirements in the Ocean Color Data Mission (OCDM) specifications can be checked only by laboratory measurements. Here, the calibration review panel (composed of the authors of this technical memorandum) examines the laboratory characterization and calibration of SeaWiFS in the light of the OCDM performance specification. Overall, the performance of the SeaWiFS instrument meets or exceeds the requirements of the OCDM contract in all but a few unimportant details. The detailed results of this examination are presented here by following the outline of the specifications, as found in the Contract. The results are presented in the form of requirements and compliance pairs. These results give conclusions on many, but not all, of the performance specifications. The acceptance of this panel of the performance of SeaWiFS must only be considered as an intermediate conclusion. The ultimate acceptance (or rejection) of the SeaWiFS data set will rely on the measurements made by the instrument on orbit
Electronic feedback in a diet- and physical activity-based lifestyle intervention for weight loss: a randomized controlled trial
<p>Abstract</p> <p>Background</p> <p>The SenseWear™ Armband (SWA) (BodyMedia, Inc. Pittsburgh, PA) is a physical activity and lifestyle monitor that objectively and accurately measures free-living energy balance and sleep and includes software for self-monitoring of daily energy expenditure and energy intake. The real-time feedback of the SWA can improve individual self-monitoring and, therefore, enhance weight loss outcomes.</p> <p>Methods</p> <p>We recruited 197 sedentary overweight or obese adults (age, 46.8 ± 10.8 y; body mass index (BMI), 33.3 ± 5.2 kg/m<sup>2</sup>; 81% women, 32% African-American) from the greater Columbia, South Carolina area. Participants were randomized into 1 of 4 groups, a self-directed weight loss program via an evidence-based weight loss manual (Standard Care, n = 50), a group-based behavioral weight loss program (GWL, n = 49), the armband alone (SWA-alone, n = 49), or the GWL plus the armband (GWL+SWA, n = 49), during the 9-month intervention. The primary outcome was change in body weight and waist circumference. A mixed-model repeated-measures analysis compared change in the intervention groups to the standard care group on weight and waist circumference status after adjusting for age, sex, race, education, energy expenditure, and recruitment wave.</p> <p>Results</p> <p>Body weight was available for 62% of participants at 9 months (52% standard care, 70% intervention). There was significant weight loss in all 3 intervention groups (GWL, 1.86 kg, P = 0.05; SWA-alone, 3.55 kg, P = 0.0002; GWL+SWA, 6.59 kg, P < 0.0001) but not in the Standard Care group (0.89 kg, P = 0.39) at month 9. Only the GWL+SWA group achieved significant weight loss at month 9 compared to the Standard Care group (P = 0.04). Significant waist circumference reductions were achieved in all 4 groups at month 9 (Standard Care, 3.49 cm, P = 0.0004; GWL, 2.42 cm, P = 0.008; SWA-alone, 3.59 cm, P < 0.0001; GWL+SWA, 6.77 cm, P < 0.0001), but no intervention group had significantly reduced waist circumference compared to the Standard Care group.</p> <p>Conclusions</p> <p>Continuous self-monitoring from wearable technology with real-time feedback may be particularly useful to enhance lifestyle changes that promote weight loss in sedentary overweight or obese adults. This strategy, combined with a group-based behavioral intervention, may yield optimal weight loss.</p> <p>Trial Registration</p> <p>ClinicalTrials.gov: <a href="http://www.clinicaltrials.gov/ct2/show/NCT00957008">NCT00957008</a></p
SeaWiFS Technical Report Series. Volume 22: Prelaunch Acceptance Report for the SeaWiFS Radiometer
The final acceptance, or rejection, of the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) will be determined by the instrument's on-orbit operation. There is, however, an extensive set of laboratory measurements describing the operating characteristics of the radiometer. Many of the requirements in the Ocean Color Data Mission (OCDM) specifications can be checked only by laboratory measurements. Here, the calibration review panel examines the laboratory characterization and calibration of SeaWiFS in the light of the OCDM performance specification. Overall, the performance of the SeaWiFS instrument meets or exceeds the requirements of the OCDM contract in all but a few unimportant details. The detailed results of this examination are presented here by following the outline of the specifications, as found in the Contract. The results are presented in the form of requirements and compliance pairs. These results give conclusions on many, but not all, of the performance specifications. The acceptance by this panel of the performance of SeaWiFS must only be considered as an intermediate conclusion. The ultimate acceptance (or rejection) of the SeaWiFS data set will rely on the measurements made by the instrument on orbit
Issues in accelerometer methodology: the role of epoch length on estimates of physical activity and relationships with health outcomes in overweight, post-menopausal women
<p>Abstract</p> <p>Background</p> <p>Current accelerometer technology allows for data collection using brief time sampling intervals (i.e., epochs). The study aims were to examine the role of epoch length on physical activity estimates and subsequent relationships with clinically-meaningful health outcomes in post-menopausal women.</p> <p>Methods</p> <p>Data was obtained from the Woman On the Move through Activity and Nutrition Study (n = 102). Differences in activity estimates presented as 60s and 10s epochs were evaluated using paired t-tests. Relationships with health outcomes were examined using correlational and regression analyses to evaluate differences by epoch length.</p> <p>Results</p> <p>Inactivity, moderate- and vigorous-intensity activity (MVPA) were significantly higher and light-intensity activity was significantly lower (all <it>P </it>< 0.001) when presented as 10s epochs. The correlation between inactivity and self-reported physical activity was stronger with 10s estimates (<it>P </it>< 0.03); however, the regression slopes were not significantly different. Conversely, relationships between MVPA and body weight, BMI, whole body and trunk lean and fat mass, and femoral neck bone mineral density was stronger with 60s estimates (all <it>P </it>< 0.05); however, regression slopes were similar.</p> <p>Conclusion</p> <p>These findings suggest that although the use of a shorter time sampling interval may suggestively reduce misclassification error of physical activity estimates, associations with health outcomes did not yield strikingly different results. Additional studies are needed to further our understanding of the ways in which epoch length contributes to the ascertainment of physical activity in research studies.</p> <p>Trial Registration</p> <p>Clinical Trials Identifier: NCT00023543</p
60 kD Ro and nRNP A Frequently Initiate Human Lupus Autoimmunity
Systemic lupus erythematosus (SLE) is a clinically heterogeneous, humoral autoimmune disorder. The unifying feature among SLE patients is the production of large quantities of autoantibodies. Serum samples from 129 patients collected before the onset of SLE and while in the United States military were evaluated for early pre-clinical serologic events. The first available positive serum sample frequently already contained multiple autoantibody specificities (65%). However, in 34 SLE patients the earliest pre-clinical serum sample positive for any detectable common autoantibody bound only a single autoantigen, most commonly 60 kD Ro (29%), nRNP A (24%), anti-phospholipids (18%) or rheumatoid factor (15%). We identified several recurrent patterns of autoantibody onset using these pre-diagnostic samples. In the serum samples available, anti-nRNP A appeared before or simultaneously with anti-nRNP 70 K in 96% of the patients who had both autoantibodies at diagnosis. Anti-60 kD Ro antibodies appeared before or simultaneously with anti-La (98%) or anti-52 kD Ro (95%). The autoantibody response in SLE patients begins simply, often binding a single specific autoantigen years before disease onset, followed by epitope spreading to additional autoantigenic specificities that are accrued in recurring patterns
- …