    Development and evaluation of topical gabapentin formulations

    Get PDF
    Topical delivery of gabapentin is desirable to treat peripheral neuropathic pain conditions whilst avoiding systemic side effects. To date, reports of topical gabapentin delivery in vitro have been variable and dependent on the skin model employed, primarily involving rodent and porcine models. In this study a variety of topical gabapentin formulations were investigated, including Carbopol® hydrogels containing various permeation enhancers, and a range of proprietary bases including a compounded Lipoderm® formulation; furthermore microneedle facilitated delivery was used as a positive control. Critically, permeation of gabapentin across a human epidermal membrane in vitro was assessed using Franz-type diffusion cells. Subsequently this data was contextualised within the wider scope of the literature. Although reports of topical gabapentin delivery have been shown to vary, largely dependent upon the skin model used, this study demonstrated that 6% (w/w) gabapentin 0.75% (w/w) Carbopol® hydrogels containing 5% (w/w) DMSO or 70% (w/w) ethanol and a compounded 10% (w/w) gabapentin Lipoderm® formulation were able to facilitate permeation of the molecule across human skin. Further pre-clinical and clinical studies are required to investigate the topical delivery performance and pharmacodynamic actions of prospective formulations

    Formulation of hydrophobic peptides for skin delivery via coated microneedles

    Get PDF
    Microneedles (MNs) have been investigated as a minimally-invasive delivery technology for a range of active pharmaceutical ingredients (APIs). Various formulations and methods for coating the surface of MNs with therapeutics have been proposed and exemplified, predominantly for hydrophilic drugs and particulates. The development of effective MN delivery formulations for hydrophobic drugs is more challenging with dosing restrictions and the use of organic solvents impacting on both the bioactivity and the kinetics of drug release. In this study we propose a novel formulation that is suitable for MN coating of hydrophobic auto-antigen peptides currently being investigated for antigen specific immunotherapy (ASI) of type 1 diabetes. The formulation, comprising three co-solvents (water, 2-methyl-2-butanol and acetic acid) and polyvinylalcohol 2000 (PVA2000) can dissolve both hydrophilic and hydrophobic peptide auto-antigens at relatively high, and clinically relevant, concentrations (25 mg/ml or 12.5 mg/ml). The drug:excipient ratio is restricted to 10:1 w/w to maximise dose whilst ensuring that the dry-coated payload does not significantly impact on MN skin penetration performance. The coating formulation and process does not adversely affect the biological activity of the peptide. The delivery efficiency of the coated peptide into skin is influenced by a number of parameters. Electropolishing the metal MN surface increases delivery efficiency from 2.0 ± 1.0% to 59.9 ± 6.7%. An increased mass of peptide formulation per needle, from 0.37 μg to 2 μg peptide dose, resulted in a thicker coating and a 20% reduction in the efficiency of skin delivery. Other important performance parameters for coated MNs include the role of excipients in assisting dissolution from the MNs, the intrinsic hydrophobicity of the peptide and the species of skin model used in laboratory studies. This study therefore both exemplifies the potential of a novel formulation for coating hydrophobic and hydrophilic peptides onto MN devices and provides new insight into the factors that influence delivery efficiency from coated MNs. Importantly, the results provide guidance for identifying critical attributes of the formulation, coating process and delivery device, that confer reproducible and effective delivery from coated MNs, and thus contribute to the requirements of the regulators appraising these devices

    Editorial

    Get PDF

    Models and methods to characterise levonorgestrel release from intradermally administered contraceptives

    Get PDF
    Microneedle (MN)-based technologies have been proposed as a means to facilitate minimally invasive sustained delivery of long-acting hormonal contraceptives into the skin. Intradermal administration is a new route of delivery for these contraceptives and therefore no established laboratory methods or experimental models are available to predict dermal drug release and pharmacokinetics from candidate MN formulations. This study evaluates an in vitro release (IVR) medium and a medium supplemented with ex vivo human skin homogenate (SH) as potential laboratory models to investigate the dermal release characteristics of one such hormonal contraceptive that is being tested for MN delivery, levonorgestrel (LNG), and provides details of an accompanying novel two-step liquid–liquid drug extraction procedure and sensitive reversed-phase HPLC–UV assay. The extraction efficiency of LNG was 91.7 ± 3.06% from IVR medium and 84.6 ± 1.6% from the medium supplemented with SH. The HPLC–UV methodology had a limit of quantification of 0.005 µg/mL and linearity between 0.005 and 25 µg/mL. Extraction and detection methods for LNG were exemplified in both models using the well-characterised, commercially available sustained-release implant (Jadelle®). Sustained LNG release from the implant was detected in both media over 28 days. This study reports for the first time the use of biologically relevant release models and a rapid, reliable and sensitive methodology to determine release characteristics of LNG from intradermally administered long-acting drug delivery systems

    Langerin (CD207) represents a novel interferon-stimulated gene in Langerhans cells

    Get PDF
    Interferons (IFNs) are “warning signal” cytokines released upon pathogen sensing. IFNs control the expression of interferon-stimulated genes (ISGs), which are often crucial to restrict viral infections and establish a cellular antiviral state.1,2 Langerin (CD207), a well-known surface receptor on Langerhans cells (LC), belongs to the C-type lectin receptor (CLR) family and constitutes a major pathogen binding receptor able to regulate both innate and adaptive immune responses.3,4 Importantly, this CLR was reported as an antiviral receptor, notably able to bind and internalize incoming human immunodeficiency virus (HIV) virions in Birbeck granules for degradation.5,6 However, langerin was never viewed as a contributor to the interferon-mediated antiviral immune response. We now provide evidence that langerin is an ISG showing upregulated expression upon IFN treatment in monocyte-derived and ex vivo human skin-isolated LCs

    Hollow silicon microneedle fabrication using advanced plasma etch technologies for applications in transdermal drug delivery

    Get PDF
    A novel production process flow is presented here for the manufacture of hollow silicon microneedles using deep reactive-ion etching (DRIE) technology. The patent-pending three-step process flow has been developed to produce multiple arrays of sharp-tipped, hollow microneedles, which facilitate easy insertion and controlled fluid injection into excised skin samples. A bevelled tip and vertical sidewalls for the microneedle have been achieved with good uniformity, despite >45% open etch area. Processing steps and etch challenges are discussed, and preliminary skin testing results are presented, showing effective needle insertion and delivery of fluorescent dye into ex vivo skin from human breast tissue

    An analysis of the relationship between microneedle spacing, needle force and skin strain during the indentation phase prior to skin penetration

    Get PDF
    Microneedle (MN) array patches present a promising new approach for the minimally invasive delivery of therapeutics and vaccines. However, ensuring reproducible insertion of MNs into the skin is challenging. The spacing and arrangement of MNs in an array are critical determinants of skin penetration and the mechanical integrity of the MNs. In this work, the finite element method was used to model the effect of MN spacing on needle reaction force and skin strain during the indentation phase prior to skin penetration. Spacings smaller than 2–3 mm (depending on variables, e.g., skin stretch) were found to significantly increase these parameters

    TGFβ induces a SAMHD1-independent post-entry restriction to HIV-1 infection of human epithelial Langerhans cells

    Get PDF
    Sterile alpha motif (SAM) and histidine-aspartic (HD) domains protein 1 (SAMHD1) was previously identified as a critical post-entry restriction factor to HIV-1 infection in myeloid dendritic cells. Here we show that SAMHD1 is also expressed in epidermis-isolated Langerhans cells (LC), but degradation of SAMHD1 does not rescue HIV-1 or vesicular stomatitis virus G-pseudotyped lentivectors infection in LC. Strikingly, using Langerhans cells model systems (mutz-3-derived LC, monocyte-derived LC [MDLC], and freshly isolated epidermal LC), we characterize previously unreported post-entry restriction activity to HIV-1 in these cells, which acts at HIV-1 reverse transcription, but remains independent of restriction factors SAMHD1 and myxovirus resistance 2 (MX2). We demonstrate that transforming growth factor-β signaling confers this potent HIV-1 restriction in MDLC during their differentiation and blocking of mothers against decapentaplegic homolog 2 (SMAD2) signaling in MDLC restores cells’ infectivity. Interestingly, maturation of MDLC with a toll-like receptor 2 agonist or transforming growth factor-α significantly increases cells’ susceptibility to HIV-1 infection, which may explain why HIV-1 acquisition is increased during coinfection with sexually transmitted infections. In conclusion, we report a SAMHD1-independent post-entry restriction in MDLC and LC isolated from epidermis, which inhibits HIV-1 replication. A better understanding of HIV-1 restriction and propagation from LC to CD4+ T cells may help in the development of new microbicides or vaccines to curb HIV-1 infection at its earliest stages during mucosal transmission

    Design, fabrication, and characterisation of a silicon microneedle array for transdermal therapeutic delivery using a single step wet etch process

    Get PDF
    The fabrication of silicon in-plane microneedle arrays from a simple single wet etch step is presented. The characteristic 54.7° sidewall etch angle obtained via KOH etching of (1 0 0) orientation silicon wafers has been used to create a novel microneedle design. The KOH simultaneously etches both the front and back sides of the wafer to produce V shaped grooves, that intersect to form a sharp pyramidal six-sided microneedle tip. This method allows fabrication of solid microneedles with different geometries to determine the optimal microneedle length and width for effective penetration and minimally invasive drug delivery. A modified grooved microneedle design can also be used to create a hollow microneedle, via bonding of two grooved microneedles together, creating an enclosed hollow channel. The microneedle arrays developed, effectively penetrate the skin without significant indentation, thereby enabling effective delivery of active ingredients via either a poke and patch application using solid microneedles or direct injection using hollow microneedles. This simple, scalable and cost effective method utilises KOH to etch the silicon wafer in-plane, allowing microneedles with variable length of several mm to be fabricated, as opposed to out-of-plane MNs, which are geometrically restricted to dimensions less than the thickness of the wafer. These microneedle arrays have been used to demonstrate effective delivery of insulin and hyaluronic acid into the skin
    • …