66 research outputs found

    Left Ventricular Longitudinal Function Assessed by Speckle Tracking Ultrasound from a Single Apical Imaging Plane

    Get PDF
    Background. Transthoracic ultrasonography of the heart is valuable in monitoring and treatment of critically ill patients. Speckle tracking ultrasound (STU) has proven valid in estimating left ventricular systolic deformation. The aims of the study were to compare conventional and automated STU and to determine whether left ventricular systolic deformation could be estimated from one single imaging plane. Methods. 2D-echocardiography cine-loops were obtained from 20 patients for off-line speckle tracking analysis, consisting of manually tracing of the endocardial border (conventional method) or automatically drawn boundaries (automated method). Results. We found a bias of 0,6 (95% CI −2.2−3.3) for global peak systolic strain comparing the automated and the conventional method. Comparing global peak systolic strain of apical 4-chamber cine-loops with averaged Global Peak Strain obtained from apical 4, 2 and long axis cine-loops, showed a bias of 0.1 (95% CI −3.9−4.0). The agreement between subcostal 4-chamber and apical 4-chamber global peak systolic strain was 4.4 (95% CI −3.7−12.5). Conclusion. We found good agreement between the conventional and the automated method. STU applied to single apical 4-chamber cine-loops is in excellent agreement with overall averaged global peak systolic strain, while subcostal 4-chamber cine-loops proved less compliant with speckle tracking ultrasound

    Intraoperative milrinone versus dobutamine in cardiac surgery patients:a retrospective cohort study on mortality

    Get PDF
    Abstract Background Several choices of inotropic therapy are available and used in relation to cardiac surgery. Comparisons are necessary to select optimal therapy. In Denmark, dobutamine and milrinone are the two inotropic agents most commonly used to treat post-bypass low cardiac output syndrome. This study compares all-cause mortality with these drugs. Methods In a retrospective observational study we investigated 10,700 consecutive patients undergoing cardiac surgery from 1 April 2006 to 31 December 2013 at Aarhus and Aalborg University Hospitals in the Central and Northern Denmark Region. Prospectively entered data in the Western Danish Heart Registry on intraoperative use of inotropes were used to identify 952 patients treated with milrinone, 418 patients treated with dobutamine, and 82 patients receiving a combination of the two inotropes. All-cause mortality among patients receiving dobutamine was compared to all-cause mortality among milrinone receivers. Multiple logistic regression analyses including preoperative and intraoperative variables along with g-formula analyses were used to model 30-day and 1-year mortality risks. Reported were standardized mortality risk differences between the treatment groups. Results Among patients receiving intraoperative dobutamine, 18 (4.3%) died within 30 days and 49 (11.7%) within 1 year. Corresponding 30-day and 1-year mortality for milrinone receivers were 81 (8.5%) and 170 (17.9%). Risk of death within 30 days and 1 year was increased for intraoperative milrinone compared to dobutamine with a standardized risk difference of 4.06% (confidence interval (CI) 1.23; 6.89, p = 0.005) and 4.77% (CI 0.39; 9.15, p = 0.033), respectively. Sensitivity analyses including adjustment for milrinone preference, hemodynamic instability prior to cardiopulmonary bypass, and separate analyses on hospital level all confirmed a sign toward increased mortality among milrinone receivers. Conclusions Intraoperative use of milrinone in cardiac surgery may be associated with an increase in all-cause mortality compared to use of dobutamine

    Clinical Study Echocardiographic Measures of Diastolic Function Are Preload Dependent during Triggered Positive Pressure Ventilation: A Controlled Crossover Study in Healthy Subjects

    Get PDF
    Background. The use of echocardiography in intensive care settings impacts decision making. A prerequisite for the use of echocardiography is relative resistance to changes in volume status and levels of positive pressure ventilation (PPV). Studies on indices of diastolic function report conflicting results with regard to dependence on volume status. Evidence is scarce on PPV. Methods. Ten healthy subjects were exposed to 6 levels of positive end-expiratory pressure (PEEP) and pressure support (PS) following a baseline reading. All ventilator settings were performed at three positions: horizontal, reverse-Trendelenburg, and Trendelenburg. Echocardiography was performed throughout. Results. During spontaneous breathing, early diastolic transmitral velocity (E) changed with positioning (P < 0.001), whereas early diastolic velocity of the mitral annulus (e ) was independent (P = 0.263). With PPV, E and e proved preload dependent (P values < 0.001). Increases in PEEP, PS, or a combination influenced E and e in reverse-Trendelenburg-and horizontal positions, but not in the Trendelenburg position. Discussion. The change towards preload dependency of e with PPV suggests that PPV increases myocardial preload sensitivity. The susceptibility of E and e to preload changes during PPV discourages their use in settings of volume shifts or during changes in ventilator settings. Conclusion. Positioning and PPV affect E and e

    Statin initiation and acute kidney injury following elective cardiovascular surgery: a population cohort study in Denmark

    Get PDF
    OBJECTIVES: Acute kidney injury (AKI) is a serious complication of cardiac surgery. Statins may prevent post-surgical AKI, yet methodological concerns about existing studies raise questions about the magnitude of a protective effect. We sought to determine the effect of initiating a statin prior to elective cardiac surgery on post-surgical AKI in a regional Danish surgical cohort. METHODS: We identified adults who underwent cardiac surgery during 2006-11 using the Western Denmark Heart Registry. Presurgical medication use, pre- and post-surgical serum creatinine (sCr) measures, and other patient characteristics were obtained from Danish population-based registries. Post-surgical AKI was assessed using sCr measures within 5 days of surgery. The adjusted risk ratio (RR) of AKI and 95% confidence interval (CI) were estimated for patients who initiated a statin within 100 days prior to surgery compared with patients without prior statin use; long-term statin users were excluded to reduce healthy-user bias. Subanalyses were stratified by surgery type: coronary artery bypass grafting (CABG) and non-CABG surgeries. RESULTS: We identified 1929 CABG and 1775 non-CABG patients. AKI occurred in 25% of CABG and 28% of non-CABG surgeries, and in 29% of the non-users and 21% of the statin initiators. Half of CABG patients and 9% of non-CABG patients initiated a statin prior to surgery. The adjusted RRs for the effect of statin initiation on AKI were as follows: all surgeries combined, RR = 0.86 (95% CI: 0.74, 0.98); CABG, RR = 0.88 (0.74, 1.05); non-CABG RR = 0.87 (0.68, 1.11). CONCLUSIONS: Presurgical statin initiation is associated with a reduction in AKI risk after cardiac surgery

    ATLAS Run 1 searches for direct pair production of third-generation squarks at the Large Hadron Collider

    Get PDF

    Existing data sources for clinical epidemiology: The Western Denmark Heart Registry

    No full text
    Morten Schmidt1, Michael Maeng2, Carl-Johan Jakobsen3, Morten Madsen1, Leif Thuesen2, Per Hostrup Nielsen4, Hans Erik Bøtker2, Henrik Toft Sørensen11Department of Clinical Epidemiology, 2Department of Cardiology, 3Department of Anesthesia and Intensive Care, 4Department of Cardiothoracic Surgery, Aarhus University Hospital-Skejby, DenmarkBackground: The Western Denmark Heart Registry (WDHR) has not previously been described as a research tool in clinical epidemiology.Objectives: We examined the setting, organization, content, data quality, and research potential of the WDHR.Method: We collected information from members of the WDHR organization, including the committee of representatives, the board, the data management group, and physicians reporting to the database. We retrieved 2008 data from the WDHR to illustrate database variables.Results: The WDHR is a clinical database within a population-based health care system. It was launched on 1 January 1999 to monitor and improve the quality of cardiac intervention in Western Denmark (population: 3.3 million) and to allow for clinical and health-service research. More than 200,000 interventions, with 50–150 variables each, have been registered. The data quality is ensured by automatic validation rules at data entry combined with systematic validation procedures and random spot-checks after entry.Conclusions: The WDHR is a valuable research tool because it provides ongoing longitudinal registration of detailed patient and procedural data. The Danish national health care system enables this research because it allows complete follow-up for medical events after cardiac intervention by linkage with multiple medical databases.Keywords: cardiac surgical procedures, catheterization, coronary angiography, database, epidemiology, registrie

    Echocardiographic Measures of Diastolic Function Are Preload Dependent during Triggered Positive Pressure Ventilation: A Controlled Crossover Study in Healthy Subjects

    Get PDF
    Background. The use of echocardiography in intensive care settings impacts decision making. A prerequisite for the use of echocardiography is relative resistance to changes in volume status and levels of positive pressure ventilation (PPV). Studies on indices of diastolic function report conflicting results with regard to dependence on volume status. Evidence is scarce on PPV. Methods. Ten healthy subjects were exposed to 6 levels of positive end-expiratory pressure (PEEP) and pressure support (PS) following a baseline reading. All ventilator settings were performed at three positions: horizontal, reverse-Trendelenburg, and Trendelenburg. Echocardiography was performed throughout. Results. During spontaneous breathing, early diastolic transmitral velocity () changed with positioning (), whereas early diastolic velocity of the mitral annulus () was independent (). With PPV, and proved preload dependent (). Increases in PEEP, PS, or a combination influenced and in reverse-Trendelenburg- and horizontal positions, but not in the Trendelenburg position. Discussion. The change towards preload dependency of with PPV suggests that PPV increases myocardial preload sensitivity. The susceptibility of and to preload changes during PPV discourages their use in settings of volume shifts or during changes in ventilator settings. Conclusion. Positioning and PPV affect and
    corecore