38 research outputs found

    The Effects of Mechanical Stress on the Growth, Differentiation, and Paracrine Factor Production of Cardiac Stem Cells

    Get PDF
    Stem cell therapies have been clinically employed to repair the injured heart, and cardiac stem cells are thought to be one of the most potent stem cell candidates. The beating heart is characterized by dynamic mechanical stresses, which may have a significant impact on stem cell therapy. The purpose of this study is to investigate how mechanical stress affects the growth and differentiation of cardiac stem cells and their release of paracrine factors. In this study, human cardiac stem cells were seeded in a silicon chamber and mechanical stress was then induced by cyclic stretch stimulation (60 cycles/min with 120% elongation). Cells grown in non-stretched silicon chambers were used as controls. Our result revealed that mechanical stretching significantly reduced the total number of surviving cells, decreased Ki-67-positive cells, and increased TUNEL-positive cells in the stretched group 24 hrs after stretching, as compared to the control group. Interestingly, mechanical stretching significantly increased the release of the inflammatory cytokines IL-6 and IL-1β as well as the angiogenic growth factors VEGF and bFGF from the cells in 12 hrs. Furthermore, mechanical stretching significantly reduced the percentage of c-kit-positive stem cells, but increased the expressions of cardiac troponin-I and smooth muscle actin in cells 3 days after stretching. Using a traditional stretching model, we demonstrated that mechanical stress suppressed the growth and proliferation of cardiac stem cells, enhanced their release of inflammatory cytokines and angiogenic factors, and improved their myogenic differentiation. The development of this in vitro approach may help elucidate the complex mechanisms of stem cell therapy for heart failure

    Measurements of Elastic Moduli of Silicone Gel Substrates with a Microfluidic Device

    Get PDF
    Thin layers of gels with mechanical properties mimicking animal tissues are widely used to study the rigidity sensing of adherent animal cells and to measure forces applied by cells to their substrate with traction force microscopy. The gels are usually based on polyacrylamide and their elastic modulus is measured with an atomic force microscope (AFM). Here we present a simple microfluidic device that generates high shear stresses in a laminar flow above a gel-coated substrate and apply the device to gels with elastic moduli in a range from 0.4 to 300 kPa that are all prepared by mixing two components of a transparent commercial silicone Sylgard 184. The elastic modulus is measured by tracking beads on the gel surface under a wide-field fluorescence microscope without any other specialized equipment. The measurements have small and simple to estimate errors and their results are confirmed by conventional tensile tests. A master curve is obtained relating the mixing ratios of the two components of Sylgard 184 with the resulting elastic moduli of the gels. The rigidity of the silicone gels is less susceptible to effects from drying, swelling, and aging than polyacrylamide gels and can be easily coated with fluorescent tracer particles and with molecules promoting cellular adhesion. This work can lead to broader use of silicone gels in the cell biology laboratory and to improved repeatability and accuracy of cell traction force microscopy and rigidity sensing experiments

    Stabilising selection on immune response in male black grouse Lyrurus tetrix

    Get PDF
    Illnesses caused by a variety of micro- and macro- organisms can negatively affect individuals’ fitness, leading to the expectation that immunity is under positive selection. However, immune responses are costly and individuals must trade-off their immune response with other fitness components (e.g. survival or reproductive success) meaning that individuals with intermediate response may have the greatest overall fitness. Such a process might be particularly acute in species with strong sexual selection because the condition-dependence of male secondary sexual-traits might lead to striking phenotypic differences amongst males of different immune response levels. We tested whether there is selection on immune response by survival and reproduction in yearling and adult male black grouse (Lyrurus tetrix) following an immune challenge with a novel antigen and tested the hypothesis that sexual signals and body mass are honest signals of the immune response. We show that yearling males with highest immune response to these challenges had higher survival, but the reverse was true for adults. Adults with higher responses had highest mass loss and adult males with intermediate immune response had highest mating success. Tail length was related to baseline response in adults and more weakly in yearlings. Our findings reveal the complex fitness consequences of mounting an immune response across age classes. Such major differences in the direction and magnitude of selection in multiple fitness components is an alternative route underpinning the stabilizing selection of immune responses with an intermediate immune response being optimal

    A next-generation liquid xenon observatory for dark matter and neutrino physics

    Get PDF
    The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for weakly interacting massive particles, while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neutrinos through neutrinoless double-beta decay and through a variety of astrophysical sources. A next-generation xenon-based detector will therefore be a true multi-purpose observatory to significantly advance particle physics, nuclear physics, astrophysics, solar physics, and cosmology. This review article presents the science cases for such a detector
    corecore