22 research outputs found

    New Scores for the Assessment of Mitral Stenosis Using Real-Time Three-Dimensional Echocardiography

    Get PDF
    Nonsurgical management of patients with symptomatic mitral valve stenosis has been established as the therapeutic modality of choice for two decades. Catheter-based balloon dilation of the stenotic valvular area has been shown, at least, as effective as surgical interventions. Unfavorable results of catheter-based interventions are largely due to unfavorable morphology of the valve apparatus, particularly leaflets calcification and subvalvular apparatus involvement. A mitral valve score has been proposed in Boston, MA, about two decades ago, based on morphologic assessment of mitral valve apparatus by two-dimensional (2D) echocardiography to predict successful balloon dilation of the mitral valve. Several other scores have been developed in the following years in order to more successfully predict balloon dilatation outcome. However, all those scores were based on 2D echocardiography, which is limited by ability to distinguish calcification and subvalvular involvement. The introduction of new matrix-based ultrasound probe has allowed 3D echocardiography (3DE) to provide more detailed morphologic analysis of mitral valve apparatus including calcification and subvalvular involvement. Recently, a new 3DE scoring system has been proposed by our group, which represents an important leap into refinement of the use of echocardiography guiding mitral valve interventions

    Validation of Real-time Transthoracic 3D echocardiography in Children with Congenital Heart Disease

    Get PDF
    Aims: Assessment of feasibility, accuracy and applicability in clinical practice of real-time three-dimensional echocardiography (RT-3DE) in children with congenital heart defects. Methods and results: From September 2004 to June 2005, 100 consecutive children (57 infants, 43 children > 1 year of age), who were scheduled for corrective intracardiac surgery, were enrolled in this study. RT-3DE was performed with Philips Sonos 7500 echo-system and off-line analysis with TomTec Echoview© software. Quantitative and qualitative assessments of the region of interest were performed on the 3D reconstruction, comparing these results with the anatomic findings and measurements performed during intracardiac surgery. Acquisition of RT-3DE datasets was feasible in 92 of the 100 (92%) patients and acquisition time was 6 ± 3 minutes. The overall quantitative analyses showed an excellent correlation (r < 0.90) between RT-3De and surgery. Also the qualitative analyses were accurate compared with surgical findings, in all patients in which RT-3DE was feasible. Conclusion: This study shows that RT-3DE can be used in the clinical practice for the assessment of intracardiac anatomy in children with congenital heart disease. The information derived from the 3D reconstructions can be taken into consideration in the preoperative planning and management regarding interventional or surgical therapy

    Comparison of advanced echocardiographic right ventricular functional parameters with cardiovascular magnetic resonance in adult congenital heart disease

    Get PDF
    AimsAdvanced transthoracic echocardiography (TTE) using volumetric and deformational indices provides detailed quantification of right ventricular (RV) function in adults with congenital heart disease (ACHD). Two-dimensional multi-plane echocardiography (2D-MPE) has demonstrated regional wall differences in RV longitudinal strain (LS). This study aims to evaluate the association of these parameters with cardiovascular magnetic resonance (CMR).Methods and resultsOne hundred stable ACHD patients with primarily affected RVs were included (age 50±5 years; 53% male). Conventional and advanced echocardiographic RV functional parameters were compared to CMR-derived RV function.Advanced echocardiographic RV functional parameters were measurable in approximately one-half of the study co-hort, whilst multi-wall LS assessment feasibility was lower. CMR RV ejection fraction (CMR-RVEF) was moderately correlated with deformational, area and volumetric parameters (RV global LS [lateral wall and septum], n=55: r=-0.62, p<0.001; RV wall average LS, n=34: r=-0.49, p=0.002; RV lateral wall LS, n=56: r=-0.45, p<0.001; fractional area change [FAC], n=67: r=0.48, p<0.001; 3D-RVEF, n=48: r=0.40, p=0.005). Conventional measurements such as TAPSE and RV S’ correlated poorly. RV global LS best identified CMR-RVEF <45% (AUC: 0.84, p<0.001: cut-off value -19%: sensitivity 100%, specificity 57%). RVEF and LS values were significantly higher when measured by CMR compared to TTE (mean difference RVEF: 5[-9 to 18]%; lateral (free) wall LS: -7[7 to -21]%; RV global LS: -6 [5 to -16]%) whilst there was no association between respective LS values.ConclusionIn ACHD patients, advanced echocardiographic RV functional parameters are moderately correlated with CMR-RVEF, although significant differences exist between indices measurable by both modalities

    The role of experience in echocardiographic identification of location and extent of mitral valve prolapse with 2D and 3D echocardiography

    Get PDF
    Contradiction exists on the incremental value of two-dimensional (2D) and 3D transoesophageal echocardiography (TOE) over 2D transthoracic echocardiography (TTE) for the detection of mitral valve (MV) prolapse in readers with different echocardiographic experience. Twenty patients and five healthy persons were retrospectively identified who had undergone 2D-TTE, 2D-TOE and 3D-TOE. Fifteen (75 %) patients had surgical evidence of prolapse of the posterior MV leaflet and five patients (25 %) had a dilated MV annulus without prolapse. Three reader groups with different echocardiographic expertise (novice, trainees, cardiologists) scored thus in total 675 posterior scallops. Overall there was an improvement in agreement and Kappa values from novice to trainees to cardiologists. Diagnostic accuracies of 2D-TOE were higher than those of 2D-TTE mainly in novice readers. The incremental value of 3D-TOE over 2D-TOE was mainly seen in specificities. Time to diagnosis was dramatically reduced from 2D to 3D-TEE in all reader groups (all P < 0.001). 3D-TOE also improved the agreement (+12 to +16 %) and Kappa values (+0.14 to +0.21) in all reader groups for the exact description of P2 prolapse. Differences between readers with variable experience in determining the precise localization and extent of the prolapsing posterior MV scallops exist in particular in 2D-TTE analysis. 3D-TOE analysis was extremely fast compared to the 2D analysis methods and showed the best diagnostic accuracy (mainly driven by specificity) with identification of P1 and P3 prolapse still improving from novice to trainees to cardiologists and provided optimal description of P2 prolapse extent

    Dynamic 3D echocardiography in virtual reality

    Get PDF
    BACKGROUND: This pilot study was performed to evaluate whether virtual reality is applicable for three-dimensional echocardiography and if three-dimensional echocardiographic 'holograms' have the potential to become a clinically useful tool. METHODS: Three-dimensional echocardiographic data sets from 2 normal subjects and from 4 patients with a mitral valve pathological condition were included in the study. The three-dimensional data sets were acquired with the Philips Sonos 7500 echo-system and transferred to the BARCO (Barco N.V., Kortrijk, Belgium) I-space. Ten independent observers assessed the 6 three-dimensional data sets with and without mitral valve pathology. After 10 minutes' instruction in the I-Space, all of the observers could use the virtual pointer that is necessary to create cut planes in the hologram. RESULTS: The 10 independent observers correctly assessed the normal and pathological mitral valve in the holograms (analysis time approximately 10 minutes). CONCLUSION: this report shows that dynamic holographic imaging of three-dimensional echocardiographic data is feasible. However, the applicability and use-fullness of this technology in clinical practice is still limited

    Assessment of normal tricuspid valve anatomy in adults by real-time three-dimensional echocardiography

    Get PDF
    Background: The tricuspid valve (TV) is a complex structure. Unlike the aortic and mitral valve it is not possible to visualize all TV leaflets simultaneously in one cross-sectional view by standard two-dimensional echocardiography (2DE) either transthoracic or transesophageal due to the position of TV in the far field. Aim: Quantitative and qualitative assessment of the normal TV using real-time 3-dimensional echocardiography (RT3DE). Methods: RT3DE was performed for 100 normal adults (mean age 30 ± 9 years, 65% males). RT3DE visualization was evaluated by 4-point score (1: not visualized, 2: inadequate, 3: sufficient, and 4: excellent). Measurements included TV annulus diameters (TAD), TV area (TVA), and commissural width. Results: In 90% of patients with good 2DE image quality, it was possible to analyse TV anatomy by RT3DE. A detailed anatomical structure including unique description and measurement of tricuspid annulus shape and size, TV leaflets shape, and mobility, and TV commissural width were obtained in majority of patients. Identification of each TV leaflet as seen in the routine 2DE views was obtained. Conclusion: RT3DE of the TVis feasible in a large number of patients. RT3DE may add to functional 2DE data in description of TV anatomy and providing highly reproducible and actual reality (anatomical and functional) measurements
    corecore