2 research outputs found

    Clockwise torque results in higher reoperation rates in left-sided femur fractures

    No full text
    Purpose: Effects of clockwise torque rotation onto proximal femoral fracture fixation have been subject of ongoing debate: fixated right-sided trochanteric fractures seem more rotationally stable than left-sided fractures in the biomechanical setting, but this theoretical advantage has not been demonstrated in the clinical setting to date. The purpose of this study was to identify a difference in early reoperation rate between patients undergoing surgery for left- versus right-sided proximal femur fractures using cephalomedullary nailing (CMN). Materials and methods: The American College of Surgeons National Surgical Quality Improvement Program was queried from 2016-2019 to identify patients aged 50 years and older undergoing CMN for a proximal femoral fracture. The primary outcome was any unplanned reoperation within 30 days following surgery. The difference was calculated using a Chi-square test, and observed power calculated using post-hoc power analysis. Results: In total, of 20,122 patients undergoing CMN for proximal femoral fracture management, 1.8% (n=371) had to undergo an unplanned reoperation within 30 days after surgery. Overall, 208 (2.0%) were left-sided and 163 (1.7%) right-sided fractures (p=0.052, risk ratio [RR] 1.22, 95% confidence interval [CI] 1.00–1.50), odds ratio [OR] 1.23 (95%CI 1.00–1.51), power 49.2% (α=0.05). Conclusion: This study shows a higher risk of reoperation for left-sided compared to right-sided proximal femur fractures after CMN in a large sample size. Although results may be underpowered and statistically insignificant, this finding might substantiate the hypothesis that clockwise rotation during implant insertion and (postoperative) weightbearing may lead to higher reoperation rates. Level of evidence: Therapeutic level II.Information and Communication Technolog

    Management of displaced humeral surgical neck fractures in daily clinical practice: hanging does not re-align the fracture

    Get PDF
    Introduction: It is unclear if the collar and cuff treatment improve alignment in displaced surgical neck fractures of the proximal humerus. Therefore, this study evaluated if the neckshaft angle and extent of displacement would improve between trauma and onset of radiographically visible callus in non-operatively treated surgical neck fractures (Boileau type A, B, C). Materials and Methods: A consecutive series of patients (≥ 18 years old) were retrospectively evaluated from a level 1 trauma center in Australia (inclusion period: 2016–2020) and a level 2 trauma center in the Netherlands (inclusion period: 2004 to 2018). Patients were included if they sustained a Boileau-type fracture and underwent initial non-operative treatment. The first radiograph had to be obtained within 24 h after the initial injury and the follow-up radiograph(s) 1 week after trauma and before the start of radiographically visible callus. On each radiograph, the maximal medial gap (MMG), maximal lateral gap (MLG), and neck-shaft angle (NSA) were measured. Linear mixed modelling was performed to evaluate if these measurements would improve over time. Results: Sixty-seven patients were included: 25 type A, 11 type B, and 31 type C fractures. The mean age (range) was 68 years (24–93), and the mean number (range) of follow-up radiographs per patient was 1 (1–4). Linear mixed modelling on both MMG and MLG revealed no improvement during follow-up among the three groups. Mean NSA of type A fractures improved significantly from 161° at trauma to 152° at last follow-up (p-value = 0.004). Conclusions: Apart from humeral head angulation improvement in type A, there is no increase nor reduction in displacement among the three fracture patterns. Therefore, it is advised that surgical decision-making should be performed immediately after trauma. Level of clinical evidence: Level IV, retrospective case series.Biomechanical Engineerin
    corecore