7 research outputs found

    Pharmaceutical electrochemistry: the electrochemical detection of aspirin utilising screen printed graphene electrodes as sensors platforms.

    Get PDF
    A sensitive electrochemical sensor was designed for acetyl salicylic acid detection using graphene modified Screen Printed Electrodes. The electrochemical response of the sensor with graphene was improved compared to Screen Printed Electrodes without graphene and displayed an excellent analytical performance for the detection of acetyl salicylic acid. The high acetyl salicylic acid loading capacity on the electrode surface and the outstanding electric conductivity of graphene were also discussed in this manuscript. When a range of different concentrations of acetyl salicylic acid from 0.1 to 100 μM into a pH 4 buffer solution (N defined as the sample size N = 9) were plotted against the oxidation peak a linear response was observed. The detection limit was found to be 0.09 μM based on (3-σ/slope). Screen Printed Graphene electrodes sensors methodology is shown to be useful for quantifying low levels of acetyl salicylic acid in a buffer solution as well as in biological matrixes such as human oral fluid. A linear response was obtained over a range of concentrations from 10 to 150 μM into a human oral fluid solution (N = 10) giving a detection limit of 8.7 μM

    HPLC assay of acetylsalicylic acid, paracetamol, caffeine and phenobarbital in tablets

    No full text
    This paper present a HPLC method for simultaneous determination of acetylsalicylic acid, paracetamol, caffeine and phenobarbital in tablets, using chromatographic system consisting a Bio Rad 18 01 solvent pump, Rheodine 71 25 injector and Bio Rad 18 01 UV-Vis Detector. Separation was achieved using Bio SiL HL C 18, 5 mum, 250 x 4.6 mm column. Mixture of acetonitrile-water (25:75 v/v) adjusted to pH 2.5 with phosphoric acid was used as a mobile phase at a flow rate of 2.0 ml(-1) min UV detection was at 207 nm range 0.01 AUFS. Under the same conditions it was possible to determine the level of salicylic acid. The chromatographic parameters such as retention times, capacity factor, peak asymmetry, selectivity factor and resolution factor was determined. The validation parameters: linearity (r > 0.998), intra-day precision (RSD: 0.36-1.89%) and inter-day precision (RSD: 0.58-2.18%), sensitivity (LOD: 9 x 10(-5)-1.7 x 10(-4) mg ml(-1) and LOQ: 2.5 x 10(-4)-5.6 x 10(-4) mg ml(-1)), accuracy (recoveries: 98.35-99.14%) and reproducibility (recovery values: 98.74-102.08% for acetylsalicylic acid, 99.93-102.11% for paracetamol, 98.25-102.12% for caffeine and 98.15-102.3% for phenobarbital) (RSD: 1.21-1.85%) were found to be satisfactory. The proposed HPLC method has been applied for the determination of acetylsalicylic acid, paracetamol, caffeine and phenobarbital in Malophenum tablets. The obtained RSD values were within 0.99-1.21%. The developed method is rapid and sensitive and therefore suitable for routine control of these drugs in dosage form

    Quantitative analysis of analgoantipyretics in dosage form using planar chromatography

    No full text
    In the therapy of pain of weaker genesis, frequently used drugs usually represent a mix of analgoantipyretics of different chemical structures, mostly derivatives of salicylic acid, pyrazolone and p-aminophenol as well as derivatives of propionic and acetylsalicylic acid. For the determination of these drugs, different chromatographic methods have been applied, mostly HPLC, due to the the lower polarity (pyrazolones derivatives) and thermolability, as well as nonvolatility of compounds investigated. TLC method, considering advantages which include simplicity, reasonable sensitivity, rapidity, excellent resolving power and low cost has been successfully explored for the determination of analgoantipyretic compounds, The aim of this work was to develop a simple and rapid HPTLC method for the determination of acetylsalicylic acid, paracetamol, caffeine and phenobarbitone in dosage form. The determination of analgoantipyretics were performed on pre-coated HPTLC silica gel plates (10 x 20 cm(2)) by development in the mobile phase dichlormethanethyl acetate-cyclohexane-isopropanol-0.1 M HCL formic acid (9:8:3:1.5:0.2:0.2 v/v/v/v/v/v). Migration distances (68.5 + 0.2 mm, 54.1 + 0.1 mm, 36.4 + 0.14 mtn and 85.9 + 0.11 mm for acetylsalicylic acid, paracetamol. caffeine and phenobarbitone, respectively) with low RSD values (0.13-0.39%) showed a satisfactory reproductivity of the chromatographic system. TLC scanner. was used for direct evaluation of the chromatograms in the reflectance/absorbance mode. Established calibration curves (r > 0.999), precision (0.3-1.02%) and detection limits, as well as recovery values (96.51 98.1%) were validated and found to be satisfactory. The method was found to be reproducible and convenient for the quantitative analysis of compounds investigated in their dosage forms
    corecore