25 research outputs found

    Design and Test of Mixed-flow Impellers II : Experimental Results, Impeller Model MFI-1A

    Get PDF
    An investigation was conducted to determine the performance characteristics of a mixed-flow impeller which was designed with special emphasis on the reduction or elimination of flow decelerations along wetted surfaces. The performance was investigated over a range of equivalent impeller speeds from 700 to 1600 feet per second and over a range of flow rates from maximum adiabatic temperature-rise efficiency, measured at 1-1/2 impeller diameters in a vaneless diffuser, at the design speed of 1400 feet per second were 4.00 and 0.83, respectively

    Design and Test of Mixed-flow Impellers IV : Experimental Results for Impeller Models MFI-1 and MFI-2 with Changes in Blade Height

    Get PDF
    Modifications A and B of impeller model MFI-1 and A, B, and C of impeller model MFI-2 were investigated experimentally in an attempt to determine what allowance in blade height should be made for boundary layer and viscous losses in an impeller designed for isentropic compressible flow. A gradual increase in blade height was arbitrarily made from inlet to outlet in anticipation of a gradual build-up of boundary layer. Apparently there was a rapid build-up of boundary layer near the inlet in the experimental case rather than a gradual one. Therefore, the proper allowance for boundary layer cannot be described from the data obtained. Decreasing the pressure gradient along the shroud by reducing the blade height allowance apparently did little to increase the overall efficiency. At the design speed of 1400 feet per second, the overall adiabatic efficiency was increased from 0.83 for the MFI-1A to 0.85 for the MFI-1B with reduction in height; however, it is indicated from the theoretical velocity distribution and outlet surveys that the increase was due to a change from decelerating to accelerating flow along the hub rather than from any change along the shroud. It is further indicated that the consequences of a thickened or separated boundary layer depend not only on the design velocity gradients but also on the shape of the passage

    Evaluation of centrifugal compressor performance with water injection

    Get PDF
    The effects of water injection on a compressor are presented. To determine the effects of varying water-air ratio, the compressor was operated at a constant equivalent impeller speed over a range of water-air ratios and weight flows. Operation over a range of weight flows at one water-air ratio and two inlet air temperatures was carried out to obtain an indication of the effects of varying inlet air temperature. Beyond a water-air ratio of 0.03 there was no increase in maximum air-weight flow, a negligible rise in peak total-pressure ratio, and a decrease in peak adiabatic efficiency. An increase in inlet air temperature resulted in an increase in the magnitude of evaporation. An analysis of data indicated that the magnitude of evaporation within the compressor impeller was small

    Calibration of Air-Flow Meters for J33 Compressor Investigation

    No full text
    Flow-metering devices used by the NACA and by the manufacturer of the J33 turbojet engine were calibrated together to determine whether an observed discrepancy in weight flow of approximately 4 percent for the two separate investigations might be due to the different devices used to meter air flow. A commercial adjustable orifice and a square-edge flat-plate orifice used by the NACA and a flow nozzle used by the manufacturer were calibrated against surveys across the throat of the nozzle. It was determined that over a range of weight flows from 18 to 45 pounds per second the average weight flows measured by the metering device used for the compressor test would be 0.70 percent lower than those measured by the metering device used in the engine tests and the probable variation about this mean would be +/- 0.39 percent. The very close agreement of the metering devices shows that the greater part of the discrepancy in weight flow is attributable to the effect of inlet pressure

    Performance of Allison Model 400-C6 Turbojet-Engine Compressor

    No full text
    The Allison model 400-C6 compressor was operated at an inlet pressure of 12 inches of mercury absolute ana ambient inlet temperature at equivalent impeller speeds of 6000, 7000, and 8500 rpm. Additional runs at an equivalent speed of 7000 rpm and ambient inlet temperature were made at inlet pressures from 7 to 22 inches of mercury absolute. The results of this investigation are compared with those of the 533-A-23 compressors. For the speeds investigated, the Allison model 400-C6 compressor had a maximum adiabatic temperature-rise efficiency of 0.768 at an equivalent speed of 7000 rpm; the corresponding equivalent weight flow was 45.0 pounds per second and the pressure ratio was 1.83. At an equivalent impeller speed of 8500 rpm, the maximum equivalent weight flow was 61.6 pounds per second and the peak pressure ratio of 2.38 occurred at an equivalent weight flow of 52.2 pounds per 1 second and an adiabatic temperature-rise efficiency of 0.714. At an equivalent speed of 7000 rpm, increasing the compressor- inlet pressure increased the maximum equivalent weight flow and the pressure ratio

    Performance of J33-A-21 and J33-A-23 Turbojet-Engine Compressors with Water Injection

    No full text
    As part of the performance investigation of compressors for the J33 turbojet engine, the A-21 model and the A-23 model with a 17- and a 34-blade impeller were operated with water injection at their respective design equivalent speeds of 11,500 and 11,750 rpm. Inlet conditions of pressure of 14 inches of mercury absolute and of ambient temperature correspond to those of the investigation of these models without water injection. The water-air ratio by weight ranged from 0.05 to 0.06. By the use of water injection, the peak pressure ratio of the A-21 compressor and the A-23 compressor with a 34-blade impeller increased approximately 0.38, whereas that of the A-23 compressor with a 17-blade impeller increased only 0.14. The decrease in maximum efficiency for the three compressors ranged from 0.12 to 0.14. The highest increase in maximum equivalent weight flow of air plus weight flow of water was 10.90 pounds per second obtained with the A-21 compressor. The increase in air weight flow alone was approximately 5.70 pounds per second for the A-21 compressor end the A-23, 17-blade compressor, which exceeded the increase of 3.15 pounds per second for the A-23; 34-blade compressor
    corecore