5 research outputs found

    Electro-optic and radiation damage performance of the CIS115, an imaging sensor for the JANUS optical camera on-board JUICE

    Get PDF
    Copyright 2016 Society of Photo‑Optical Instrumentation Engineers (SPIE). One print or electronic copy may be made for personal use only. Systematic reproduction and distribution, duplication of any material in this publication for a fee or for commercial purposes, and modification of the contents of the publication are prohibited.The Jupiter Icy Moon Explorer (JUICE) has been officially adopted as the next Large class mission by the European Space Agency, with a launch date of 2022. The science payload includes an optical camera, JANUS, which will perform imaging and mapping observations of Jupiter, its moons and icy rings. A 13 slot filter wheel will be used to provide spectral information in order for the JANUS experiment to study the geology and physical properties of Ganymede, Europa and Io, and to investigate processes and structures in the atmosphere of Jupiter. The sensor selected for JANUS is the back-thinned CIS115, a 3 MPixel CMOS Image Sensor from e2v technologies. The CIS115 has a 4-Transistor pixel design with a pinned photodiode to improve signal to noise performance by reducing dark current and allowing for reset level subtraction. The JUICE mission will consist of an 8 year cruise phase followed by a 3 year science phase in the Jovian system. Models of the radiation environment throughout the JUICE mission predict that the End of Life (EOL) non-ionising damage will be equivalent to 1010 protons cm-2 (10 MeV) and the EOL ionising dose will be 100 krad(Si), once the shielding from the spacecraft and instrument design is taken into account. An extensive radiation campaign is therefore being carried out to qualify and characterise the CIS115 for JANUS, as well as other space and terrestrial applications. Radiation testing to take the CIS115 to twice the ionising dose and displacement damage levels was completed in 2015 and the change in sensor performance has been characterised. Good sensor performance has been observed following irradiation and a summary of the key results from the campaign using gamma irradiation (ionising dose) will be presented here, including its soft X-ray detection capabilities, flat-band voltage shift and readout noise. In 2016, further radiation campaigns on flight-representative CIS115s will be undertaken and their results will be disseminated in future publications

    Assessment of space proton radiation-induced charge transfer inefficiency in the CCD204 for the Euclid space observatory

    Get PDF
    Euclid is a medium class European Space Agency mission candidate for launch in 2019 with a primary goal to study the dark universe using the weak lensing and baryonic acoustic oscillations techniques. Weak lensing depends on accurate shape measurements of distant galaxies. Therefore it is beneficial that the effects of radiation-induced charge transfer inefficiency (CTI) in the Euclid CCDs over the course of the 5 year mission at L2 are understood. This will allow, through experimental analysis and modelling techniques, the effects of radiation induced CTI on shape to be decoupled from those of mass inhomogeneities along the line-of-sight. This paper discusses a selection of work from the study that has been undertaken using the e2v CCD204 as part of the initial proton radiation damage assessment for Euclid. The experimental arrangement and procedure are described followed by the results obtained, thereby allowing recommendations to be made on the CCD operating temperature, to provide an insight into CTI effects using an optical background, to assess the benefits of using charge injection on CTI recovery and the effect of the use of two different methods of serial clocking on serial CTI. This work will form the basis of a comparison with a p-channel CCD204 fabricated using the same mask set as the n-channel equivalent. A custom CCD has been designed, based on this work and discussions between e2v technologies plc. and the Euclid consortium, and designated the CCD273

    On-ground and in-orbit characterisation plan for the PLATO CCD normal cameras

    Get PDF
    PLAnetary Transits and Ocillations (PLATO) is the third European Space Agency (ESA) medium class mission in ESA’s cosmic vision programme due for launch in 2026. PLATO will carry out high precision un-interrupted photometric monitoring in the visible band of large samples of bright solar-type stars. The primary mission goal is to detect and characterise terrestrial exoplanets and their systems with emphasis on planets orbiting in the habitable zone, this will be achieved using light curves to detect planetary transits. PLATO uses a novel multi- instrument concept consisting of 26 small wide field cameras The 26 cameras are made up of a telescope optical unit, four Teledyne e2v CCD270s mounted on a focal plane array and connected to a set of Front End Electronics (FEE) which provide CCD control and readout. There are 2 fast cameras with high read-out cadence (2.5 s) for magnitude ∼ 4–8 stars, being developed by the German Aerospace Centre and 24 normal (N) cameras with a cadence of 25 s to monitor stars with a magnitude greater than 8. The N-FEEs are being developed at University College London’s Mullard Space Science Laboratory (MSSL) and will be characterised along with the associated CCDs. The CCDs and N-FEEs will undergo rigorous on-ground characterisation and the performance of the CCDs will continue to be monitored in-orbit. This paper discusses the initial development of the experimental arrangement, test procedures and current status of the N-FEE. The parameters explored will include gain, quantum efficiency, pixel response non-uniformity, dark current and Charge Transfer Inefficiency (CTI). The current in-orbit characterisation plan is also discussed which will enable the performance of the CCDs and their associated N-FEE to be monitored during the mission, this will include measurements of CTI giving an indication of the impact of radiation damage in the CCDs

    Initial proton damage comparison of an e2v technologies N-channel and P-channel CCD204

    No full text

    Vacancy-oxygen defects in silicon: the impact of isovalent doping

    No full text
    Silicon is the mainstream material for many nanoelectronic and photovoltaic applications. The understanding of oxygen related defects at a fundamental level is essential to further improve devices, as vacancy-oxygen defects can have a negative impact on the properties of silicon. In the present review we mainly focus on the influence of isovalent doping on the properties of A-centers in silicon. Wherever possible, we make comparisons with related materials such as silicon germanium alloys and germanium. Recent advanced density functional theory studies that provide further insights on the charge state of the A-centers and the impact of isovalent doping are also discussed in detail
    corecore