1,199 research outputs found

    Up in smoke: Considerations for lithium-ion batteries in disposable e-cigarettes

    Get PDF
    In recent years, the use of disposable electric (e)-cigarettes containing lithium-ion batteries in the UK has led to remarkable wastage, the full environmental impact of which is yet to be realized. This study investigates the suitability for reuse and safety aspects of cells found in disposable e-cigarettes. Through electrochemical and safety characterization techniques, the cells’ performance and hazards were evaluated. Rate capability and long-term cycling experiments showed that cells sold as disposable were capable of completing 474 cycles at 1C charge/discharge before reaching 80% capacity fade. A nail penetration test revealed significant gas expulsion and a maximum temperature of 495°C. However, the cell format prevented significant material ejection. This work outlines the potential health hazards and highlights the possibility for second-life use of disposable e-cigarette cells, shedding light on the environmental impact and safety considerations

    Electrochemical recovery of lithium-ion battery materials from molten salts by microstructural characterization using X-ray imaging

    Get PDF
    Recycling spent lithium-ion batteries (LiBs) guarantees the conservation of important metal resources by reducing demands on raw supply and offsetting the energy and environmental costs associated with its manufacture. Employing a molten salt as a solvent for extraction affords a much greener and simpler route to metal recovery by electrochemical means. The current mechanistic understanding of the electrochemical recovery of metals in molten salts needs to be improved for the process to be optimized. X-ray computed tomography offers a non-destructive approach for 3D microstructure visualization and subsequent quantification. Here, we study the electrochemical deposition of recovered cobalt metal from lithium cobalt oxide, LiCoO2 in LiCl-KCl eutectic (LKE). This diagnostic approach has been applied to LiCoO2-LKE samples before and after electrolysis at 450°C, yielding key insights into the morphological evolution of product formation

    Voluntary control of wearable robotic exoskeletons by patients with paresis via neuromechanical modeling.

    Get PDF
    BACKGROUND: Research efforts in neurorehabilitation technologies have been directed towards creating robotic exoskeletons to restore motor function in impaired individuals. However, despite advances in mechatronics and bioelectrical signal processing, current robotic exoskeletons have had only modest clinical impact. A major limitation is the inability to enable exoskeleton voluntary control in neurologically impaired individuals. This hinders the possibility of optimally inducing the activity-driven neuroplastic changes that are required for recovery. METHODS: We have developed a patient-specific computational model of the human musculoskeletal system controlled via neural surrogates, i.e., electromyography-derived neural activations to muscles. The electromyography-driven musculoskeletal model was synthesized into a human-machine interface (HMI) that enabled poststroke and incomplete spinal cord injury patients to voluntarily control multiple joints in a multifunctional robotic exoskeleton in real time. RESULTS: We demonstrated patients' control accuracy across a wide range of lower-extremity motor tasks. Remarkably, an increased level of exoskeleton assistance always resulted in a reduction in both amplitude and variability in muscle activations as well as in the mechanical moments required to perform a motor task. Since small discrepancies in onset time between human limb movement and that of the parallel exoskeleton would potentially increase human neuromuscular effort, these results demonstrate that the developed HMI precisely synchronizes the device actuation with residual voluntary muscle contraction capacity in neurologically impaired patients. CONCLUSIONS: Continuous voluntary control of robotic exoskeletons (i.e. event-free and task-independent) has never been demonstrated before in populations with paretic and spastic-like muscle activity, such as those investigated in this study. Our proposed methodology may open new avenues for harnessing residual neuromuscular function in neurologically impaired individuals via symbiotic wearable robots

    Nonuniform compensation of current density distribution in polymer electrolyte fuel cells by local heating

    Get PDF
    A homogeneous current density distribution improves a fuel cell’s performance and prolongs its service life. Effective cell structure designs and uniform compression during assembly could support this goal by ensuring a homogeneous reaction rate across the activation area. Due to the coupling of hydro-electro-thermal relationships, for instance, the concentration of reactants along the flow field decreases continuously as the electrochemical reaction proceeds, and the subsequent accumulation of liquid water leads to a low current density at the outlet. The effect of operating conditions, such as local heating, on the current density distribution requires further investigation. This paper studies the impact of local heating on polymer electrolyte fuel cell (PEFC) performance and analyses the effects on voltage by mapping the current density distribution across the active area. Local heating was supplied to the three regions of the electrode, namely, fuel inlet, central and outlet regions, with the latter exhibiting the best performance (in the activation, Ohmic and mass transport controlled region, the output voltage increases compared to no local heating corresponding to 1.28%, 2.17% and 2.46%, respectively). Here, we show that in all local heating cases, outlet heating can compensate for the lowest current density region with the largest current density increased by 91.10 mA cm−2 and achieves a more homogeneous current distribution, while inlet heating aggravates heterogeneity. This study provides practical guidance for optimal thermal management system development whereby the cooling channel design should be locally optimised for more uniform distributions of current density and temperature compared to heating the cell uniformly

    Nonuniform compensation of current density distribution in polymer electrolyte fuel cells by local heating

    Get PDF
    A homogeneous current density distribution improves a fuel cell's performance and prolongs its service life. Effective cell structure designs and uniform compression during assembly could support this goal by ensuring a homogeneous reaction rate across the activation area. Due to the coupling of hydro-electro-thermal relationships, for instance, the concentration of reactants along the flow field decreases continuously as the electrochemical reaction proceeds, and the subsequent accumulation of liquid water leads to a low current density at the outlet. The effect of operating conditions, such as local heating, on the current density distribution requires further investigation. This paper studies the impact of local heating on polymer electrolyte fuel cell (PEFC) performance and analyses the effects on voltage by mapping the current density distribution across the active area. Local heating was supplied to the three regions of the electrode, namely, fuel inlet, central and outlet regions, with the latter exhibiting the best performance (in the activation, Ohmic and mass transport controlled region, the output voltage increases compared to no local heating corresponding to 1.28%, 2.17% and 2.46%, respectively). Here, we show that in all local heating cases, outlet heating can compensate for the lowest current density region with the largest current density increased by 91.10 mA cm−2 and achieves a more homogeneous current distribution, while inlet heating aggravates heterogeneity. This study provides practical guidance for optimal thermal management system development whereby the cooling channel design should be locally optimised for more uniform distributions of current density and temperature compared to heating the cell uniformly

    Effects of an easy-to-implement water management strategy on performance and degradation of polymer electrolyte fuel cells

    Get PDF
    Intermittent switching between wet and dry reactant gases during operation in a polymer electrolyte fuel cell (PEFC) can improve performance stability, alleviating the effects of flooding by controlling the water content within the system. However, lifetime durability may be affected due to membrane electrode assembly (MEA) boundary delamination and membrane damage. Two relative humidity (RH) control strategies were investigated, using electrochemical performance and MEA degradation as critical indicators. It was found that intermittent switching between wet and dry gases does not accelerate fuel cell degradation if the duration of the dry gas period is set reasonably (dry gases stops before the voltage reaches the apex of the hump). Additionally, current and temperature distribution mapping was utilised to capture the dynamic response between these transitional stages. The switching of dry gases first makes the current density distribution homogeneous, and the maximum current density is reduced subsequently. Then, the current density near the inlet keeps decreasing. Intermittent switching between wet and dry reactant gases is easy to implement and overcomes limitations in mass transfer at medium and high current densities

    Implicaciones anestésicas en el Síndrome de Larsen: A propósito de un caso

    Get PDF
    Larsen Syndrome (SL) is a rare hereditary disease characterized by a defect in the formation of collagen due to mutations in the genes encoding the cytoskeletal protein filamin B. Its prevalence in Europe is approximately 1 to 250,000 live births. This implies a number of anatomical features of the airway that we must assess in children who are going under anesthesia. We present the case of an 11-year-old boy diagnosed with Larsen syndrome who underwent left ear aticotomy. In this regard, we conducted a literature review on the peculiarities of anesthetic management of these patients.  El síndrome de Larsen (SL) es una enfermedad hereditaria rara caracterizada por un defecto en la formación de colágeno debido a mutaciones en los genes que codifican la proteína citoesquelética filamina B. Su prevalencia en Europa es aproximadamente de 1/250.000 nacidos vivos. Esto implica una serie de rasgos y particularidades anatómicas de la vía aérea que debemos valorar en niños que van a ser sometidos a un acto anestésico. Se presenta el caso de un niño de 11 años diagnosticado de síndrome de Larsen que se interviene de aticotomía oído izquierdo. A este propósito, realizamos revisión bibliográfica sobre las peculiaridades del manejo anestésico de estos pacientes

    Risk factors for high anti-HHV-8 antibody titers (≥1:51,200) in black, HIV-1 negative South African cancer patients: a case control study

    Get PDF
    Background: Infection with human herpesvirus 8 (HHV-8) is the necessary causal agent in the development of Kaposi's sarcoma (KS). Infection with HIV-1, male gender and older age all increase risk for KS. However, the geographic distribution of HHV-8 and KS both prior to the HIV/AIDS epidemic and with HIV/AIDS suggest the presence of an additional co-factor in the development of KS. Methods: Between January 1994 and October 1997, we interviewed 2576 black in-patients with cancer in Johannesburg and Soweto, South Africa. Blood was tested for antibodies against HIV-1 and HHV-8 and the study was restricted to 2191 HIV-1 negative patients. Antibodies against the latent nuclear antigen of HHV-8 encoded by orf73 were detected with an indirect immunofluorescence assay. We examined the relationship between high anti-HHV-8 antibody titers (≥1:51,200) and sociodemographic and behavioral factors using unconditional logistic regression models. Variables that were significant at p = 0.10 were included in multivariate analysis. Results: Of the 2191 HIV-1 negative patients who did not have Kaposi's sarcoma, 854 (39.0%) were positive for antibodies against HHV-8 according to the immunofluorescent assay. Among those seropositive for HHV-8, 530 (62.1%) had low titers (1:200), 227 (26.6%) had medium titers (1:51,200) and 97 (11.4%) had highest titers (1:204,800). Among the 2191 HIV-1 negative patients, the prevalence of high anti-HHV-8 antibody titers (≥1:51,200) was independently associated with increasing age (ptrend = 0.04), having a marital status of separated or divorced (p = 0.003), using wood, coal or charcoal as fuel for cooking 20 years ago instead of electricity (p = 0.02) and consuming traditional maize beer more than one time a week (p = 0.02; p-trend for increasing consumption = 0.05) although this may be due to chance given the large number of predictors considered in this analysis. Conclusions: Among HIV-negative subjects, patients with high anti-HHV-8 antibody titers are characterized by older age. Other associations that may be factors in the development of high anti- HHV-8 titers include exposure to poverty or a low socioeconomic status environment and consumption of traditional maize beer. The relationship between these variables and high anti- HHV-8 titers requires further, prospective study

    Using an Indoor Localization System for Activity Recognition

    Get PDF
    Recognizing the activity performed by users is importantin many application domains, from e-health to home automation. Thispaper explores the use of a fine-grained indoor localization system, basedon ultra-wideband, for activity recognition. The user is supposed to weara number of active tags. The position of active tags is first determinedwith respect to the space where the user is moving, then some position-independent metrics are estimated and given as input to a previouslytrained system. Experimental results show that accuracy values as highas∼95% can be obtained when using a personalized model
    corecore