33 research outputs found

    Assessment of left ventricular volumes using simplified 3-D echocardiography and computed tomography – a phantom and clinical study

    Get PDF
    <p>Abstract</p> <p>Objectives</p> <p>To compare the accuracy of simplified 3-dimensional (3-D) echocardiography vs. multi-slice computed tomography (MSCT) software for the quantification of left ventricular (LV) volumes.</p> <p>Design</p> <p>Three-D echocardiography (3-planes approach) and MSCT-CardIQ software were calibrated by measuring known volumes of 10 phantoms designed to closely mimic blood-endocardium interface. Subsequently, LV volumes were measured with both the methods in 9 patients referred routinely for coronary angiography and the agreement between the measurements was evaluated.</p> <p>Results</p> <p>Simplified 3D-echocardiography provided higher degree of agreement between the measured and true phantom volumes (mean difference 0 ± 1 ml, variation range +4 to -4 ml) than MSCT software (mean difference 6 ± 5 ml; variation range +22 to -10 ml). The agreement between LV measurements in the patients was considerably poorer, with significantly larger volumes produced by MSCT (mean difference -23 ± 40 ml, variation between +93 and -138 ml).</p> <p>Conclusion</p> <p>Simplified 3-D echocardiography provides more accurate assessment of phantom volumes than MSCT-CardIQ software. The discrepancy between the results of LV measurements with the two methods is even greater and does not warrant their interchangeable diagnostic use.</p

    Flow-volume loops derived from three-dimensional echocardiography: a novel approach to the assessment of left ventricular hemodynamics

    Get PDF
    BACKGROUND: This study explores the feasibility of non-invasive evaluation of left ventricular (LV) flow-volume dynamics using 3-dimensional (3D) echocardiography, and the capacity of such an approach to identify altered LV hemodynamic states caused by valvular abnormalities. METHODS: Thirty-one patients with moderate-severe aortic (AS) and mitral (MS) stenoses (21 and 10 patients, respectively) and 10 healthy volunteers underwent 3D echocardiography with full volume acquisition using Philips Sonos 7500 equipment. The digital 3D data were post- processed using TomTec software. LV flow-volume loops were subsequently constructed for each subject by plotting instantaneous LV volume data sampled throughout the cardiac cycle vs. their first derivative representing LV flow. After correction for body surface area, an average flow-volume loop was calculated for each subject group. RESULTS: Flow-volume loops were obtainable in all subjects, except 3 patients with AS. The flow-volume diagrams displayed clear differences in the form and position of the loops between normal individuals and the respective patient groups. In patients with AS, an "obstructive" pattern was observed, with lower flow values during early systole and larger end-systolic volume. On the other hand, patients with MS displayed a "restrictive" flow-volume pattern, with reduced diastolic filling and smaller end-diastolic volume. CONCLUSION: Non-invasive evaluation of LV flow-volume dynamics using 3D-echocardiographic data is technically possible and the approach has a capacity to identify certain specific types of alteration of LV flow-volume pattern caused by valvular abnormalities, thus reflecting underlying hemodynamic states specific for these abnormalities

    Semi-automated quantification of left ventricular volumes and ejection fraction by real-time three-dimensional echocardiography

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Recent studies have shown that real-time three-dimensional (3D) echocardiography (RT3DE) gives more accurate and reproducible left ventricular (LV) volume and ejection fraction (EF) measurements than traditional two-dimensional methods. A new semi-automated tool (4DLVQ) for volume measurements in RT3DE has been developed. We sought to evaluate the accuracy and repeatability of this method compared to a 3D echo standard.</p> <p>Methods</p> <p>LV end-diastolic volumes (EDV), end-systolic volumes (ESV), and EF measured using 4DLVQ were compared with a commercially available semi-automated analysis tool (TomTec 4D LV-Analysis ver. 2.2) in 35 patients. Repeated measurements were performed to investigate inter- and intra-observer variability.</p> <p>Results</p> <p>Average analysis time of the new tool was 141s, significantly shorter than 261s using TomTec (<it>p </it>< 0.001). Bland Altman analysis revealed high agreement of measured EDV, ESV, and EF compared to TomTec (<it>p </it>= <it>NS</it>), with bias and 95% limits of agreement of 2.1 ± 21 ml, -0.88 ± 17 ml, and 1.6 ± 11% for EDV, ESV, and EF respectively. Intra-observer variability of 4DLVQ vs. TomTec was 7.5 ± 6.2 ml vs. 7.7 ± 7.3 ml for EDV, 5.5 ± 5.6 ml vs. 5.0 ± 5.9 ml for ESV, and 3.0 ± 2.7% vs. 2.1 ± 2.0% for EF (<it>p </it>= <it>NS</it>). The inter-observer variability of 4DLVQ vs. TomTec was 9.0 ± 5.9 ml vs. 17 ± 6.3 ml for EDV (<it>p </it>< 0.05), 5.0 ± 3.6 ml vs. 12 ± 7.7 ml for ESV (<it>p </it>< 0.05), and 2.7 ± 2.8% vs. 3.0 ± 2.1% for EF (<it>p </it>= <it>NS</it>).</p> <p>Conclusion</p> <p>In conclusion, the new analysis tool gives rapid and reproducible measurements of LV volumes and EF, with good agreement compared to another RT3DE volume quantification tool.</p

    Optical coherence tomography for guidance of distal cell recrossing in bifurcation stenting: Choosing the right cell matters

    No full text
    Aims: The aim of this study was to assess the ability of optical coherence tomography (OCT) to guide recrossing during percutaneous coronary interventions in bifurcations and to reduce strut malapposition. Methods and results: Fifty-two patients undergoing elective treatment of bifurcation lesions using provisional stenting as default strategy were included in the study. Patients were divided into two groups: OCT-guided stent recrossing (group 1, n=12), and angiography-guided recrossing (group 2, n=40). Malapposition in the various bifurcation segments was compared in the two groups, using propensity score analysis to correct for confounders. In 4/12 patients (33%) of the OCT-guided group after the first attempt to recross the stent towards the SB the wire was found to have crossed in a proximal cell, requiring a second and in one case a third attempt to successfully cross through a distal cell. Patients who were treated using OCT-guided recrossing had a significantly lower number of malapposed stent struts, especially in the quadrants towards the SB ostium (9.5%[7.5-17.4%] vs 42.3%[31.2-54.7%] in the angiography-guided group, p<0.0001). Conclusions: The rate of strut malapposition was significantly reduced when OCT was used to confirm that wire recrossing was performed in a distal cell of the SB ostium. © Europa Edition 2012. All rights reserved.link_to_subscribed_fulltex

    CTO and Bifurcation Lesions: An Expert Consensus From the European Bifurcation Club and EuroCTO Club.

    No full text
    Knowledge in the field of bifurcation lesions and chronic total occlusions (CTOs) has progressively improved over the past 20 years. Therefore, the European Bifurcation Club and the EuroCTO Club have decided to write a joint consensus statement to share general knowledge and practical approaches in this complex field. When percutaneously treating CTOs, bifurcation lesions with relevant side branches (SBs) are found in approximately one-third of cases (35% at the proximal cap, 38% at the distal cap, and 27% within the CTO body). Occlusion of a relevant SB is not rare and has been shown to be associated with procedural complications and adverse outcomes. Simple bifurcation rules are very useful to prevent SB occlusion, and provisional SB stenting is the recommended approach in the majority of cases: protect the SB as soon as possible by wiring it, respect the fractal anatomy of the bifurcation by using the 3-diameter rule, and avoid using dissection and re-entry techniques. A systematic 2-stent approach can be used if needed or sometimes to connect both branches of the bifurcation. The retrograde approach can be very useful to save a relevant SB, especially in the case of a bifurcation at the distal cap or within the CTO body. Intravascular ultrasound is also a very important tool to address the difficulties with bifurcations at the proximal or distal cap and sometimes also within the CTO segment. Double-lumen microcatheters and angulated microcatheters are crucial tools to resolve access difficulties to the SB or the main branch
    corecore