12 research outputs found

    Measuring the effect of enhanced cleaning in a UK hospital : a prospective cross-over study

    Get PDF
    Increasing hospital-acquired infections have generated much attention over the last decade. There is evidence that hygienic cleaning has a role in the control of hospital-acquired infections. This study aimed to evaluate the potential impact of one additional cleaner by using microbiological standards based on aerobic colony counts and the presence of Staphylococcus aureus including meticillin-resistant S. aureus. We introduced an additional cleaner into two matched wards from Monday to Friday, with each ward receiving enhanced cleaning for six months in a cross-over design. Ten hand-touch sites on both wards were screened weekly using standardised methods and patients were monitored for meticillin-resistant S. aureus infection throughout the year-long study. Patient and environmental meticillin-resistant S. aureus isolates were characterised using molecular methods in order to investigate temporal and clonal relationships. Enhanced cleaning was associated with a 32.5% reduction in levels of microbial contamination at handtouch sites when wards received enhanced cleaning (P < 0.0001: 95% CI 20.2%, 42.9%). Near-patient sites (lockers, overbed tables and beds) were more frequently contaminated with meticillin-resistant S. aureus/S. aureus than sites further from the patient (P = 0.065). Genotyping identified indistinguishable strains from both handtouch sites and patients. There was a 26.6% reduction in new meticillin-resistant S. aureus infections on the wards receiving extra cleaning, despite higher meticillin-resistant S. aureus patient-days and bed occupancy rates during enhanced cleaning periods (P = 0.032: 95% CI 7.7%, 92.3%). Adjusting for meticillin-resistant S. aureus patient-days and based upon nine new meticillin-resistant S. aureus infections seen during routine cleaning, we expected 13 new infections during enhanced cleaning periods rather than the four that actually occurred. Clusters of new meticillin-resistant S. aureus infections were identified 2 to 4 weeks after the cleaner left both wards. Enhanced cleaning saved the hospital £30,000 to £70,000.Introducing one extra cleaner produced a measurable effect on the clinical environment, with apparent benefit to patients regarding meticillin-resistant S. aureus infection. Molecular epidemiological methods supported the possibility that patients acquired meticillin-resistant S. aureus from environmental sources. These findings suggest that additional research is warranted to further clarify the environmental, clinical and economic impact of enhanced hygienic cleaning as a component in the control of hospital-acquired infection

    Acquired homotypic and heterotypic immunity against oculogenital Chlamydia trachomatis serovars following female genital tract infection in mice

    Get PDF
    BACKGROUND: Chlamydia trachomatis is the most common sexually transmitted bacterial pathogen causing female genital tract infection throughout the world. Reinfection with the same serovar, as well as multiple infections with different serovars, occurs in humans. Using a murine model of female C. trachomatis genital tract infection, we determined if homotypic and/or heterotypic protection against reinfection was induced following infection with human oculogenital strains of C. trachomatis belonging to two serovars (D and H) that have been shown to vary significantly in the course of infection in the murine model. METHODS: Groups of outbred CF-1 mice were reinfected intravaginally with a strain of either serovar D or H, two months after initial infection with these strains. Cellular immune and serologic status, both quantitative and qualitative, was assessed following initial infection, and the course of infection was monitored by culturing vaginal samples collected every 2–7 days following reinfection. RESULTS: Serovar D was both more virulent (longer duration of infection) and immunogenic (higher level of circulating and vaginal IgG and higher incidence of IgA in vaginal secretions) in the mouse genital tract. Although both serovars induced cross-reacting antibodies during the course of primary infection, prior infection with serovar H resulted in only a slight reduction in the median duration of infection against homotypic reinfection (p ~ 0.10), while prior infection with serovar D resulted in significant reduction in the median duration of infection against both homotypic (p < 0.01) and heterotypic reinfection (p < 0.01) when compared to primary infection in age and conditions matched controls. CONCLUSION: Serovar D infection resulted in significant homotypic and heterotypic protection against reinfection, while primary infection with serovar H resulted in only slight homotypic protection. In addition to being the first demonstration of acquired heterotypic immunity between human oculogenital serovars, the differences in the level and extent of this immunity could in part explain the stable difference in serovar prevalence among human isolates

    Are there regional variations in the diagnosis surveillance, and control of methicillin-resistant Staphylococcus aureus?

    No full text
    OBJECTIVE: To assess the way healthcare facilities (HCFs) diagnose, survey, and control methicillin-resistant Staphylococcus aureus (MRSA). DESIGN: Questionnaire. SETTING: Ninety HCFs in 30 countries. RESULTS: Evaluation of susceptibility testing methods showed that 8 laboratories (9%) used oxacillin disks with antimicrobial content different from the one recommended, 12 (13%) did not determine MRSA susceptibility to vancomycin, and 4 (4.5%) reported instances of isolation of vancomycin-resistant S. aureus but neither confirmed this resistance nor alerted public health authorities. A MRSA control program was reported by 55 (61.1%) of the HCFs. The following isolation precautions were routinely used: hospitalization in a private room (34.4%), wearing of gloves (62.2%), wearing of gowns (44.4%), hand washing by healthcare workers (53.3%), use of an isolation sign on the patient's door (43%), or all four. When the characteristics of HCFs with low incidence rates (< 0.4 per 1,000 patient-days) were compared with those of HCFs with high incidence rates (≥ 0.4 per 1,000 patient-days), having a higher mean number of beds per infection control nurse was the only factor significantly associated with HCFs with high incidence rates (834 vs 318 beds; P = .02). CONCLUSION: Our results emphasize the urgent need to strengthen the microbiologic and epidemiologic capacities of HCFs worldwide to prevent MRSA transmission and to prepare them to address the possible emergence of vancomycin-resistant S. aureus.link_to_subscribed_fulltex
    corecore