16 research outputs found

    Functional imaging using fluorine ((19)F) MR methods: basic concepts

    Get PDF
    Kidney-associated pathologies would greatly benefit from noninvasive and robust methods that can objectively quantify changes in renal function. In the past years there has been a growing incentive to develop new applications for fluorine ((19)F) MRI in biomedical research to study functional changes during disease states. (19)F MRI represents an instrumental tool for the quantification of exogenous (19)F substances in vivo. One of the major benefits of (19)F MRI is that fluorine in its organic form is absent in eukaryotic cells. Therefore, the introduction of exogenous (19)F signals in vivo will yield background-free images, thus providing highly selective detection with absolute specificity in vivo. Here we introduce the concept of (19)F MRI, describe existing challenges, especially those pertaining to signal sensitivity, and give an overview of preclinical applications to illustrate the utility and applicability of this technique for measuring renal function in animal models. This chapter is based upon work from the COST Action PARENCHIMA, a community-driven network funded by the European Cooperation in Science and Technology (COST) program of the European Union, which aims to improve the reproducibility and standardization of renal MRI biomarkers. This introduction chapter is complemented by two separate chapters describing the experimental procedure and data analysis

    Small stitches with small suture distances increase laparotomy closure strength

    No full text
    BACKGROUND: There is no conclusive evidence which size of suture stitches and suture distance should be used to prevent burst abdomen and incisional hernia. METHODS: Thirty-eight porcine abdominal walls were removed immediately after death and divided into 2 groups: A and B (N = 19 each). Two suturing methods using double-loop polydioxanone were tested in 14-cm midline incisions: group A consisted of large stitches (1 cm) with a large suture distance (1 cm), and group B consisted of small stitches (.5 cm) with a small suture distance (.5 cm). RESULTS: The geometric mean tensile force in group B was significantly higher than in group A (787 N vs 534 N; P = .006). CONCLUSIONS: Small stitches with small suture distances achieve higher tensile forces than large stitches with large suture distances. Therefore, small stitches may be useful to prevent the development of a burst abdomen or an incisional hernia after midline incisions. (C) 2009 Elsevier Inc. All rights reserved

    The use of mesh in acute hernia: frequency and outcome in 99 cases

    Get PDF
    Incarceration of inguinal, umbilical and cicatricial hernias is a frequent problem. However, little is known about the relationship between the use of mesh and outcome after surgery. The goal of this study was to describe the relationship between the use of mesh in incarcerated hernia and the clinical outcome. Correspondence, operation reports and patient files between January 1995 and December 2005 of patients presented at one academic and one teaching hospital in Rotterdam were searched for the following keywords: incarceration, strangulation and hernia. The patient characteristics, clinical presentation, pre-operative findings and clinical course were scored and analysed. A total of 203 patients could be identified: 76 inguinal, 52 umbilical, 39 incisional, 14 epigastric, 14 femoral, five trocar and three spigelian hernias. In the statistical analysis, epigastric, femoral, trocar and spigelian hernias were pooled, due to their small group sizes. One patient was excluded from the analysis because the hernia was not corrected during operation. In total, 99 hernias were repaired using mesh versus 103 primary suture repairs. Twenty-five wound infections were registered (12.3%). One mesh was removed during a reintervention for anastomotic leakage, although no signs of wound infection were present. Nine patients died, none of them due to wound-related problems [one cardiovascular, one ruptured aneurysm, two anastomotic leakage, two sepsis e causa incognita (e.c.i.), three pulmonary complications]. Univariate analysis showed that female patients (P = 0.007), adipose patients (P = 0.016), patients with an umbilical hernia (P = 0.01) and patients who underwent a bowel resection (P = 0.015) had a significantly higher rate of wound infections. The type of repair (e.g. primary suture or mesh), use of antibiotic prophylaxis, gender, ASA class and age showed no significant relation with post-operative wound infection. After logistic regression analysis, only bowel resection (P = 0.020) showed a significant relation with post-operative wound infection. Wound infection rates are high after the correction of acute hernia, but clinical consequences are relatively low. Mesh correction of an acute hernia seems to be safe and should be considered in every incarcerated hernia
    corecore