25 research outputs found

    Combined sedation with midazolam/propofol for gastrointestinal endoscopy in elderly patients

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Although gastrointestinal endoscopy with sedation is increasingly performed in elderly patients, data on combined sedation with midazolam/propofol are very limited for this age group.</p> <p>Methods</p> <p>We retrospectively analyzed 454 endoscopic procedures in 347 hospitalized patients ≥ 70 years who had received combined sedation with midazolam/propofol. 513 endoscopic procedures in 397 hospitalized patients < 70 years during the observation period served as controls. Characteristics of endoscopic procedures, co-morbidity, complications and mortality were compared.</p> <p>Results</p> <p>Elderly patients had a higher level of co-morbidity and needed lower mean propofol doses for sedation. We observed no major complication and no difference in the number of minor complications. The procedure-associated mortality was 0%; the 28-day mortality was significantly higher in the elderly (2.9% vs. 1.0%).</p> <p>Conclusions</p> <p>In this study on elderly patients with high level co-morbidity, a favourable safety profile was observed for a combined sedation with midazolam/propofol with a higher sensitivity to propofol in the elderly.</p

    Three lateral osteotomy designs for bilateral sagittal split osteotomy: biomechanical evaluation with three-dimensional finite element analysis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The location of the lateral osteotomy cut during bilateral sagittal split osteotomy (BSSO) varies according to the surgeon's preference, and no consensus has been reached regarding the ideal location from the perspective of biomechanics. The purpose of this study was to evaluate the mechanical behavior of the mandible and screw-miniplate system among three lateral osteotomy designs for BSSO by using three-dimensional (3-D) finite element analysis (FEA).</p> <p>Methods</p> <p>The Trauner-Obwegeser (TO), Obwegeser (Ob), and Obwegeser-Dal Pont (OD) methods were used for BSSO. In all the FEA simulations, the distal segments were advanced by 5 mm. Each model was fixed by using miniplates. These were applied at four different locations, including along Champy's lines, to give 12 different FEA miniplate fixation methods. We examined these models under two different loads.</p> <p>Results</p> <p>The magnitudes of tooth displacement, the maximum bone stress in the vicinity of the screws, and the maximum stress on the screw-miniplate system were less in the OD method than in the Ob and TO methods at all the miniplate locations. In addition, Champy's lines models were less than those at the other miniplate locations.</p> <p>Conclusions</p> <p>The OD method allows greater mechanical stability of the mandible than the other two techniques. Further, miniplates placed along Champy's lines provide greater mechanical advantage than those placed at other locations.</p

    Identification of Mechanosensitive Genes during Embryonic Bone Formation

    Get PDF
    Although it is known that mechanical forces are needed for normal bone development, the current understanding of how biophysical stimuli are interpreted by and integrated with genetic regulatory mechanisms is limited. Mechanical forces are thought to be mediated in cells by “mechanosensitive” genes, but it is a challenge to demonstrate that the genetic regulation of the biological system is dependant on particular mechanical forces in vivo. We propose a new means of selecting candidate mechanosensitive genes by comparing in vivo gene expression patterns with patterns of biophysical stimuli, computed using finite element analysis. In this study, finite element analyses of the avian embryonic limb were performed using anatomically realistic rudiment and muscle morphologies, and patterns of biophysical stimuli were compared with the expression patterns of four candidate mechanosensitive genes integral to bone development. The expression patterns of two genes, Collagen X (ColX) and Indian hedgehog (Ihh), were shown to colocalise with biophysical stimuli induced by embryonic muscle contractions, identifying them as potentially being involved in the mechanoregulation of bone formation. An altered mechanical environment was induced in the embryonic chick, where a neuromuscular blocking agent was administered in ovo to modify skeletal muscle contractions. Finite element analyses predicted dramatic changes in levels and patterns of biophysical stimuli, and a number of immobilised specimens exhibited differences in ColX and Ihh expression. The results obtained indicate that computationally derived patterns of biophysical stimuli can be used to inform a directed search for genes that may play a mechanoregulatory role in particular in vivo events or processes. Furthermore, the experimental data demonstrate that ColX and Ihh are involved in mechanoregulatory pathways and may be key mediators in translating information from the mechanical environment to the molecular regulation of bone formation in the embryo

    Consequences of Cold-Ischemia Time on Primary Nonfunction and Patient and Graft Survival in Liver Transplantation: A Meta-Analysis

    Get PDF
    Introduction: The ability to preserve organs prior to transplant is essential to the organ allocation process. Objective: The purpose of this study is to describe the functional relationship between cold-ischemia time (CIT) and primary nonfunction (PNF), patient and graft survival in liver transplant. Methods: To identify relevant articles Medline, EMBASE and the Cochrane database, including the non-English literature identified in these databases, was searched from 1966 to April 2008. Two independent reviewers screened and extracted the data. CIT was analyzed both as a continuous variable and stratified by clinically relevant intervals. Nondichotomous variables were weighted by sample size. Percent variables were weighted by the inverse of the binomial variance. Results: Twenty-six studies met criteria. Functionally, PNF%=-6.678281+0.9134701*CIT Mean+0.1250879*(CIT Mean-9.89535) 2 - 0.0067663*(CIT Mean-9.89535) 3, r2=.625, p<.0001. Mean patient survival: 93 % (1 month), 88 % (3 months), 83 % (6 months) and 83 % (12 months). Mean graft survival: 85.9 % (1 month), 80.5 % (3 months), 78.1 % (6 months) and 76.8 % (12 months). Maximum patient and graft survival occurred with CITs between 7.5-12.5 hrs at each survival interval. PNF was also significantly correlated with ICU time, % first time grafts and % immunologic mismatches. Conclusion: The results of this work imply that CIT may be the most important pre-transplant information needed in the decision to accept an organ. © 2008 Stahl et al

    The primary cilium as a dual sensor of mechanochemical signals in chondrocytes

    Get PDF
    The primary cilium is an immotile, solitary, and microtubule-based structure that projects from cell surfaces into the extracellular environment. The primary cilium functions as a dual sensor, as mechanosensors and chemosensors. The primary cilia coordinate several essential cell signaling pathways that are mainly involved in cell division and differentiation. A primary cilium malfunction can result in several human diseases. Mechanical loading is sense by mechanosensitive cells in nearly all tissues and organs. With this sensation, the mechanical signal is further transduced into biochemical signals involving pathways such as Akt, PKA, FAK, ERK, and MAPK. In this review, we focus on the fundamental functional and structural features of primary cilia in chondrocytes and chondrogenic cells
    corecore