32 research outputs found

    Effect of transverse gap-junction channels on transverse propagation in an enlarged PSpice model of cardiac muscle

    Get PDF
    BACKGROUND: In previous PSpice modeling studies of simulated action potentials (APs) in parallel chains of cardiac muscle, it was found that transverse propagation could occur between adjacent chains in the absence of gap-junction (gj) channels, presumably by the electric field (EF) generated in the narrow interstitial space between the chains. Transverse propagation was sometimes erratic, the more distal chains firing out of order. METHODS: In the present study, the propagation of complete APs was studied in a 2-dimensional network of 100 cardiac muscle cells (10 × 10 model). Various numbers of gj-channels (assumed to be 100 pS each) were inserted across the junctions between the longitudinal cells of each chain and between adjacent chains (only at the end cells of each chain). The shunt resistance produced by the gj-channels (R(gj)) was varied from 100,000 MΩ (0 gj-channels) to 1,000 MΩ (10 channels), 100 MΩ (100 channels) and 10 MΩ (1,000 channels). Total propagation time (TPT) was measured as the difference between the times when the AP rising phase of the first cell (cell # A1) and the last cell (in the J chain) crossed 0 mV. When there were no gj-channels, the excitation was transmitted between cells by the EF, i.e., the negative potential generated in the narrow junctional clefts (e.g., 100 Å) when the prejunctional membrane fired an AP. For the EF mechanism to work, the prejunctional membrane must fire a fraction of a millisecond before the adjacent surface membrane. When there were many gj-channels (e.g., 100 or 1,000), the excitation was transmitted by local-circuit current flow from one cell to the next through these channels. RESULTS: TPT was measured as a function of four different numbers of transverse gj-channels, namely 0, 10, 100 and 1,000, and four different numbers of longitudinal gj-channels, namely 0, 10, 100 and 1,000. Thus, 16 different measurements were made. It was found that increasing the number of transverse channels had no effect on TPT when the number of longitudinal channels was low (i.e., 0 or 10). In contrast, when the number of longitudinal gj-channels was high (e.g., 100 or 1,000), then increasing the number of transverse channels decreased TPT markedly. CONCLUSION: Thus, complete APs could propagate along a network of 100 cardiac muscle cells even when no gj-channels were present between the cells. Insertion of transverse gj-channels greatly speeded propagation through the 10 × 10 network when there were also many longitudinal gj-channels

    Global Dynamics of the MLT

    Full text link

    How to find and use validated blood pressure measuring devices

    No full text
    Clinically validated, automated arm-cuff blood pressure measuring devices (BPMDs) are recommended for BP measurement. However, most BPMDs available for purchase by consumers globally are not properly validated. This is a problem because non-validated BPMDs are less accurate and precise than validated ones, and therefore if used clinically could lead to misdiagnosis and mismanagement of BP. In response to this problem, several validated device lists have been developed, which can be used by clinicians and consumers to identify devices that have passed accuracy validation testing. The purpose of this review is to describe the resources that are available for finding validated BPMDs in different world regions, to identify the differences between validated device lists, and describe current gaps and challenges. How to use validated BPMDs properly is also summarised

    How to find and use validated blood pressure measuring devices

    No full text
    Clinically validated, automated arm-cuff blood pressure measuring devices (BPMDs) are recommended for BP measurement. However, most BPMDs available for purchase by consumers globally are not properly validated. This is a problem because non-validated BPMDs are less accurate and precise than validated ones, and therefore if used clinically could lead to misdiagnosis and mismanagement of BP. In response to this problem, several validated device lists have been developed, which can be used by clinicians and consumers to identify devices that have passed accuracy validation testing. The purpose of this review is to describe the resources that are available for finding validated BPMDs in different world regions, to identify the differences between validated device lists, and describe current gaps and challenges. How to use validated BPMDs properly is also summarised

    Gap-junction channels inhibit transverse propagation in cardiac muscle

    Get PDF
    <p>Abstract</p> <p>The effect of adding many gap-junctions (g-j) channels between contiguous cells in a linear chain on transverse propagation between parallel chains was examined in a 5 × 5 model (5 parallel chains of 5 cells each) for cardiac muscle. The action potential upstrokes were simulated using the PSpice program for circuit analysis. Either a single cell was stimulated (cell A1) or the entire chain was stimulated simultaneously (A-chain). Transverse velocity was calculated from the total propagation time (TPT) from when the first AP crossed a V<sub>m </sub>of -20 mV and the last AP crossed -20 mV. The number of g-j channels per junction was varied from zero to 100, 1,000 and 10,000 (R<sub>gj </sub>of ∞, 100 MΩ, 10 MΩ, 1.0 MΩ, respectively). The longitudinal resistance of the interstitial fluid (ISF) space between the parallel chains (R<sub>ol2</sub>) was varied between 200 KΩ (standard value) and 1.0, 5.0, and 10 MΩ. The higher the R<sub>ol2 </sub>value, the tighter the packing of the chains. It was found that adding many g-j channels inhibited transverse propagation by blocking activation of all 5 chains, unless R<sub>ol2 </sub>was greatly increased above the standard value of 200 KΩ. This was true for either method of stimulation. This was explained by, when there is strong longitudinal coupling between all 5 cells of a chain awaiting excitation, there must be more transfer energy (i.e., more current) to simultaneously excite all 5 cells of a chain.</p