25 research outputs found

    Impact of asymmetries on fuel performance in inertial confinement fusion

    Get PDF
    Low-mode asymmetries prevent effective compression, confinement, and heating of the fuel in inertial confinement fusion (ICF) implosions, and their control is essential to achieving ignition. Ion temperatures (Tion) in ICF experiments are inferred from the broadening of primary neutron spectra. Directional motion (flow) of the fuel at burn also impacts broadening and will lead to artificially inflated "Tion" values. Flow due to low-mode asymmetries is expected to give rise to line-of-sight variations in measured Tion. We report on intentionally asymmetrically driven experiments at the OMEGA laser facility designed to test the ability to accurately predict and measure line-of-sight differences in apparent Tion due to low-mode asymmetry-seeded flows. Contrasted to chimera and xrage simulations, the measurements demonstrate how all asymmetry seeds have to be considered to fully capture the flow field in an implosion. In particular, flow induced by the stalk that holds the target is found to interfere with the seeded asymmetry. A substantial stalk-seeded asymmetry in the areal density of the implosion is also observed

    Impact of stalk on directly driven inertial confinement fusion implosions

    Get PDF
    Low-mode asymmetries have emerged as one of the primary challenges to achieving high-performing inertial confinement fusion (ICF) implosions. In direct-drive ICF, an important potential seed of such asymmetries is the capsule stalk mount, the impact of which has remained a contentious question. In this paper, we describe the results from an experiment on the OMEGA laser with intentional offsets at varying angles to the capsule stalk mount, which clearly demonstrates the impact of the stalk mount on implosion dynamics. The angle between stalk and offset is found to significantly impact observables. Specifically, a larger directional flow is observed in neutron spectrum measurements when the offset is toward rather than away from the stalk, while an offset at 42° to the stalk gives minimal directional flow but still generates a large flow field in the implosion. No significant directional flow is seen due to stalk only. Time-integrated x-ray images support these flow observations. A trend is also seen in implosion yield, with lower yield obtained for offsets with a smaller angle than with a larger angle toward the stalk. Radiation hydrodynamic simulations using 2D DRACO and 2D/3D Chimera not including the stalk mount and using 2D xRAGE including the stalk mount are brought to bear on the data. The yield trend, the minimal directional flow with stalk only, and the larger flow enhancement observed with the offset toward the stalk are all reproduced in the xRAGE simulations. The results strongly indicate that the stalk impact must be considered and mitigated to achieve high-performing implosions

    Effect of strongly magnetized electrons and Ions on heat flow and symmetry of inertial fusion implosions

    Get PDF
    This Letter presents the first observation on how a strong, 500 kG, externally applied B field increases the mode-two asymmetry in shock-heated inertial fusion implosions. Using a direct-drive implosion with polar illumination and imposed field, we observed that magnetization produces a significant increase in the implosion oblateness (a 2.5 × larger P 2 amplitude in x-ray self-emission images) compared with reference experiments with identical drive but with no field applied. The implosions produce strongly magnetized electrons ( ω e τ e ≫ 1 ) and ions ( ω i τ i > 1 ) that, as shown using simulations, restrict the cross field heat flow necessary for lateral distribution of the laser and shock heating from the implosion pole to the waist, causing the enhanced mode-two shape

    Lawson criterion for ignition exceeded in an inertial fusion experiment

    Get PDF
    For more than half a century, researchers around the world have been engaged in attempts to achieve fusion ignition as a proof of principle of various fusion concepts. Following the Lawson criterion, an ignited plasma is one where the fusion heating power is high enough to overcome all the physical processes that cool the fusion plasma, creating a positive thermodynamic feedback loop with rapidly increasing temperature. In inertially confined fusion, ignition is a state where the fusion plasma can begin "burn propagation" into surrounding cold fuel, enabling the possibility of high energy gain. While "scientific breakeven" (i.e., unity target gain) has not yet been achieved (here target gain is 0.72, 1.37 MJ of fusion for 1.92 MJ of laser energy), this Letter reports the first controlled fusion experiment, using laser indirect drive, on the National Ignition Facility to produce capsule gain (here 5.8) and reach ignition by nine different formulations of the Lawson criterion

    Phased plan for the implementation of the time-resolving magnetic recoil spectrometer on the National Ignition Facility (NIF)

    No full text
    The time-resolving magnetic recoil spectrometer (MRSt) is a transformative diagnostic that will be used to measure the time-resolved neutron spectrum from an inertial confinement fusion implosion at the National Ignition Facility (NIF). It uses a CD foil on the outside of the hohlraum to convert fusion neutrons to recoil deuterons. An ion-optical system positioned outside the NIF target chamber energy-disperses and focuses forward-scattered deuterons. A pulse-dilation drift tube (PDDT) subsequently dilates, un-skews, and detects the signal. While the foil and ion-optical system have been designed, the PDDT requires more development before it can be implemented. Therefore, a phased plan is presented that first uses the foil and ion-optical systems with detectors that can be implemented immediately—namely CR-39 and hDISC streak cameras. These detectors will allow the MRSt to be commissioned in an intermediate stage and begin collecting data on a reduced timescale, while the PDDT is developed in parallel. A CR-39 detector will be used in phase 1 for the measurement of the time-integrated neutron spectra with excellent energy-resolution, necessary for the energy calibration of the system. Streak cameras will be used in phase 2 for measurement of the time-resolved spectrum with limited spectral coverage, which is sufficient to diagnose the time-resolved ion temperature. Simulations are presented that predict the performance of the streak camera detector, indicating that it will achieve excellent burn history measurements at current yields, and good time-resolved ion-temperature measurements at yields above 3 × 1017. The PDDT will be used for optimal efficiency and resolution in phase 3. </jats:p

    Knock-on deuteron imaging for diagnosing the morphology of an ICF implosion at OMEGA

    No full text
    Knock-on deuteron imaging is a new diagnostic technique that is being implemented at the OMEGA laser facility to diagnose the morphology of an inertial confinement fusion (ICF) implosion. It utilizes the fact that some of the neutrons from deuterium–tritium (DT)-fusion reactions generated in the central hot-spot of an ICF implosion elastically scatter deuterons as they traverse the surrounding shell layer. The energy of these “knock-on” deuterons depends on the scattering angle, where the most energetic deuterons are forward-scattered and probe the shape of the central hot-spot, while lower-energy deuterons are made by side-scattering or slowing down in the fuel and carry information about the distribution of the dense DT-fuel layer surrounding the hot-spot. The first proof-of-concept tests have been conducted successfully. In these tests, three penumbral imagers with different views on an implosion recorded deuterons scattered from the dense shell of DT-gas-filled deuterated plastic shell implosions with prescribed offsets. Data from these experiments are presented here, along with novel analysis techniques that iteratively reconstruct the deuteron source from the data. Reconstructed hot-spot and shell radii agree with 1D hydro simulations and indicate a P1 asymmetry in the direction of the offset. A comparison of coaxial deuteron and x-ray images suggests the presence of a mix between the hot-spot and shell on the order of 15  μm. This new diagnostic capability will allow us to study asymmetries in unprecedented detail at OMEGA. </jats:p

    Fast-ignition target design and experimental-concept validation on OMEGA

    No full text
    A comprehensive scientific program is being pursued at LLE to explore the physics of fast ignition. The OMEGA EP Laser was completed in April 2008, adjacent to the 60 beam, 30 kJ OMEGA Laser Facility. OMEGA EP consists of four beamlines with a NIF-like architecture, each delivering up to 6.5 kJ of UV laser energy in long pulse (ns) mode into the OMEGA EP target chamber. Two of the beamlines can operate as high-energy petawatt lasers, with up to 2.6 kJ each with 10 ps pulse duration. These beams can either be injected into the OMEGA EP target chamber or combined collinearly into the existing OMEGA target chamber for integrated fast-ignitor experiments. Fuel-assembly experiments on OMEGA have achieved high fuel areal densities, and the effects of a cone on the fuel assembly are being studied. Experiments on short-pulse laser systems in collaboration with other institutions are being pursued to investigate the conversion efficiency from laser energy to fast electrons. A coherent transition radiation diagnostic to study the transport of the electrons in high-density material is being developed. Integrated experiments with room-temperature targets on OMEGA will be performed in 2008. Simulations of these integrated experiments show significant heating of up to 1 keV due to the hot electrons from the short-pulse laser. © 2008 IOP Publishing Ltd

    X-ray-imaging spectrometer (XRIS) for studies of residual kinetic energy and low-mode asymmetries in inertial confinement fusion implosions at OMEGA (invited)

    No full text
    A system of x-ray imaging spectrometer (XRIS) has been implemented at the OMEGA Laser Facility and is capable of spatially and spectrally resolving x-ray self-emission from 5 to 40 keV. The system consists of three independent imagers with nearly orthogonal lines of sight for 3D reconstructions of the x-ray emission region. The distinct advantage of the XRIS system is its large dynamic range, which is enabled by the use of tantalum apertures with radii ranging from 50 μm to 1 mm, magnifications of 4 to 35×, and image plates with any filtration level. In addition, XRIS is capable of recording 1–100’s images along a single line of sight, facilitating advanced statistical inference on the detailed structure of the x-ray emitting regions. Properties such as P0 and P2 of an implosion are measured to 1% and 10% precision, respectively. Furthermore, T e can be determined with 5% accuracy. </jats:p

    In situ calibration of charged particle spectrometers on the OMEGA Laser Facility using 241Am and 226Ra sources

    No full text
    Charged particle spectrometry is a critical diagnostic to study inertial-confinement-fusion plasmas and high energy density plasmas. The OMEGA Laser Facility has two fixed magnetic charged particle spectrometers (CPSs) to measure MeV-ions. In situ calibration of these spectrometers was carried out using 241Am and 226Ra alpha emitters. The alpha emission spectrum from the sources was measured independently using surface-barrier detectors (SBDs). The energy dispersion and broadening of the CPS systems were determined by comparing the CPS measured alpha spectrum to that of the SBD. The calibration method significantly constrains the energy dispersion, which was previously obtained through the measurement of charged particle fusion products. Overall, a small shift of 100 keV was observed between previous and the calibration done in this work. </jats:p
    corecore