6 research outputs found

    Winter Time Concentrations and Size Distribution of Bioaerosols in Different Residential Settings in the UK

    Get PDF
    The total concentration and size distribution of bioaerosols in three different types of housing (single room in shared accommodation [type I], single bedroom flat in three-storey building [type II] and two- or threebedroom detached houses [type III]) was assessed during the winter. This research was an extension of a previous study carried out in the summer. The measurement campaign was undertaken in winter 2008 and 30 houses were sampled. Samples were taken from kitchens, living rooms, corridors (only in housing type I) and outdoors with an Anderson 6 stage viable impactor. In housing type I, the total geometric mean concentration was highest in the corridor for both bacteria and fungi (3,171 and 1,281 CFU/m3, respectively). In type II residences, both culturable bacteria and fungi were greatest in the living rooms (3,487 and 833 CFU/m3, respectively). The living rooms in type III residences had largest number of culturable bacteria (1,361 CFU/m3) while fungi were highest in kitchens (280 CFU/m3). The concentrations of culturable bacteria and fungi were greater in mouldy houses than non-mouldy houses. A considerable variation was seen in the size distribution of culturable bacteria in type I residences compared to types II and III. For all housing types more than half of culturable bacterial and fungal aerosol were respirable (<4.7 μm) and so have the potential to penetrate into lower respiratory system. Considerable variation in concentration and size distribution within different housing types in the same geographical region highlights the impact of differences in design, construction, use and management of residential built environment on bioaerosols levels and consequent varied risk of population exposure to airborne biological agents. © Springer Science+Business Media B.V. 2012

    Assessment of Bacterial and Fungal Aerosol in Different Residential Settings

    No full text
    The concentration and size distribution of bacterial and fungal aerosol was studied in 15 houses. The houses were categorized into three types, based on occupant density and number of rooms: single room in shared accommodation (type I), single bedroom flat in three storey buildings (type II) and two or three bedroomed houses (type III). Sampling was undertaken with an Anderson six-stage impactor during the summer of 2007 in the living rooms of all the residential settings. The maximum mean geometric concentration of bacterial (5,036 CFU/m3, ± 2.5, n∈=∈5) and fungal (2,124 CFU/m 3, ± 1.38, n∈=∈5) aerosol were in housing type III. The minimum levels of indoor culturable bacteria (1,557 CFU/m3, ±1.5, n∈=∈5) and fungal (925 CFU/m3, ±2.9, n∈=∈5) spores were observed in housing type I. The differences in terms of total bacterial and fungal concentration were less obvious between housing types I and II as compared to type III. With reference to size distribution, the dominant stages for culturable bacteria in housing types I, II and III were stage 3 (3.3-4.7 μm), stage 1 (7 μm and above) and stage 5 (1.1-2.1 μm), respectively. Whereas the maximum numbers of culturable fungal spores were recovered from stage 2 (4.7-7 μm), in housing type I, and from stage 4 (2.1-3.3 μm) in both type II and III houses. The average geometric mean diameter of bacterial aerosol was largest in type I (4.7 μm), followed by type II (3.89 μm) and III (1.96 μm). Similarly, for fungal spores, type I houses had the highest average mean geometric diameter (4.5 μm), while in types II and III the mean geometric diameter was 3.57 and 3.92 μm, respectively. The results indicate a wide variation in total concentration and size of bioaerosols among different residential settings. The observed differences in the size distributions and concentrations reflect their variable airborne behaviour and, as a result, different risks of respiratory exposure of the occupants to bioaerosols in various residential settings. © 2010 Springer Science+Business Media B.V
    corecore