148 research outputs found

    Boron microlocalization in oral mucosal tissue: implications for boron neutron capture therapy

    Get PDF
    Clinical studies of the treatment of glioma and cutaneous melanoma using boron neutron capture therapy (BNCT) are currently taking place in the USA, Europe and Japan. New BNCT clinical facilities are under construction in Finland, Sweden, England and California. The observation of transient acute effects in the oral mucosa of a number of glioma patients involved in the American clinical trials, suggests that radiation damage of the oral mucosa could be a potential complication in future BNCT clinical protocols, involving higher doses and larger irradiation field sizes. The present investigation is the first to use a high resolution surface analytical technique to relate the microdistribution of boron-10 (10B) in the oral mucosa to the biological effectiveness of the 10B(n,α)7Li neutron capture reaction in this tissue. The two boron delivery agents used clinically in Europe/Japan and the USA, borocaptate sodium (BSH) and p-boronophenylalanine (BPA), respectively, were evaluated using a rat ventral tongue model. 10B concentrations in various regions of the tongue mucosa were estimated using ion microscopy. In the epithelium, levels of 10B were appreciably lower after the administration of BSH than was the case after BPA. The epithelium:blood 10B partition ratios were 0.2:1 and 1:1 for BSH and BPA respectively. The 10B content of the lamina propria was higher than that measured in the epithelium for both BSH and BPA. The difference was most marked for BSH, where 10B levels were a factor of six higher in the lamina propria than in the epithelium. The concentration of 10B was also measured in blood vessel walls where relatively low levels of accumulation of BSH, as compared with BPA, was demonstrated in blood vessel endothelial cells and muscle. Vessel wall:blood 10B partition ratios were 0.3:1 and 0.9:1 for BSH and BPA respectively. Evaluation of tongue mucosal response (ulceration) to BNC irradiation indicated a considerably reduced radiation sensitivity using BSH as the boron delivery agent relative to BPA. The compound biological effectiveness (CBE) factor for BSH was estimated at 0.29 ± 0.02. This compares with a previously published CBE factor for BPA of 4.87 ± 0.16. It was concluded that variations in the microdistribution profile of 10B, using the two boron delivery agents, had a significant effect on the response of oral mucosa to BNC irradiation. From a clinical perspective, based on the findings of the present study, it is probable that potential radiation-induced oral mucositis will be restricted to BNCT protocols involving BPA. However, a thorough high resolution analysis of 10B microdistribution in human oral mucosal tissue, using a technique such as ion microscopy, is a prerequisite for the use of experimentally derived CBE factors in clinical BNCT. © 2000 Cancer Research Campaig

    Can standardized patients replace physicians as OSCE examiners?

    Get PDF
    BACKGROUND: To reduce inter-rater variability in evaluations and the demand on physician time, standardized patients (SP) are being used as examiners in OSCEs. There is concern that SP have insufficient training to provide valid evaluation of student competence and/or provide feedback on clinical skills. It is also unknown if SP ratings predict student competence in other areas. The objectives of this study were: to examine student attitudes towards SP examiners; to compare SP and physician evaluations of competence; and to compare predictive validity of these scores, using performance on the multiple choice questions examination (MCQE) as the outcome variable. METHODS: This was a cross-sectional study of third-year medical students undergoing an OSCE during the Internal Medicine clerkship rotation. Fifty-two students rotated through 8 stations (6 physician, 2 SP examiners). Statistical tests used were Pearson's correlation coefficient, two-sample t-test, effect size calculation, and multiple linear regression. RESULTS: Most students reported that SP stations were less stressful, that SP were as good as physicians in giving feedback, and that SP were sufficiently trained to judge clinical skills. SP scored students higher than physicians (mean 90.4% +/- 8.9 vs. 82.2% +/- 3.7, d = 1.5, p < 0.001) and there was a weak correlation between the SP and physician scores (coefficient 0.4, p = 0.003). Physician scores were predictive of summative MCQE scores (regression coefficient = 0.88 [0.15, 1.61], P = 0.019) but there was no relationship between SP scores and summative MCQE scores (regression coefficient = -0.23, P = 0.133). CONCLUSION: These results suggest that SP examiners are acceptable to medical students, SP rate students higher than physicians and, unlike physician scores, SP scores are not related to other measures of competence

    The Dreyfus model of clinical problem-solving skills acquisition: a critical perspective

    Get PDF
    Context: The Dreyfus model describes how individuals progress through various levels in their acquisition of skills and subsumes ideas with regard to how individuals learn. Such a model is being accepted almost without debate from physicians to explain the &#x2018;acquisition&#x2019; of clinical skills. Objectives: This paper reviews such a model, discusses several controversial points, clarifies what kind of knowledge the model is about, and examines its coherence in terms of problem-solving skills. Dreyfus&#x2019; main idea that intuition is a major aspect of expertise is also discussed in some detail. Relevant scientific evidence from cognitive science, psychology, and neuroscience is reviewed to accomplish these aims. Conclusions: Although the Dreyfus model may partially explain the &#x2018;acquisition&#x2019; of some skills, it is debatable if it can explain the acquisition of clinical skills. The complex nature of clinical problem-solving skills and the rich interplay between the implicit and explicit forms of knowledge must be taken into consideration when we want to explain &#x2018;acquisition&#x2019; of clinical skills. The idea that experts work from intuition, not from reason, should be evaluated carefully

    Boron neutron capture therapy induces apoptosis of glioma cells through Bcl-2/Bax

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Boron neutron capture therapy (BNCT) is an alternative treatment modality for patients with glioma. The aim of this study was to determine whether induction of apoptosis contributes to the main therapeutic efficacy of BNCT and to compare the relative biological effect (RBE) of BNCT, γ-ray and reactor neutron irradiation.</p> <p>Methods</p> <p>The neutron beam was obtained from the Xi'an Pulsed Reactor (XAPR) and γ-rays were obtained from [<sup>60</sup>Co] γ source of the Fourth Military Medical University (FMMU) in China. Human glioma cells (the U87, U251, and SHG44 cell lines) were irradiated by neutron beams at the XAPR or [<sup>60</sup>Co] γ-rays at the FMMU with different protocols: Group A included control nonirradiated cells; Group B included cells treated with 4 Gy of [<sup>60</sup>Co] γ-rays; Group C included cells treated with 8 Gy of [<sup>60</sup>Co] γ-rays; Group D included cells treated with 4 Gy BPA (p-borono-phenylalanine)-BNCT; Group E included cells treated with 8 Gy BPA-BNCT; Group F included cells irradiated in the reactor for the same treatment period as used for Group D; Group G included cells irradiated in the reactor for the same treatment period as used for Group E; Group H included cells irradiated with 4 Gy in the reactor; and Group I included cells irradiated with 8 Gy in the reactor. Cell survival was determined using the 3-(4,5-dimethylthiazol-2-yl-2,5-diphenyltetrazolium (MTT) cytotoxicity assay. The morphology of cells was detected by Hoechst33342 staining and transmission electron microscope (TEM). The apoptosis rate was detected by flow cytometer (FCM). The level of Bcl-2 and Bax protein was measured by western blot analysis.</p> <p>Results</p> <p>Proliferation of U87, U251, and SHG44 cells was much more strongly inhibited by BPA-BNCT than by irradiation with [<sup>60</sup>Co] γ-rays (<it>P </it>< 0.01). Nuclear condensation was determined using both a fluorescence technique and electron microscopy in all cell lines treated with BPA-BNCT. Furthermore, the cellular apoptotic rates in Group D and Group E treated with BPA-BNCT were significantly higher than those in Group B and Group C irradiated by [<sup>60</sup>Co] γ-rays (<it>P </it>< 0.01). The clonogenicity of glioma cells was reduced by BPA-BNCT compared with cells treated in the reactor (Group F, G, H, I), and with the control cells (<it>P </it>< 0.01). Upon BPA-BNCT treatment, the Bax level increased in glioma cells, whereas Bcl-2 expression decreased.</p> <p>Conclusions</p> <p>Compared with ��-ray and reactor neutron irradiation, a higher RBE can be achieved upon treatment of glioma cells with BNCT. Glioma cell apoptosis induced by BNCT may be related to activation of Bax and downregulation of Bcl-2.</p

    Current Developments in Intraspinal Agents for Cancer and Noncancer Pain

    Get PDF
    Since the late 1980s, intrathecal (IT) analgesic therapy has improved, and implantable IT drug delivery devices have become increasingly sophisticated. Physicians and patients now have myriad more options for agents and their combination, as well as for refining their delivery. As recently as 2007, The Polyanalgesic Consensus Conference of expert panelists updated its algorithm for drug selection in IT polyanalgesia. We review this algorithm and the emerging therapy included. This article provides an update on newly approved as well as emerging IT agents and the advances in technology for their delivery

    Workplace-based assessment: effects of rater expertise

    Get PDF
    Traditional psychometric approaches towards assessment tend to focus exclusively on quantitative properties of assessment outcomes. This may limit more meaningful educational approaches towards workplace-based assessment (WBA). Cognition-based models of WBA argue that assessment outcomes are determined by cognitive processes by raters which are very similar to reasoning, judgment and decision making in professional domains such as medicine. The present study explores cognitive processes that underlie judgment and decision making by raters when observing performance in the clinical workplace. It specifically focuses on how differences in rating experience influence information processing by raters. Verbal protocol analysis was used to investigate how experienced and non-experienced raters select and use observational data to arrive at judgments and decisions about trainees’ performance in the clinical workplace. Differences between experienced and non-experienced raters were assessed with respect to time spent on information analysis and representation of trainee performance; performance scores; and information processing––using qualitative-based quantitative analysis of verbal data. Results showed expert-novice differences in time needed for representation of trainee performance, depending on complexity of the rating task. Experts paid more attention to situation-specific cues in the assessment context and they generated (significantly) more interpretations and fewer literal descriptions of observed behaviors. There were no significant differences in rating scores. Overall, our findings seemed to be consistent with other findings on expertise research, supporting theories underlying cognition-based models of assessment in the clinical workplace. Implications for WBA are discussed

    Regulation of peripheral blood flow in Complex Regional Pain Syndrome: clinical implication for symptomatic relief and pain management

    Get PDF
    Background. During the chronic stage of Complex Regional Pain Syndrome (CRPS), impaired microcirculation is related to increased vasoconstriction, tissue hypoxia, and metabolic tissue acidosis in the affected limb. Several mechanisms may be responsible for the ischemia and pain in chronic cold CPRS. Discussion. The diminished blood flow may be caused by either sympathetic dysfunction, hypersensitivity to circulating catecholamines, or endothelial dysfunction. The pain may be of neuropathic, inflammatory, nociceptive, or functional nature, or of mixed origin. Summary. The origin of the pain should be the basis of the symptomatic therapy. Since the difference in temperature between both hands fluctuates over time in cold CRPS, when in doubt, the clinician should prioritize the patient's report of a persistent cold extremity over clinical tests that show no difference. Future research should focus on developing easily applied methods for clinical use to differentiate between central and peripheral blood flow regulation disorders in individual patients

    Synchrotron radiation-based experimental determination of the optimal energy for cell radiotoxicity enhancement following photoelectric effect on stable iodinated compounds

    Get PDF
    This study was designed to experimentally evaluate the optimal X-ray energy for increasing the radiation energy absorbed in tumours loaded with iodinated compounds, using the photoelectric effect. SQ20B human cells were irradiated with synchrotron monochromatic beam tuned at 32.8, 33.5, 50 and 70 keV. Two cell treatments were compared to the control: cells suspended in 10 mg ml1 of iodine radiological contrast agent or cells pre-exposed with 10 mM of iodo-desoxyuridine (IUdR) for 48 h. Our radiobiological end point was clonogenic cell survival. Cells irradiated with both iodine compounds exhibited a radiation sensitisation enhancement. Moreover, it was energy dependent, with a maximum at 50 keV. At this energy, the sensitisation calculated at 10% survival was equal to 2.03 for cells suspended in iodinated contrast agent and 2.60 for IUdR. Cells pretreated with IUdR had higher sensitisation factors over the energy range than for those suspended in iodine contrast agent. Also, their survival curves presented no shoulder, suggesting complex lethal damages from Auger electrons. Our results confirm the existence of the 50 keV energy optimum for a binary therapeutic irradiation based on the presence of stable iodine in tumours and an external irradiation. Monochromatic synchrotron radiotherapy concept is hence proposed for increasing the differential effect between healthy and cancerous tissue irradiation
    corecore