49 research outputs found
Lymphatic mapping and sentinel node biopsy in gynecological cancers: a critical review of the literature
Although it does not have a long history of sentinel node evaluation (SLN) in female genital system cancers, there is a growing number of promising study results, despite the presence of some aspects that need to be considered and developed. It has been most commonly used in vulvar and uterine cervivcal cancer in gynecological oncology. According to these studies, almost all of which are prospective, particularly in cases where Technetium-labeled nanocolloid is used, sentinel node detection rate sensitivity and specificity has been reported to be 100%, except for a few cases. In the studies on cervical cancer, sentinel node detection rates have been reported around 80–86%, a little lower than those in vulva cancer, and negative predictive value has been reported about 99%. It is relatively new in endometrial cancer, where its detection rate varies between 50 and 80%. Studies about vulvar melanoma and vaginal cancers are generally case reports. Although it has not been supported with multicenter randomized and controlled studies including larger case series, study results reported by various centers around the world are harmonious and mutually supportive particularly in vulva cancer, and cervix cancer. Even though it does not seem possible to replace the traditional approaches in these two cancers, it is still a serious alternative for the future. We believe that it is important to increase and support the studies that will strengthen the weaknesses of the method, among which there are detection of micrometastases and increasing detection rates, and render it usable in routine clinical practice
New models and online calculator for predicting non-sentinel lymph node status in sentinel lymph node positive breast cancer patients
<p>Abstract</p> <p>Background</p> <p>Current practice is to perform a completion axillary lymph node dissection (ALND) for breast cancer patients with tumor-involved sentinel lymph nodes (SLNs), although fewer than half will have non-sentinel node (NSLN) metastasis. Our goal was to develop new models to quantify the risk of NSLN metastasis in SLN-positive patients and to compare predictive capabilities to another widely used model.</p> <p>Methods</p> <p>We constructed three models to predict NSLN status: recursive partitioning with receiver operating characteristic curves (RP-ROC), boosted Classification and Regression Trees (CART), and multivariate logistic regression (MLR) informed by CART. Data were compiled from a multicenter Northern California and Oregon database of 784 patients who prospectively underwent SLN biopsy and completion ALND. We compared the predictive abilities of our best model and the Memorial Sloan-Kettering Breast Cancer Nomogram (Nomogram) in our dataset and an independent dataset from Northwestern University.</p> <p>Results</p> <p>285 patients had positive SLNs, of which 213 had known angiolymphatic invasion status and 171 had complete pathologic data including hormone receptor status. 264 (93%) patients had limited SLN disease (micrometastasis, 70%, or isolated tumor cells, 23%). 101 (35%) of all SLN-positive patients had tumor-involved NSLNs. Three variables (tumor size, angiolymphatic invasion, and SLN metastasis size) predicted risk in all our models. RP-ROC and boosted CART stratified patients into four risk levels. MLR informed by CART was most accurate. Using two composite predictors calculated from three variables, MLR informed by CART was more accurate than the Nomogram computed using eight predictors. In our dataset, area under ROC curve (AUC) was 0.83/0.85 for MLR (n = 213/n = 171) and 0.77 for Nomogram (n = 171). When applied to an independent dataset (n = 77), AUC was 0.74 for our model and 0.62 for Nomogram. The composite predictors in our model were the product of angiolymphatic invasion and size of SLN metastasis, and the product of tumor size and square of SLN metastasis size.</p> <p>Conclusion</p> <p>We present a new model developed from a community-based SLN database that uses only three rather than eight variables to achieve higher accuracy than the Nomogram for predicting NSLN status in two different datasets. </p
A comprehensive overview of radioguided surgery using gamma detection probe technology
The concept of radioguided surgery, which was first developed some 60 years ago, involves the use of a radiation detection probe system for the intraoperative detection of radionuclides. The use of gamma detection probe technology in radioguided surgery has tremendously expanded and has evolved into what is now considered an established discipline within the practice of surgery, revolutionizing the surgical management of many malignancies, including breast cancer, melanoma, and colorectal cancer, as well as the surgical management of parathyroid disease. The impact of radioguided surgery on the surgical management of cancer patients includes providing vital and real-time information to the surgeon regarding the location and extent of disease, as well as regarding the assessment of surgical resection margins. Additionally, it has allowed the surgeon to minimize the surgical invasiveness of many diagnostic and therapeutic procedures, while still maintaining maximum benefit to the cancer patient. In the current review, we have attempted to comprehensively evaluate the history, technical aspects, and clinical applications of radioguided surgery using gamma detection probe technology