18 research outputs found
Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO
Liquid xenon time projection chambers are promising detectors to search for
neutrinoless double beta decay (0), due to their response
uniformity, monolithic sensitive volume, scalability to large target masses,
and suitability for extremely low background operations. The nEXO collaboration
has designed a tonne-scale time projection chamber that aims to search for
0 of \ce{^{136}Xe} with projected half-life sensitivity of
~yr. To reach this sensitivity, the design goal for nEXO is
1\% energy resolution at the decay -value (~keV).
Reaching this resolution requires the efficient collection of both the
ionization and scintillation produced in the detector. The nEXO design employs
Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm
scintillation light of liquid xenon. This paper reports on the characterization
of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3
SiPMs specifically designed for nEXO, as well as new measurements on new test
samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters
(MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct
crosstalk, correlated avalanches and photon detection efficiency were measured
as a function of the applied over voltage and wavelength at liquid xenon
temperature (163~K). The results from this study are used to provide updated
estimates of the achievable energy resolution at the decay -value for the
nEXO design
Development of a Xe calibration source for nEXO
International audienceWe study a possible calibration technique for the nEXO experiment using a Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay (0νββ) that will use a 5-tonne, monolithic liquid xenon time projection chamber (TPC). The xenon, used both as source and detection medium, will be enriched to 90% in Xe. To optimize the event reconstruction and energy resolution, calibrations are needed to map the position- and time-dependent detector response. The 36.3 day half-life of Xe and its small Q-value compared to that of Xe 0νββ would allow a small activity to be maintained continuously in the detector during normal operations without introducing additional backgrounds, thereby enabling in-situ calibration and monitoring of the detector response. In this work we describe a process for producing the source and preliminary experimental tests. We then use simulations to project the precision with which such a source could calibrate spatial corrections to the light and charge response of the nEXO TPC
Supernova Electron-Neutrino Interactions with Xenon in the nEXO Detector
International audienceElectron-neutrino charged-current interactions with xenon nuclei were modeled in the nEXO neutrinoless double-beta decay detector (~5-tonne, 90% Xe, 10% Xe) to evaluate its sensitivity to supernova neutrinos. Predictions for event rates and detectable signatures were modeled using the MARLEY event generator. We find good agreement between MARLEY's predictions and existing theoretical calculations of the inclusive cross sections at supernova neutrino energies. The interactions modeled by MARLEY were simulated within the nEXO simulation framework and were run through an example reconstruction algorithm to determine the detector's efficiency for reconstructing these events. The simulated data, incorporating the detector response, were used to study the ability of nEXO to reconstruct the incident electron-neutrino spectrum and these results were extended to a larger xenon detector of the same isotope enrichment. We estimate that nEXO will be able to observe electron-neutrino interactions with xenon from supernovae as far as 5 to 8 kpc from earth, while the ability to reconstruct incident electron-neutrino spectrum parameters from observed interactions in nEXO is limited to closer supernovae
Imaging of single barium atoms in a second matrix site in solid xenon for barium tagging in a Xe double beta decay experiment
International audienceNeutrinoless double beta decay is one of the most sensitive probes for new physics beyond the Standard Model of particle physics. One of the isotopes under investigation is Xe, which would double beta decay into Ba. Detecting the single Ba daughter provides a sort of ultimate tool in the discrimination against backgrounds. Previous work demonstrated the ability to perform single atom imaging of Ba atoms in a single-vacancy site of a solid xenon matrix. In this paper, the effort to identify signal from individual barium atoms is extended to Ba atoms in a hexa-vacancy site in the matrix and is achieved despite increased photobleaching in this site. Abrupt fluorescence turn-off of a single Ba atom is also observed. Significant recovery of fluorescence signal lost through photobleaching is demonstrated upon annealing of Ba deposits in the Xe ice. Following annealing, it is observed that Ba atoms in the hexa-vacancy site exhibit antibleaching while Ba atoms in the tetra-vacancy site exhibit bleaching. This may be evidence for a matrix site transfer upon laser excitation. Our findings offer a path of continued research toward tagging of Ba daughters in all significant sites in solid xenon
Imaging of single barium atoms in a second matrix site in solid xenon for barium tagging in a Xe double beta decay experiment
International audienceNeutrinoless double beta decay is one of the most sensitive probes for new physics beyond the Standard Model of particle physics. One of the isotopes under investigation is Xe, which would double beta decay into Ba. Detecting the single Ba daughter provides a sort of ultimate tool in the discrimination against backgrounds. Previous work demonstrated the ability to perform single atom imaging of Ba atoms in a single-vacancy site of a solid xenon matrix. In this paper, the effort to identify signal from individual barium atoms is extended to Ba atoms in a hexa-vacancy site in the matrix and is achieved despite increased photobleaching in this site. Abrupt fluorescence turn-off of a single Ba atom is also observed. Significant recovery of fluorescence signal lost through photobleaching is demonstrated upon annealing of Ba deposits in the Xe ice. Following annealing, it is observed that Ba atoms in the hexa-vacancy site exhibit antibleaching while Ba atoms in the tetra-vacancy site exhibit bleaching. This may be evidence for a matrix site transfer upon laser excitation. Our findings offer a path of continued research toward tagging of Ba daughters in all significant sites in solid xenon
Supernova Electron-Neutrino Interactions with Xenon in the nEXO Detector
International audienceElectron-neutrino charged-current interactions with xenon nuclei were modeled in the nEXO neutrinoless double-beta decay detector (~5-tonne, 90% Xe, 10% Xe) to evaluate its sensitivity to supernova neutrinos. Predictions for event rates and detectable signatures were modeled using the MARLEY event generator. We find good agreement between MARLEY's predictions and existing theoretical calculations of the inclusive cross sections at supernova neutrino energies. The interactions modeled by MARLEY were simulated within the nEXO simulation framework and were run through an example reconstruction algorithm to determine the detector's efficiency for reconstructing these events. The simulated data, incorporating the detector response, were used to study the ability of nEXO to reconstruct the incident electron-neutrino spectrum and these results were extended to a larger xenon detector of the same isotope enrichment. We estimate that nEXO will be able to observe electron-neutrino interactions with xenon from supernovae as far as 5 to 8 kpc from earth, while the ability to reconstruct incident electron-neutrino spectrum parameters from observed interactions in nEXO is limited to closer supernovae