167 research outputs found

    A practical approach for a patient-tailored dose protocol in coronary CT angiography using prospective ECG triggering

    Get PDF
    To derive and validate a practical patient-specific dose protocol to obtain an image quality, expressed by the image noise, independent of patients’ size and a better radiation dose justification in coronary CT angiography (CCTA) using prospective ECG triggering. 43 patients underwent clinically indicated CCTA. The image noise, defined as the standard deviation of pixel attenuation values in a homogeneous region in the liver, was determined in all scans. Subsequently, this noise was normalized to the radiation exposure. Next, three patient-specific parameters, body weight, body mass index and mass per length (MPL), were tested for the best correlation with normalized image noise. From these data, a new dose protocol to provide a less variable image noise was derived and subsequently validated in 84 new patients. The normalized image noise increased for heavier patients for all patients’ specific parameters (p < 0.001). MPL correlated best with the normalized image noise and was selected for dose protocol optimization. This new protocol resulted in image noise levels independent of patients’ MPL (p = 0.28). A practical method to obtain CCTA images with noise levels independent of patients’ MPL was derived and validated. It results in a less variable image quality and better radiation exposure justification and can also be used for CT scanners from other vendors

    Development and validation of a patient- tailored dose regime in myocardial perfusion imaging using conventional SPECT

    Get PDF
    Background\ud The decreasing image quality in heavier patients can be compensated by administration of a patient-specific dose in myocardial perfusion imaging (MPI) using a cadmium zinc telluride-based SPECT camera. Our aim was to determine if the same can be achieved when using a conventional SPECT camera.\ud \ud \ud Methods\ud 148 patients underwent SPECT stress MPI using a fixed Tc-99m tetrofosmin tracer dose. Measured photon counts were normalized to administered tracer dose and scan time and were correlated with body weight, body mass index, and mass per length to find the best predicting parameter. From these data, a protocol to provide constant image quality was derived, and subsequently validated in 125 new patients.\ud \ud \ud Results\ud Body weight was found to be the best predicting parameter for image quality and was used to derive a new dose formula; Aadmin (MBq) = 223·body weight (kg)0.65/Tscan (min). The measured photon counts decreased in heavier patients when using a fixed dose (P < .01) but this was no longer observed after applying a body-weight-dependent protocol (P = .20).\ud \ud \ud Conclusions\ud Application of a patient-specific protocol resulted in an image quality less depending on patient’s weight. The results are most likely independent of the type of SPECT camera used, and, hence, adoption of patient-specific dose and scan time protocols is recommended

    Pain management in patients with dementia

    Get PDF
    There are an estimated 35 million people with dementia across the world, of whom 50% experience regular pain. Despite this, current assessment and treatment of pain in this patient group are inadequate. In addition to the discomfort and distress caused by pain, it is frequently the underlying cause of behavioral symptoms, which can lead to inappropriate treatment with antipsychotic medications. Pain also contributes to further complications in treatment and care. This review explores four key perspectives of pain management in dementia and makes recommendations for practice and research. The first perspective discussed is the considerable uncertainty within the literature on the impact of dementia neuropathology on pain perception and processing in Alzheimer’s disease and other dementias, where white matter lesions and brain atrophy appear to influence the neurobiology of pain. The second perspective considers the assessment of pain in dementia. This is challenging, particularly because of the limited capacity of self-report by these individuals, which means that assessment relies in large part on observational methods. A number of tools are available but the psychometric quality and clinical utility of these are uncertain. The evidence for efficient treatment (the third perspective) with analgesics is also limited, with few statistically well-powered trials. The most promising evidence supports the use of stepped treatment approaches, and indicates the benefit of pain and behavioral interventions on both these important symptoms. The fourth perspective debates further difficulties in pain management due to the lack of sufficient training and education for health care professionals at all levels, where evidence-based guidance is urgently needed. To address the current inadequate management of pain in dementia, a comprehensive approach is needed. This would include an accurate, validated assessment tool that is sensitive to different types of pain and therapeutic effects, supported by better training and support for care staff across all settings

    Pain management in patients with dementia

    Get PDF
    There are an estimated 35 million people with dementia across the world, of whom 50% experience regular pain. Despite this, current assessment and treatment of pain in this patient group are inadequate. In addition to the discomfort and distress caused by pain, it is frequently the underlying cause of behavioral symptoms, which can lead to inappropriate treatment with antipsychotic medications. Pain also contributes to further complications in treatment and care. This review explores four key perspectives of pain management in dementia and makes recommendations for practice and research. The first perspective discussed is the considerable uncertainty within the literature on the impact of dementia neuropathology on pain perception and processing in Alzheimer’s disease and other dementias, where white matter lesions and brain atrophy appear to influence the neurobiology of pain. The second perspective considers the assessment of pain in dementia. This is challenging, particularly because of the limited capacity of self-report by these individuals, which means that assessment relies in large part on observational methods. A number of tools are available but the psychometric quality and clinical utility of these are uncertain. The evidence for efficient treatment (the third perspective) with analgesics is also limited, with few statistically well-powered trials. The most promising evidence supports the use of stepped treatment approaches, and indicates the benefit of pain and behavioral interventions on both these important symptoms. The fourth perspective debates further difficulties in pain management due to the lack of sufficient training and education for health care professionals at all levels, where evidence-based guidance is urgently needed. To address the current inadequate management of pain in dementia, a comprehensive approach is needed. This would include an accurate, validated assessment tool that is sensitive to different types of pain and therapeutic effects, supported by better training and support for care staff across all settings.publishedVersio

    Quality assurance of radiation therapy after breast-conserving surgery among patients in the BOOG 2013-08 trial

    Get PDF
    Background and purpose: In the BOOG 2013-08 trial (NCT02271828), cT1-2N0 breast cancer patients were randomized between breast conserving surgery with or without sentinel lymph node biopsy (SLNB) followed by whole breast radiotherapy (WBRT). While awaiting primary endpoint results (axillary recurrence rate), this study aims to perform a quality assurance analysis on protocol adherence and (incidental) axillary radiation therapy (RT) dose. Materials and methods: Patients were enrolled between 2015 and 2022. Data on prescribed RT and (in 25% of included patients) planning target volumes (PTV) parameters were recorded for axillary levels I-IV and compared between treatment arms. Multivariable linear regression analysis was performed to determine prognostic variables for incidental axillary RT dose. Results: 1,439/1,461 included patients (98.5%) were treated according to protocol and 87 patients (5.9%) received regional RT (SLNB 10.9%, no-SLNB 1.5 %). In 326 patients included in the subgroup analysis, the mean incidental PTV dose at axilla level I was 59.5% of the prescribed breast RT dose. In 5 patients (1.5%) the mean PTV dose at level I was ≥95% of the prescribed breast dose. No statistically or clinically significant differences regarding incidental axillary RT dose were found between treatment arms. Tumour bed boost (yes/no) was associated with a higher incidental mean dose in level I (R2 = 0.035, F(6, 263) = 1.532, p 0.168). Conclusion: The results indicate that RT-protocol adherence was high, and that incidental axillary RT dose was low in the BOOG 2013-08 trial. Potential differences between treatmentarms regarding the primary endpoint can thus not be attributed to different axillary radiation doses.</p

    Quality assurance of radiation therapy after breast-conserving surgery among patients in the BOOG 2013-08 trial

    Get PDF
    Background and purpose: In the BOOG 2013-08 trial (NCT02271828), cT1-2N0 breast cancer patients were randomized between breast conserving surgery with or without sentinel lymph node biopsy (SLNB) followed by whole breast radiotherapy (WBRT). While awaiting primary endpoint results (axillary recurrence rate), this study aims to perform a quality assurance analysis on protocol adherence and (incidental) axillary radiation therapy (RT) dose. Materials and methods: Patients were enrolled between 2015 and 2022. Data on prescribed RT and (in 25% of included patients) planning target volumes (PTV) parameters were recorded for axillary levels I-IV and compared between treatment arms. Multivariable linear regression analysis was performed to determine prognostic variables for incidental axillary RT dose. Results: 1,439/1,461 included patients (98.5%) were treated according to protocol and 87 patients (5.9%) received regional RT (SLNB 10.9%, no-SLNB 1.5 %). In 326 patients included in the subgroup analysis, the mean incidental PTV dose at axilla level I was 59.5% of the prescribed breast RT dose. In 5 patients (1.5%) the mean PTV dose at level I was ≥95% of the prescribed breast dose. No statistically or clinically significant differences regarding incidental axillary RT dose were found between treatment arms. Tumour bed boost (yes/no) was associated with a higher incidental mean dose in level I (R2 = 0.035, F(6, 263) = 1.532, p 0.168). Conclusion: The results indicate that RT-protocol adherence was high, and that incidental axillary RT dose was low in the BOOG 2013-08 trial. Potential differences between treatmentarms regarding the primary endpoint can thus not be attributed to different axillary radiation doses.</p

    Wholesale pricing in a small open economy

    Get PDF
    This paper addresses the empirical analysis of wholesale profit margins using data of the Dutch wholesale sector, 1986. At the heart of the analysis is the typical nature of wholesale production: wholesalers do not produce a tangible product, but offer a service capacity. This has an immediate impact on the identification, interprelation and measurement of determinants of profit variations. A model is set up to explain variations in wholesale profit margins, which is inspired by two widely applied approaches to industry pricing: the behavioural mark-up model and the marginalist price-cost model

    Measurement of charged-particle multiplicity distributions and their H_q moments in hadronic Z decays at LEP

    Get PDF
    The charged-particle multiplicity distribution is measured for all hadronic events as well as for light-quark and b-quark events produced in e+e- collisions at the Z pole. Moments of the charged-particle multiplicity distributions are calculated. The H moments of the multiplicity distributions are studied, and their quasi-oscillations as a function of the rank of the moment are investigated.Comment: Matches published versio

    Bose-Einstein Correlations of Neutral and Charged Pions in Hadronic Z Decays

    Get PDF
    Bose-Einstein correlations of both neutral and like-sign charged pion pairs are measured in a sample of 2 million hadronic Z decays collected with the L3 detector at LEP. The analysis is performed in the four-momentum difference range 300 MeV < Q < 2 GeV. The radius of the neutral pion source is found to be smaller than that of charged pions. This result is in qualitative agreement with the string fragmentation model
    corecore